FCC ID NDD9564081112

300N WLAN Broadband Router

by Edimax Technology Co Ltd

Grantee Code: NDD   Product Code: 9564081112
Latest application date: 2012-04-16

FCC ID Device Details

FCC IDNDD9564081112
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNDD
Product Code9564081112
Applicant BusinessEdimax Technology Co Ltd 🇹🇼
Related Domains edimax.com.tw
Equipment Class300N WLAN Broadband Router
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2012-04-16

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2012-04-16PDF 2 MB
Internal PhotosInternal Photos2012-04-16PDF 2.9 MB
External PhotosExternal Photos2012-04-16PDF 1.2 MB
LabelID Label/Location Info2012-04-16PDF 324.5 KB
Test Setup PhotosTest Setup Photos2012-04-16PDF 3.4 MB
Test ReportTest Report2012-04-16PDF 4.4 MB
Test Report ColocationTest Report2012-04-16PDF 2.5 MB
Test Report IITest Report2012-04-16PDF 4.4 MB
Ad hoc letterCover Letter(s)2012-04-16PDF 218.5 KB
DOC letterCover Letter(s)2012-04-16PDF 221.1 KB
LTC requestCover Letter(s)2012-04-16PDF 242.8 KB
PoACover Letter(s)2012-04-16PDF 261.5 KB
MPERF Exposure Info2012-04-16PDF 20.7 KB

Application Information

Application IDg9PcgPDydx+CszTOriwW7w==
Final Action Date2012-04-16
Application PurposeOriginal Equipment
Applicant FRN0008842908
Model9564081112
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device Description300N WLAN Broadband Router
Responsible PartyTracy Cheng, senior Specialist, tracy@edimax.com.tw , +886-2-7739-6639
AgentWayne Wayne Wayne, Sporton Int., wayne@sporton.com.tw , 886-33273456
Test FirmAlex Chen, Sporton International Inc., alex@sporton.com.tw , 886-3-327-3456
TCB EmailBrandhorst.dirk@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum combined conducted peak output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. When operating in 802.11n, 40 MHz mode, the operating frequency segment is limited to 2422 to 2452 MHz

Applications

Application IDDatePurpose
g9PcgPDydx+CszTOriwW7w==2012-04-16Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.16415CMO
2422-2452 MHz0.10715CMO

Grants

TCB Grant - Application g9PcgPDydx+CszTOriwW7w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 04/16/2012

Application Dated: 04/16/2012
Edimax Technology Co Ltd
No.3 , Wu-Chuan 3rd Road ,
Wu-Ku Industrial Park .
Taipei Hsien,
Taiwan
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9564081112
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: 300N WLAN Broadband Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.164  
MO 15C 2422.0  -  2452.0 0.107  

Output Power listed is the maximum combined conducted peak output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. When operating in 802.11n, 40 MHz mode, the operating frequency segment is limited to 2422 to 2452 MHz

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application g9PcgPDydx+CszTOriwW7w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Edimax Technology Co Ltd
No.3 , Wu-Chuan 3rd Road , Wu-Ku Industrial Park .
Taipei Hsien,
Taiwan
  Date of Grant: 04/16/2012

Application Dated: 04/16/2012
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9564081112
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: 300N WLAN Broadband Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.164  
MO 15C 2422.0  -  2452.0 0.107  

Output Power listed is the maximum combined conducted peak output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. When operating in 802.11n, 40 MHz mode, the operating frequency segment is limited to 2422 to 2452 MHz


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: