Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2015-01-29
5180-5240 MHzOriginal Equipment2015-01-29

Exhibits

DocumentTypeAvailableFile
Installation ManualUsers Manual2015-01-29PDF 462.7 KB
User ManualUsers Manual2015-01-29PDF 1.3 MB
Internal PhotosInternal Photos2015-01-29PDF 1.3 MB
Internal PhtoInternal Photos2015-01-29PDF 1.3 MB
External PhotosExternal Photos2015-01-29PDF 247.1 KB
ID Label LocationID Label/Location Info2015-01-29PDF 210.1 KB
Test Setup PhotosTest Setup Photos2015-01-29PDF 424.3 KB
Test ReportTest Report2015-01-29PDF 5.2 MB
Test ReportTest Report2015-01-29PDF 1.1 MB
Test ReportTest Report2015-01-29PDF 5.4 MB
Attestation LetterCover Letter(s)2015-01-29PDF 37.9 KB
Authorization LetterCover Letter(s)2015-01-29PDF 83.5 KB
Confidentiality LetterCover Letter(s)2015-01-29PDF 43.1 KB
Declaration LetterCover Letter(s)2015-01-29PDF 208.1 KB
RF ExposureRF Exposure Info2015-01-29PDF 72.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 22.3 KB
Schematics Metadata onlySchematicsPDF 461.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 55.7 KB

Application Information

Application IDXso6h6g2JBMWltydRtpjcw==
Final Action Date2015-01-29
Application PurposeOriginal Equipment
Applicant FRN0005941505
ModelA600
Equipment ClassJBP - Part 15 Class B Computing Device Peripheral
Device DescriptionAltum AC600
Responsible PartyChristopher A Gustaf, VP, Engineering, chris@trangosys.com , 858-391-0010
AgentWu Wu Wu, MRT Technology, 0086-512-66308358
Test FirmWu Jian, MRT Technology (Suzhou) Co., Ltd, robinwu@mrt-cert.com , 86-512-66308358
TCB Emailkknoerig@emcc.de
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
Xso6h6g2JBMWltydRtpjcw==2015-01-29Original Equipment
K8gcGKM8dmk5XkOjNK+c1g==2015-01-29Original Equipment
DKaEE8ZoPP1r9on9DmKdkg==2015-01-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.29615CCC, MO
2422-2452 MHz0.2815CCC, MO
5180-5240 MHz0.03215E38, CC, MO
5745-5825 MHz0.81815E38, CC, MO

Grants

TCB Grant - Application Xso6h6g2JBMWltydRtpjcw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCons DR RASEK GmbH & Co. KG
Stoernhofer Berg 15
Unterleinleiter, 91364
Germany
Date of Grant: 01/29/2015

Application Dated: 01/29/2015
Trango Systems Inc
14118 Stowe Drive
Suite B
Poway, CA 92064
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Altum AC600
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 


EAS Grant - Application Xso6h6g2JBMWltydRtpjcw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Trango Systems Inc
14118 Stowe Drive Suite B
Poway, CA 92064
United States
  Date of Grant: 01/29/2015

Application Dated: 01/29/2015
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Altum AC600
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 



TCB Grant - Application K8gcGKM8dmk5XkOjNK+c1g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCons DR RASEK GmbH & Co. KG
Stoernhofer Berg 15
Unterleinleiter, 91364
Germany
Date of Grant: 01/29/2015

Application Dated: 01/29/2015
Trango Systems Inc
14118 Stowe Drive
Suite B
Poway, CA 92064
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Digital Transmission System
Notes: Altum AC600
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.296  
CC MO 15C 2422.0  -  2452.0 0.28  

Output power listed is peak conducted. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 144 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application K8gcGKM8dmk5XkOjNK+c1g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Trango Systems Inc
14118 Stowe Drive Suite B
Poway, CA 92064
United States
  Date of Grant: 01/29/2015

Application Dated: 01/29/2015
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Digital Transmission System
Notes: Altum AC600
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.296  
CC MO 15C 2422.0  -  2452.0 0.28  

Output power listed is peak conducted. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 144 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application DKaEE8ZoPP1r9on9DmKdkg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCons DR RASEK GmbH & Co. KG
Stoernhofer Berg 15
Unterleinleiter, 91364
Germany
Date of Grant: 01/29/2015

Application Dated: 01/29/2015
Trango Systems Inc
14118 Stowe Drive
Suite B
Poway, CA 92064
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Altum AC600
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.032  
38 CC MO 15E 5745.0  -  5825.0 0.818  

Output power listed is peak conducted. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 144 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. device has a 20 MHz, 40 MHz and 80 MHz bandwidth mode.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application DKaEE8ZoPP1r9on9DmKdkg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Trango Systems Inc
14118 Stowe Drive Suite B
Poway, CA 92064
United States
  Date of Grant: 01/29/2015

Application Dated: 01/29/2015
 
Attention: Christopher Gustaf , VP, Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NCY-A600
Name of Grantee:  Trango Systems Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Altum AC600
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.032  
38 CC MO 15E 5745.0  -  5825.0 0.818  

Output power listed is peak conducted. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 144 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. device has a 20 MHz, 40 MHz and 80 MHz bandwidth mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: