FCC ID NDD9574761413

AC 100 Dual Band Concurrent Ceiling-Mount Access Point

by Edimax Technology Co Ltd

Grantee Code: NDD   Product Code: 9574761413
Latest application date: 2016-03-14

Device Images

FCC ID Device Details

FCC IDNDD9574761413
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNDD
Product Code9574761413
Applicant BusinessEdimax Technology Co Ltd 🇹🇼
Related Domains edimax.com.tw
Equipment ClassAC 100 Dual Band Concurrent Ceiling-Mount Access Point
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2016-03-14
2412-2462 MHzOriginal Equipment2015-01-20
5180-5240 MHzOriginal Equipment2015-01-20

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2016-03-14PDF 3.4 MB
user manualUsers Manual2015-01-20PDF 4.5 MB
int photosInternal Photos2015-01-20PDF 1.3 MB
ext photosExternal Photos2015-01-20PDF 370.8 KB
labelID Label/Location Info2015-01-20PDF 151.5 KB
Test Setup photosTest Setup Photos2016-03-14PDF 262.6 KB
Test Setup photosTest Setup Photos2015-01-20PDF 269.8 KB
Test Setup photosTest Setup Photos2015-01-20PDF 279.2 KB
test setup photosTest Setup Photos2015-01-20PDF 279.2 KB
DFS ReportTest Report2016-03-14PDF 2 MB
Test reportTest Report2016-03-14PDF 3.3 MB
Test report colocationTest Report2015-01-20PDF 294.6 KB
colocationTest Report2015-01-20PDF 294.6 KB
test reportTest Report2015-01-20PDF 5.5 MB
test reportTest Report2015-01-20PDF 2.7 MB
C2PC Change letterCover Letter(s)2016-03-14PDF 108.2 KB
LTC requestCover Letter(s)2016-03-14PDF 149.8 KB
PoACover Letter(s)2016-03-14PDF 176.8 KB
ad hoc mode letterCover Letter(s)2016-03-14PDF 43.3 KB
LTC requestCover Letter(s)2015-01-20PDF 49.4 KB
PoACover Letter(s)2015-01-20PDF 62 KB
ad hoc mode letterCover Letter(s)2015-01-20PDF 37.8 KB
MPERF Exposure Info2016-03-14PDF 56.4 KB
MPERF Exposure Info2015-01-20PDF 68.6 KB
block diagram Metadata onlyBlock DiagramPDF 1.2 MB
schematics Metadata onlySchematicsPDF 804.1 KB
Software Security Metadata onlyOperational DescriptionPDF 45.7 KB
Software Security Metadata onlyOperational DescriptionPDF 51.5 KB
operational description Metadata onlyOperational DescriptionPDF 19.7 KB

Application Information

Application IDgLs8aKsLmGkZR6XgiB542g==
Final Action Date2016-03-14
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0008842908
Model9574761413
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionAC 100 Dual Band Concurrent Ceiling-Mount Access Point
Responsible PartyTracy Cheng, senior Specialist, tracy@edimax.com.tw , +886-2-7739-6639
AgentKevin Kevin Kevin, Sporton Int Inc, KevinLiang@sporton.com.tw , 88633273456
Test FirmAlex Chen, Sporton International Inc., alex@sporton.com.tw , 886-3-327-3456
TCB EmailKhalek.Yassine@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsClass II permissive change adds DFS Band 2 and 3. Output Power listed is the maximum combined conducted output power as indicated in the filing. This device and its antennas must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. Operation of this device is restricted to indoor use only. This device has 20,40 and 80 MHz BW modes. Operation of this device is restricted to indoor use only.

Applications

Application IDDatePurpose
gLs8aKsLmGkZR6XgiB542g==2016-03-14Class II permissive change or modification of presently authorized equipment
JQCmet3AlCJo6n2qiz9NcQ==2015-01-20Original Equipment
2edVh8lVoJB9XaaG58Tycg==2015-01-20Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.998000015CCC, MO
5180-5240 MHz0.14815E38, CC, MO
5260-5320 MHz0.16515E38, CC, MO, ND
5500-5700 MHz0.23315E38, CC, MO, ND
5745-5825 MHz0.44215E38, CC, MO

Grants

TCB Grant - Application JQCmet3AlCJo6n2qiz9NcQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 01/20/2015

Application Dated: 01/20/2015
Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: AC1200 Dual Band Concurrent Ceiling-Mount Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.998  

Output Power listed is the maximum combined conducted peak output power as indicated in the filing. This device and its antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device has 20 and 40 MHz BW modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application JQCmet3AlCJo6n2qiz9NcQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
  Date of Grant: 01/20/2015

Application Dated: 01/20/2015
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: AC1200 Dual Band Concurrent Ceiling-Mount Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.998  

Output Power listed is the maximum combined conducted peak output power as indicated in the filing. This device and its antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. This device has 20 and 40 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application gLs8aKsLmGkZR6XgiB542g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 03/14/2016

Application Dated: 11/18/2015
Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC 100 Dual Band Concurrent Ceiling-Mount Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.148  
38 CC MO 15E 5745.0  -  5825.0 0.442  
38 CC MO ND 15E 5260.0  -  5320.0 0.165  
38 CC MO ND 15E 5500.0  -  5700.0 0.233  

Class II permissive change adds DFS Band 2 and 3.

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device and its antennas must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. Operation of this device is restricted to indoor use only. This device has 20,40 and 80 MHz BW modes. Operation of this device is restricted to indoor use only.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application gLs8aKsLmGkZR6XgiB542g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
  Date of Grant: 03/14/2016

Application Dated: 11/18/2015
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC 100 Dual Band Concurrent Ceiling-Mount Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.148  
38 CC MO 15E 5745.0  -  5825.0 0.442  
38 CC MO ND 15E 5260.0  -  5320.0 0.165  
38 CC MO ND 15E 5500.0  -  5700.0 0.233  

Class II permissive change adds DFS Band 2 and 3.

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device and its antennas must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. Operation of this device is restricted to indoor use only. This device has 20,40 and 80 MHz BW modes. Operation of this device is restricted to indoor use only.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application 2edVh8lVoJB9XaaG58Tycg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 01/20/2015

Application Dated: 01/20/2015
Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Dual Band Concurrent Ceiling-Mount Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.148  
38 CC MO 15E 5745.0  -  5825.0 0.442  

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device and its antennas must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. Operation of this device is restricted to indoor use only. This device has 20,40 and 80 MHz BW modes. Operation of this device is restricted to indoor use only.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 2edVh8lVoJB9XaaG58Tycg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Edimax Technology Co Ltd
No.278 , Xinhu 1st Rd. , Neihu Dist. ,
Taipei City,
Taiwan
  Date of Grant: 01/20/2015

Application Dated: 01/20/2015
 
Attention: Tracy Cheng , senior Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NDD9574761413
Name of Grantee:  Edimax Technology Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Dual Band Concurrent Ceiling-Mount Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.148  
38 CC MO 15E 5745.0  -  5825.0 0.442  

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device and its antennas must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 2T2R Spatial Multiplexing MIMO configuration as described in this filing. Operation of this device is restricted to indoor use only. This device has 20,40 and 80 MHz BW modes. Operation of this device is restricted to indoor use only.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: