Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2021-04-16
5180-5240 MHzOriginal Equipment2021-04-16
2402-2480 MHzOriginal Equipment2021-04-16

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2021-04-16PDF 1.8 MB
Int photoInternal Photos2021-04-16PDF 941.6 KB
Ext photoExternal Photos2021-04-16PDF 1.2 MB
LabelID Label/Location Info2021-04-16PDF 292.1 KB
labelID Label/Location Info2021-04-16PDF 292.1 KB
Test photoTest Setup Photos2021-04-16PDF 415.5 KB
Test photoTest Setup Photos2021-04-16PDF 373 KB
test photoTest Setup Photos2021-04-16PDF 415.5 KB
Test reportTest Report2021-04-16PDF 1 MB
Test reportTest Report2021-04-16PDF 5 MB
Test reportTest Report2021-04-16PDF 2.8 MB
Test reportTest Report2021-04-16PDF 4.9 MB
Agent_AuthorizationCover Letter(s)2021-04-16PDF 39.9 KB
FCC Long Term Confidentiality RequestCover Letter(s)2021-04-16PDF 102.6 KB
FCC Software Configuration Control DeclarationCover Letter(s)2021-04-16PDF 90.9 KB
FCC_Short_Long_Term_Confidentiality_RequestCover Letter(s)2021-04-16PDF 102.6 KB
RF ExposureRF Exposure Info2021-04-16PDF 289.1 KB
RF Exposure EvaluationRF Exposure Info2021-04-16PDF 289.1 KB
Block Metadata onlyBlock DiagramPDF 395.8 KB
SCH Metadata onlySchematicsPDF 1.6 MB
OP Metadata onlyOperational DescriptionPDF 106.7 KB
NII Software Security Info Metadata onlySDR Software/Security InfPDF 144.1 KB

Application Information

Application IDx0Bfl1mPwGNAw64lW/HQew==
Final Action Date2021-04-16
Application PurposeOriginal Equipment
Applicant FRN0015296189
ModelM360-M500
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionAI Safety System
Responsible PartyMirror Hu, Engineer, mirrorhu@via.com.tw , 886-2-2218-5452
Technical ContactVIA Technologies Inc., mirrorhu@via.com.tw
Test FirmZhang Shuangwen, CCIC Southern Testing Co., Ltd, zhangsw@ccic-set.com , 86-0755-86131239
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
x0Bfl1mPwGNAw64lW/HQew==2021-04-16Original Equipment
mqlCurRpBdusnZt1hBrg1A==2021-04-16Original Equipment
ZJ+pkWRu093QK1brpI8jpg==2021-04-16Original Equipment
AMmkOIuqQbtw1dwWG2lR8Q==2021-04-16Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
2402-2480 MHz0.003000015CCC
2402-2480 MHz0.002515CCC
2412-2462 MHz0.04815CCC
5180-5240 MHz0.01915E38, CC
5745-5825 MHz0.01915E38, CC

Grants

TCB Grant - Application ZJ+pkWRu093QK1brpI8jpg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/16/2021

Application Dated: 04/16/2021
VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AI Safety System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.019  
38 CC 15E 5745.0  -  5825.0 0.019  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ZJ+pkWRu093QK1brpI8jpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
  Date of Grant: 04/16/2021

Application Dated: 04/16/2021
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AI Safety System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.019  
38 CC 15E 5745.0  -  5825.0 0.019  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application x0Bfl1mPwGNAw64lW/HQew==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/16/2021

Application Dated: 04/16/2021
VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Digital Transmission System
Notes: AI Safety System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0025  
CC 15C 2412.0  -  2462.0 0.048  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application x0Bfl1mPwGNAw64lW/HQew==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
  Date of Grant: 04/16/2021

Application Dated: 04/16/2021
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Digital Transmission System
Notes: AI Safety System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0025  
CC 15C 2412.0  -  2462.0 0.048  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application mqlCurRpBdusnZt1hBrg1A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/16/2021

Application Dated: 04/16/2021
VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Part 15 Class B Digital Device
Notes: AI Safety System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application mqlCurRpBdusnZt1hBrg1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
  Date of Grant: 04/16/2021

Application Dated: 04/16/2021
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Part 15 Class B Digital Device
Notes: AI Safety System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application AMmkOIuqQbtw1dwWG2lR8Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/16/2021

Application Dated: 04/16/2021
VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AI Safety System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application AMmkOIuqQbtw1dwWG2lR8Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VIA Technologies, Inc.
8F, No.535, Zhongzheng Rd.,
Xindian Dist, New Taipei,
Taiwan
  Date of Grant: 04/16/2021

Application Dated: 04/16/2021
 
Attention: Mirror Hu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCI-M360-M500
Name of Grantee:  VIA Technologies, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AI Safety System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.