FCC ID N52-ADXV-R-339P
DAS
by ADRF KOREA, Inc.
Grantee Code: N52 Product Code: ADXVR339P
Latest application date: 2021-11-05
FCC ID Device Details
| FCC ID | N52-ADXV-R-339P |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | N52 |
| Product Code | ADXVR339P |
| Applicant Business | ADRF KOREA, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | DAS |
| Test Firm | HCT Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 930-931 MHz | Class II permissive change or modification of presently authorized equipment | 2021-11-05 |
| 930-931 MHz | Original Equipment | 2020-09-10 |
| 929-930 MHz | Original Equipment | 2020-09-10 |
| 928-929 MHz | Original Equipment | 2020-09-10 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-05-04 | PDF 4.3 MB |
| ID Label and Location Info | ID Label/Location Info | 2020-09-10 | PDF 257 KB |
| Test Setup Photo | Test Setup Photos | 2022-05-04 | PDF 1 MB |
| Test Report | Test Report | 2021-11-05 | PDF 1.7 MB |
| MPE Test Report | RF Exposure Info | 2020-09-10 | PDF 351.4 KB |
| RF Test Report - 1 of 3 | Test Report | 2020-09-10 | PDF 5.5 MB |
| RF Test Report - 2 of 3 | Test Report | 2020-09-10 | PDF 5.4 MB |
| RF Test Report - 3 of 3 | Test Report | 2020-09-10 | PDF 1.2 MB |
| Attestation Letter for Warning | Attestation Statements | 2021-11-05 | PDF 119.3 KB |
| Attestation letter for Warning Label Message | Attestation Statements | 2020-09-10 | PDF 257.1 KB |
| Agent Authorization Letter | Cover Letter(s) | 2021-11-05 | PDF 726.3 KB |
| C2PC Letter | Cover Letter(s) | 2021-11-05 | PDF 483.5 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2021-11-05 | PDF 653.4 KB |
| Agent Authorization Letter | Cover Letter(s) | 2020-09-10 | PDF 677.7 KB |
| Confidential Request Letter | Cover Letter(s) | 2020-09-10 | PDF 515.2 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2020-09-10 | PDF 515.2 KB |
| RF Exposure Report | RF Exposure Info | 2021-11-05 | PDF 311.2 KB |
| Operational Description Metadata only | Operational Description | PDF 1.3 MB | |
| Tune-up Procedure Metadata only | Parts List/Tune Up Info | PDF 284.7 KB |
Application Information
| Application ID | Vnq93n9hL46CyPge1q/j5A== |
|---|---|
| Final Action Date | 2021-11-05 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0021709860 |
| Model | ADXV-R-339P |
| Frequency Range | 930-931 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | DAS |
| Responsible Party | Hyun-Kyung Song, Management Support Team Manager, hk4464@adrftech.com |
| Test Firm | Lee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr |
| TCB Email | TCB@hctamerica.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 05/04/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change to add LTE operation. DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Vnq93n9hL46CyPge1q/j5A== | 2021-11-05 | Class II permissive change or modification of presently authorized equipment |
| wv1QJbQ8rleOUBTOflqepg== | 2020-09-10 | Original Equipment |
| cQ9tUQKhciBMDRgzM36ofw== | 2020-09-10 | Original Equipment |
| SIrG7wDZ+AxAjsFW5Wb5kA== | 2020-09-10 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 928-929 MHz | 2.193 | Amp | F1D | 101 |
| 928-929 MHz | 2.056 | Amp | F1D | 101 |
| 929-930 MHz | 2.109 | Amp | F1D | 9 |
| 929-930 MHz | 1.892 | Amp | F1D | 9 |
| 929-930 MHz | 2.109 | Amp | F2D | 9 |
| 930-931 MHz | 2.109 | Amp | F1D | 24D |
| 930-931 MHz | 2.061 | Amp | F1D | 24D |
| 930-931 MHz | 1.892 | Amp | F1D | 24D |
| 930-931 MHz | 2.183 | Amp | F1D | 24D |
| 931-932 MHz | 2.061 | Amp | F1D | 22 |
| 931-932 MHz | 2.056 | Amp | F1D | 22 |
| 931-932 MHz | 2.183 | Amp | F1D | 22 |
| 931-932 MHz | 2.009 | Amp | F1D | 22 |
| 932-935 MHz | 1.919 | Amp | F1D | 101 |
| 932-935 MHz | 2.009 | Amp | F1D | 101 |
| 935-940 MHz | 1.823 | Amp | F1D | 90S |
| 935-940 MHz | 2.007 | Amp | F1D | 90S |
| 935-940 MHz | 2.007 | Amp | F2D | 90S |
| 935-940 MHz | 1.892 | Amp | F2D | 90S |
| 936.5-939.5 MHz | 1.56 | Amp | G7W | 27 |
| 940-941 MHz | 1.919 | Amp | F1D | 24D |
| 940-941 MHz | 2.009 | Amp | F1D | 24D |
| 940-941 MHz | 2.193 | Amp | F1D | 24D |
| 940-941 MHz | 2.056 | Amp | F1D | 24D |
Grants
TCB Grant - Application wv1QJbQ8rleOUBTOflqepg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| ADRF KOREA, Inc. |
| 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, |
| Kyunggi-Do,, South Korea |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 2.061 | Amp | F1D | |
| 24D | 930.0 - 931.0 | 2.183 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.056 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.009 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.823 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 2.007 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.193 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.056 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.892 | Amp | F2D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
EAS Grant - Application wv1QJbQ8rleOUBTOflqepg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ADRF KOREA, Inc. 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, P.O. Box , Kyunggi-Do,, South Korea |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 2.061 | Amp | F1D | |
| 24D | 930.0 - 931.0 | 2.183 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.056 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.009 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.823 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 2.007 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.193 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.056 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.892 | Amp | F2D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 11/05/2021 Application Dated: 11/05/2021 |
| ADRF KOREA, Inc. |
| 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, |
| Kyunggi-Do,, South Korea |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 2.109 | Amp | F1D | |
| 24D | 930.0 - 931.0 | 1.892 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.061 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.183 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 1.919 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.009 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 2.007 | Amp | F2D | |
| 27 | 936.5 - 939.5 | 1.56 | Amp | G7W |
| Class II Permissive Change to add LTE operation. DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
EAS Grant - Application Vnq93n9hL46CyPge1q/j5A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ADRF KOREA, Inc. 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, P.O. Box , Kyunggi-Do,, South Korea |
Date of Grant: 11/05/2021 Application Dated: 11/05/2021 |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 2.109 | Amp | F1D | |
| 24D | 930.0 - 931.0 | 1.892 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.061 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 2.183 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 1.919 | Amp | F1D | |
| 24D | 940.0 - 941.0 | 2.009 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 2.007 | Amp | F2D | |
| 27 | 936.5 - 939.5 | 1.56 | Amp | G7W |
| Class II Permissive Change to add LTE operation. DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| ADRF KOREA, Inc. |
| 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, |
| Kyunggi-Do,, South Korea |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 928.0 - 929.0 | 2.193 | Amp | F1D | |
| 101 | 928.0 - 929.0 | 2.056 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 1.919 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 2.009 | Amp | F1D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
EAS Grant - Application SIrG7wDZ+AxAjsFW5Wb5kA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ADRF KOREA, Inc. 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, P.O. Box , Kyunggi-Do,, South Korea |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 928.0 - 929.0 | 2.193 | Amp | F1D | |
| 101 | 928.0 - 929.0 | 2.056 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 1.919 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 2.009 | Amp | F1D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| ADRF KOREA, Inc. |
| 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, |
| Kyunggi-Do,, South Korea |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 90 Class A Industrial Booster (non-SMR) |
| Notes: | DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 929.0 - 930.0 | 2.109 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 1.892 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 2.109 | Amp | F2D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
EAS Grant - Application cQ9tUQKhciBMDRgzM36ofw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ADRF KOREA, Inc. 5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, P.O. Box , Kyunggi-Do,, South Korea |
Date of Grant: 09/10/2020 Application Dated: 09/10/2020 |
| Attention: Hyun-Kyung Song , Management Support Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | N52-ADXV-R-339P |
| Name of Grantee: | ADRF KOREA, Inc. |
| Equipment Class: | Part 90 Class A Industrial Booster (non-SMR) |
| Notes: | DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 929.0 - 930.0 | 2.109 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 1.892 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 2.109 | Amp | F2D |
| DAS. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 3 dBi with minimum separation distance 30 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
| Mail To: |