FCC ID N5WNP2XSBSM01

Single-Band Single Mode PCS CDMA Phone

by NeoPoint Inc.

Grantee Code: N5W   Product Code: NP2XSBSM01
Latest application date: 2000-09-18

FCC ID Device Details

FCC IDN5WNP2XSBSM01
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeN5W
Product CodeNP2XSBSM01
Applicant BusinessNeoPoint Inc. 🇺🇸
Related Domains neopoint.com pctestlab.com
Equipment ClassSingle-Band Single Mode PCS CDMA Phone

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1851.25-1908.75 MHzOriginal Equipment2000-09-18

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2000-09-18PDF 4.5 MB
Internal PhotographsInternal Photos2000-09-18PDF 2 MB
External PhotographsExternal Photos2000-09-18PDF 747 KB
Sample Label and locationID Label/Location Info2000-09-18PDF 32.3 KB
Block DiagramBlock Diagram2000-09-18PDF 66.5 KB
Operational Description and Antenna SpecificationsOperational Description2000-09-18PDF 1.2 MB
SAR Test Setup PhotosRF Exposure Info2000-09-18PDF 1.2 MB
Test Setup PhotosTest Setup Photos2000-09-18PDF 831.6 KB
SAR Test ReportRF Exposure Info2000-09-18PDF 551.3 KB
Test PlotsTest Report2000-09-18PDF 1.1 MB
Test ReportTest Report2000-09-18PDF 366.5 KB
Authorization Statement Confidentiality RequestAttestation Statements2000-09-18PDF 82 KB
Cover LetterCover Letter(s)2000-09-18PDF 81.3 KB
Dipole ValidationRF Exposure Info2000-09-18PDF 132.6 KB
Probe CalibrationRF Exposure Info2000-09-18PDF 145.1 KB
RF Exposure Warning StatementRF Exposure Info2000-09-18PDF 23.3 KB
SAR Test DataRF Exposure Info2000-09-18PDF 760.6 KB
Schematics Metadata onlySchematicsPDF 153.8 KB
Parts List and Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 161.4 KB

Application Information

Application ID8XbclAjZJWdILkySAGrVVg==
Final Action Date2000-09-18
Application PurposeOriginal Equipment
Applicant FRN9999999999
ModelNP2XSBSM01
Frequency Range1851.25-1908.75 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionSingle-Band Single Mode PCS CDMA Phone
Responsible PartyKye Cheung, Director of Product Marketing & Development, kcheung@neopoint.com , 858-678-3054
AgentRandy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Non-Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is EIRP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The Highest reported SAR values are - Head: 1.45 W/kg; Body-worn: 1.16 W/kg

Applications

Application IDDatePurpose
8XbclAjZJWdILkySAGrVVg==2000-09-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1851.25-1908.75 MHz0.45700002.5000000000ppm1M25F9W24

Grants

TCB Grant - Application 8XbclAjZJWdILkySAGrVVg==

This application does not exist.

EAS Grant - Application 8XbclAjZJWdILkySAGrVVg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

NeoPoint Inc.
4225 Executive Square Suite 600
La Jolla, CA 92037
United States
  Date of Grant: 09/18/2000

Application Dated: 08/15/2000
 
Attention: Kye Cheung , Director of Product Marketing & Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N5WNP2XSBSM01
Name of Grantee:  NeoPoint Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Single-Band Single Mode PCS CDMA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24 1851.25  -  1908.75 0.457 2.5  PM 1M25F9W

Output is EIRP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The Highest reported SAR values are - Head: 1.45 W/kg; Body-worn: 1.16 W/kg



Mail To:
Randy Ortanez, President
PCTEST Engineering Laboratory, Inc.
6660-B Dobbin Road