FCC ID N52-ADXD-LPR

DAS (Distributed Antenna System)

by ADRF KOREA, Inc.

Grantee Code: N52   Product Code: ADXDLPR
Latest application date: 2021-04-12

FCC ID Device Details

FCC IDN52-ADXD-LPR
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeN52
Product CodeADXDLPR
Applicant BusinessADRF KOREA, Inc. 🇰🇷
Related Domains adrftech.com
Equipment ClassDAS (Distributed Antenna System)
Test FirmHCT Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
3550-3700 MHzOriginal Equipment2021-04-12
728-746 MHzOriginal Equipment2020-05-15

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2020-11-10PDF 4.4 MB
Internal PhotosInternal Photos2020-11-10PDF 1.3 MB
External PhotosExternal Photos2020-11-10PDF 614.4 KB
ID Label and Location InfoID Label/Location Info2020-05-15PDF 139.9 KB
Test Setup PhotosTest Setup Photos2020-11-10PDF 819.9 KB
MPE Test ReportRF Exposure Info2020-05-15PDF 1 MB
RF Test Report - 1 of 7Test Report2020-05-15PDF 5.3 MB
RF Test Report - 2 of 7Test Report2020-05-15PDF 4.2 MB
RF Test Report - 3 of 7Test Report2020-05-15PDF 4.3 MB
RF Test Report - 4 of 7Test Report2020-05-15PDF 5.6 MB
RF Test Report - 5 of 7Test Report2020-05-15PDF 5.6 MB
RF Test Report - 6 of 7Test Report2020-05-15PDF 5.9 MB
RF Test Report - 7 of 7Test Report2020-05-15PDF 4.9 MB
Attestation letter for Warning Label Message_Part 20Attestation Statements2020-05-15PDF 267.5 KB
Agent Authorization LetterCover Letter(s)2020-05-15PDF 338.7 KB
Confidentiality Request LetterCover Letter(s)2020-05-15PDF 283.5 KB
Dismissal Request CBD GrantCover Letter(s)PDF 25.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 722.4 KB
Schematic Metadata onlySchematicsPDF 5.3 MB
OP - Ant Spec_700_800_PCS_ASW Metadata onlyOperational DescriptionPDF 136.5 KB
OP - Ant Spec_BRS_CBRS Metadata onlyOperational DescriptionPDF 135.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 2 MB
Operational Description - Ant Spec_700_800_PCS_ASW Metadata onlyOperational DescriptionPDF 136.5 KB
Operational Description - Ant Spec_BRS_CBRS Metadata onlyOperational DescriptionPDF 135.5 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 351 KB
Tune Up Info Metadata onlyParts List/Tune Up InfoPDF 385.7 KB

Application Information

Application IDozkmhqXO11wyn9TqJuPIMQ==
Final Action Date2021-04-12
Application PurposeOriginal Equipment
Applicant FRN0021709860
ModelADXD-LPR
Frequency Range3550-3700 MHz
Equipment ClassCBD - Citizens Band Category A and B Devices
Device DescriptionDAS (Distributed Antenna System)
Responsible PartyHyun-Kyung Song, Management Support Team Manager, hk4464@adrftech.com , +82-31-637-4435
Test FirmLee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr , 82-31-645-6432
TCB Emailtcb@hctamerica.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/10/2020
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsReissued by FCC

Applications

Application IDDatePurpose
ozkmhqXO11wyn9TqJuPIMQ==2021-04-12Original Equipment
oV++cirhB0S5FD6Ch2qLyw==2020-05-15Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
728-746 MHz0.068AmpG7W27
746-757 MHz0.068AmpG7W27
862-869 MHz0.069AmpG7W90S
869-894 MHz0.068AmpG7W22H
1930-1995 MHz0.104AmpG7W24E
2110-2155 MHz0.106AmpG7W27
2496-2690 MHz0.091AmpG7W27
2496-2690 MHz0.093AmpG7W27
3550-3700 MHz0.043Amp78M0G7W96
3550-3700 MHz0.038Amp18M0G7W96

Grants

TCB Grant - Application ozkmhqXO11wyn9TqJuPIMQ==

This application does not exist.

EAS Grant - Application ozkmhqXO11wyn9TqJuPIMQ==

This application currently is not in final status.

TCB Grant - Application oV++cirhB0S5FD6Ch2qLyw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 05/15/2020

Application Dated: 05/15/2020
ADRF KOREA, Inc.
5-5, Mojeon-Ri, Backsa-Myun, Icheon-City,
Kyunggi-Do,,
South Korea
 
Attention: Hyun-Kyung Song , Management Support Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N52-ADXD-LPR
Name of Grantee:  ADRF KOREA, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: DAS (Distributed Antenna System)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 728.0  -  746.0 0.068  Amp G7W
27 746.0  -  757.0 0.068  Amp G7W
90S 862.0  -  869.0 0.069  Amp G7W
22H 869.0  -  894.0 0.068  Amp G7W
24E 1930.0  -  1995.0 0.104  Amp G7W
27 2110.0  -  2155.0 0.106  Amp G7W
27 2496.0  -  2690.0 0.091  Amp G7W
27 2496.0  -  2690.0 0.093  Amp G7W

In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.426 Watts. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 8 dBi with minimum separation distance 100 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules.

EAS Grant - Application oV++cirhB0S5FD6Ch2qLyw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ADRF KOREA, Inc.
5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, P.O. Box ,
Kyunggi-Do,,
South Korea
  Date of Grant: 05/15/2020

Application Dated: 05/15/2020
 
Attention: Hyun-Kyung Song , Management Support Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N52-ADXD-LPR
Name of Grantee:  ADRF KOREA, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: DAS (Distributed Antenna System)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 728.0  -  746.0 0.068  Amp G7W
27 746.0  -  757.0 0.068  Amp G7W
90S 862.0  -  869.0 0.069  Amp G7W
22H 869.0  -  894.0 0.068  Amp G7W
24E 1930.0  -  1995.0 0.104  Amp G7W
27 2110.0  -  2155.0 0.106  Amp G7W
27 2496.0  -  2690.0 0.091  Amp G7W
27 2496.0  -  2690.0 0.093  Amp G7W

In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.426 Watts. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 8 dBi with minimum separation distance 100 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules.



Mail To: