FCC ID MTF052651

Desktop PCS Transceiver - Phonecell

by Telular Corporation

Grantee Code: MTF   Product Code: 052651
Latest application date: 2002-05-28

FCC ID Device Details

FCC IDMTF052651
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMTF
Product Code052651
Applicant BusinessTelular Corporation 🇺🇸
Related Domains telular.com metlabs.com
Equipment ClassDesktop PCS Transceiver - Phonecell
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.4-1909.6 MHzOriginal Equipment2002-05-28

Exhibits

DocumentTypeAvailableFile
SX5D manualUsers Manual2002-05-28PDF 839.7 KB
SX5e manualUsers Manual2002-05-28PDF 579.1 KB
internal photosInternal Photos2002-05-28PDF 382.3 KB
external photoExternal Photos2002-05-28PDF 61 KB
label and locationID Label/Location Info2002-05-28PDF 1.4 MB
SX5D descriptionOperational Description2002-05-28PDF 98.3 KB
SX5e descriptionOperational Description2002-05-28PDF 84 KB
setup photoTest Setup Photos2002-05-28PDF 144.1 KB
revised test reportTest Report2002-05-28PDF 418.5 KB
test report Metadata onlyTest Report2002-05-28PDF 418.2 KB
authorization letterCover Letter(s)2002-05-28PDF 14.3 KB
confidentiality request Metadata onlyCover Letter(s)2002-05-28PDF 19.2 KB
revised confidentiality letterCover Letter(s)2002-05-28PDF 19.3 KB
MPE CalculationRF Exposure Info2002-05-28PDF 5.2 KB
schematics Metadata onlySchematicsPDF 369.8 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 113.9 KB

Application Information

Application IDFsCucqM94F11AIltWEfwTw==
Final Action Date2002-05-28
Application PurposeOriginal Equipment
Applicant FRN0003794716
Model052651
Frequency Range1850.4-1909.6 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionDesktop PCS Transceiver - Phonecell
Responsible PartyRaj Kosaraju, Director - Quality Assurance, rkosaraju@telular.com , 678-264-2012
AgentChris Chris Chris, MET Laboratories, Inc., charvey@metlabs.com , 410-354-3300
Technical ContactLiming Xu, MET Laboratories, Inc., lxu@metlabs.com , 410-354-3300
Non-Technical ContactMarianne Bosley, MET Laboratories, Inc., mbosley@metlabs.com , 410-354-3300
Test FirmJohn Mason, MET Laboratories, Inc., jmason@metlabs.com , 410-354-3300
TCB Emailcharvey@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe peak EIRP of this device is 1.6 Watts. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
FsCucqM94F11AIltWEfwTw==2002-05-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.4-1909.6 MHz0.857000050.0000000000Hz243KGXW24E20, BC

Grants

TCB Grant - Application FsCucqM94F11AIltWEfwTw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 05/28/2002

Application Dated: 05/28/2002
Telular Corporation
3225 Cumberland Blvd
Suite 300
Atlanta, GA 30339
 
Attention: Raj Kosaraju , Director - Quality Assurance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MTF052651
Name of Grantee:  Telular Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Desktop PCS Transceiver - Phonecell
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 BC 24E 1850.4  -  1909.6 0.857 50.0  Hz 243KGXW

The peak EIRP of this device is 1.6 Watts. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.
BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application FsCucqM94F11AIltWEfwTw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Telular Corporation
3225 Cumberland Blvd Suite 300
Atlanta, GA 30339
United States
  Date of Grant: 05/28/2002

Application Dated: 05/28/2002
 
Attention: Raj Kosaraju , Director - Quality Assurance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MTF052651
Name of Grantee:  Telular Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Desktop PCS Transceiver - Phonecell
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 BC 24E 1850.4  -  1909.6 0.857 50.0  Hz 243KGXW

The peak EIRP of this device is 1.6 Watts. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.
BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: