FCC ID N9MSC1002

SCANTER 1002 GSR

by Terma A/S

Grantee Code: N9M   Product Code: SC1002
Latest application date: 2019-04-22

FCC ID Device Details

FCC IDN9MSC1002
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeN9M
Product CodeSC1002
Applicant BusinessTerma A/S 🇩🇰
Related Domains termana.com
Equipment ClassSCANTER 1002 GSR
Test FirmWashington Laboratories, Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
17136-17279 MHzOriginal Equipment2019-04-22

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2019-10-19PDF 1.1 MB
Internal PhotosInternal Photos2019-10-19PDF 5 MB
External PhotosExternal Photos2019-10-19PDF 244.5 KB
ID LabelID Label/Location Info2019-04-22PDF 221.2 KB
ID Label LocationID Label/Location Info2019-04-22PDF 243.6 KB
Test Set- up PhotosTest Setup Photos2019-10-19PDF 2.5 MB
Test ReportTest Report2019-04-22PDF 1.1 MB
Authorization LetterCover Letter(s)2019-04-22PDF 251.8 KB
Confidentiality RequestCover Letter(s)2019-04-22PDF 164.8 KB
MPE ReportRF Exposure Info2019-04-22PDF 268.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 1.2 MB
Schematics Metadata onlySchematicsPDF 3.2 MB
KDB Inquiry and Response Metadata onlyOperational DescriptionPDF 176.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 1 MB
BOM Metadata onlyParts List/Tune Up InfoPDF 282.2 KB
Tune- Up Procedure Metadata onlyParts List/Tune Up InfoPDF 3.1 MB

Application Information

Application IDW7JwMnEOOKpP4eb9nidQ/Q==
Final Action Date2019-04-22
Application PurposeOriginal Equipment
Applicant FRN0026710418
ModelSC1002
Frequency Range17136-17279 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionSCANTER 1002 GSR
Responsible PartyDorothy S Hersey, Counsel and Corporate Secretary, dottie.hersey@termana.com , 517-228-5179
AgentSteve Steve Steve, Washington Laboratories, Ltd., stevek@wll.com , 301-216-1500
Technical ContactKarsten Biehl, TERMA Elektronik AS, kabi@terma.com , 45 8743 6000
Non-Technical ContactDorothy Hersey, TERMA North America, dottie.hersey@termana.com , 703 412 9410
Test FirmSteve Koster, Washington Laboratories, Ltd., stevek@wll.com , 301-216-1500
TCB Emailhotline@acbcert.com
TCB ScopeB4: Microwave, Millimeter Wave Band and Citizens Broadband Radio Services equipment in 47 CFR Parts 25, 30, 74, 90, 95, 96, 97, 101 (all above 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date10/19/2019
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power listed is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing - this device complies with KDB 447498 and is approved for mobile/fixed operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
W7JwMnEOOKpP4eb9nidQ/Q==2019-04-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
17136-17279 MHz5.333100ppm18M4V7N90F
17140-17260 MHz6.622100ppm38M7V7N90F

Grants

TCB Grant - Application W7JwMnEOOKpP4eb9nidQ/Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 04/22/2019

Application Dated: 04/22/2019
Terma A/S
Hovmarken 4
Lystrup 8520, DK-8520
Denmark
 
Attention: Dorothy Hersey , Counsel and Corporate Secretary

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N9MSC1002
Name of Grantee:  Terma A/S
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: SCANTER 1002 GSR
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90F 17140.0  -  17260.0 6.622 100.0  PM 38M7V7N
90F 17136.0  -  17279.0 5.333 100.0  PM 18M4V7N

Output power listed is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing - this device complies with KDB 447498 and is approved for mobile/fixed operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance.

EAS Grant - Application W7JwMnEOOKpP4eb9nidQ/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Terma A/S
Hovmarken 4
Lystrup 8520, DK-8520
Denmark
  Date of Grant: 04/22/2019

Application Dated: 04/22/2019
 
Attention: Dorothy Hersey , Counsel and Corporate Secretary

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N9MSC1002
Name of Grantee:  Terma A/S
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: SCANTER 1002 GSR
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90F 17140.0  -  17260.0 6.622 100.0  PM 38M7V7N
90F 17136.0  -  17279.0 5.333 100.0  PM 18M4V7N

Output power listed is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing - this device complies with KDB 447498 and is approved for mobile/fixed operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance.



Mail To: