FCC ID NDD9520041907

Indoor Air Quality Detector

by Edimax Technology Co Ltd

Grantee Code: NDD   Product Code: 9520041907
Latest application date: 2019-11-10

FCC ID Device Details

FCC IDNDD9520041907
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNDD
Product Code9520041907
Applicant BusinessEdimax Technology Co Ltd 🇹🇼
Related Domains edimax.com.tw
Equipment ClassIndoor Air Quality Detector
Test FirmA Test Lab Techno Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-11-10

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2019-11-10PDF 1.7 MB
Internal photosInternal Photos2019-11-10PDF 4.8 MB
External photosExternal Photos2019-11-10PDF 1,019 KB
Label locationID Label/Location Info2019-11-10PDF 396 KB
Label-AI-2003WID Label/Location Info2019-11-10PDF 369 KB
Label-AI-2004WID Label/Location Info2019-11-10PDF 367.1 KB
RF Test set-up Photo-WIFITest Setup Photos2019-11-10PDF 900.7 KB
RF Test set-up photo-BLETest Setup Photos2019-11-10PDF 886.3 KB
RF Test Report-BLETest Report2019-11-10PDF 2.7 MB
RF Test Report-WIFITest Report2019-11-10PDF 3.1 MB
Authorization LetterCover Letter(s)2019-11-10PDF 273.8 KB
Family Model LetterCover Letter(s)2019-11-10PDF 129.9 KB
LTC LetterCover Letter(s)2019-11-10PDF 2.8 MB
WIFI Channel 12&13 Description letterCover Letter(s)2019-11-10PDF 160.1 KB
RF Exposure reportRF Exposure Info2019-11-10PDF 625.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 62.5 KB
Schematics Metadata onlySchematicsPDF 211.9 KB
Operational description Metadata onlyOperational DescriptionPDF 123.7 KB

Application Information

Application IDOgLiJg3tkoIo0NLmfPmphA==
Final Action Date2019-11-10
Application PurposeOriginal Equipment
Applicant FRN0008842908
Model9520041907
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionIndoor Air Quality Detector
Responsible PartyTracy Cheng, senior Specialist, tracy@edimax.com.tw , +886-2-7739-6639
Test FirmFly LU, A Test Lab Techno Corp., Fly@atl-lab.com.tw , 88632710188
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

Applications

Application IDDatePurpose
OgLiJg3tkoIo0NLmfPmphA==2019-11-10Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001815C
2412-2462 MHz0.4215C

Grants

TCB Grant - Application OgLiJg3tkoIo0NLmfPmphA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 11/10/2019

Application Dated: 11/08/2019
Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9520041907
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: Indoor Air Quality Detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0018  
15C 2412.0  -  2462.0 0.42  

Power listed is the maximum conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

EAS Grant - Application OgLiJg3tkoIo0NLmfPmphA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
  Date of Grant: 11/10/2019

Application Dated: 11/08/2019
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9520041907
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: Indoor Air Quality Detector
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0018  
15C 2412.0  -  2462.0 0.42  

Power listed is the maximum conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.



Mail To: