FCC ID NM8RHOD300

PDA Phone

by HTC Corporation

Grantee Code: NM8   Product Code: RHOD300
Latest application date: 2009-06-04

FCC ID Device Details

FCC IDNM8RHOD300
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNM8
Product CodeRHOD300
Applicant BusinessHTC Corporation 🇹🇼
Related Domains htc.com
Equipment ClassPDA Phone
Test FirmSGS TAIWAN LTD.

Hearing Aid Compatibility

Handset MakerHTC
Model NameRHOD300
Air Interface TechnologiesGSM, GSM
Operating Frequency Bands850, 1900
M-RatingM3
M-Rating Certification Date06/04/09
M-Rating ANSI Version2007
T-RatingT3
T-Rating Certification Date06/04/09
T-Rating ANSI Version2007
Wi-Fi InterfaceY

Source: FCC archived Device Manufacturer Summary Report (2010).

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2009-06-04
824.2-848.8 MHzOriginal Equipment2009-06-04
2412-2462 MHzOriginal Equipment2009-06-04

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2009-11-30PDF 3.2 MB
Internal PhotosInternal Photos2009-11-30PDF 227 KB
External PhotosExternal Photos2009-11-30PDF 271.2 KB
ID Label InfoID Label/Location Info2009-06-04PDF 97.5 KB
HAC Test Setup PhotosTest Setup Photos2009-11-30PDF 219.1 KB
SAR Test Setup PhotosTest Setup Photos2009-11-30PDF 515.9 KB
Test Setup Photo IITest Setup Photos2009-11-30PDF 135.5 KB
Test Setup Photos ITest Setup Photos2009-11-30PDF 130.1 KB
Test Setup Photos IITest Setup Photos2009-11-30PDF 135.5 KB
Test Setup Photos IIITest Setup Photos2009-11-30PDF 269.6 KB
HAC Test ReportTest Report2009-06-04PDF 2.7 MB
SAR Test Report IRF Exposure Info2009-06-04PDF 1.4 MB
SAR Test Report IIRF Exposure Info2009-06-04PDF 2.4 MB
Test ReportTest Report2009-06-04PDF 1.8 MB
Test ReportTest Report2009-06-04PDF 993.1 KB
Test Report IITest Report2009-06-04PDF 1.9 MB
Test Report IIITest Report2009-06-04PDF 2 MB
Test Report IVTest Report2009-06-04PDF 2.6 MB
Test Report VTest Report2009-06-04PDF 2.1 MB
Test Report VITest Report2009-06-04PDF 2.5 MB
Test Report VIITest Report2009-06-04PDF 1.1 MB
Test Report VIIITest Report2009-06-04PDF 1.5 MB
Authorization LetterCover Letter(s)2009-06-04PDF 27.8 KB
Confidentiality LetterCover Letter(s)2009-06-04PDF 514.7 KB
Confidentiality RequestCover Letter(s)2009-06-04PDF 514.7 KB
Declaration LetterCover Letter(s)2009-06-04PDF 33.4 KB

Application Information

Application IDkFXZmTZMPnfCogDIuBnMDw==
Final Action Date2009-06-04
Application PurposeOriginal Equipment
Applicant FRN0018127647
ModelRHOD300
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionPDA Phone
Responsible PartyHedy Hsieh, Hedy_Hsieh@htc.com , 886289124138
AgentVincent Vincent Vincent, SGS Taiwan Ltd., +886-222-9933279
Test FirmNELSON BAI, SGS TAIWAN LTD., nelson.bai@sgs.com , 886-2-22993279
TCB Emailkknoerig@emcc.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/30/2009
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

Applications

Application IDDatePurpose
kFXZmTZMPnfCogDIuBnMDw==2009-06-04Original Equipment
fZiXUrbhWLmAp06wtV4CQQ==2009-06-04Original Equipment
BX50Jej+ThI/5Pb7qw7WRg==2009-06-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.0142.5ppm245KGXW22HHC
824.2-848.8 MHz0.2232.5ppm242KG7W22HHC
826.4-846.6 MHz0.0282.5ppm4M17F9W22HHC
1850.2-1909.8 MHz0.4292.5ppm248KGXW24EHC
1850.2-1909.8 MHz0.1162.5ppm246KG7W24EHC
1852.4-1907.6 MHz0.0872.5ppm4M18F9W24EHC
2402-2480 MHz0.001270015CCC
2412-2462 MHz0.071000015CCC

Grants

TCB Grant - Application kFXZmTZMPnfCogDIuBnMDw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15
91364 Unterleinleiter,
Germany
Date of Grant: 06/04/2009

Application Dated: 06/04/2009
HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PDA Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00127  

Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application kFXZmTZMPnfCogDIuBnMDw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
  Date of Grant: 06/04/2009

Application Dated: 06/04/2009
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PDA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00127  

Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application fZiXUrbhWLmAp06wtV4CQQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15
91364 Unterleinleiter,
Germany
Date of Grant: 06/04/2009

Application Dated: 06/04/2009
HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: PDA Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1850.2  -  1909.8 0.429 2.5  PM 248KGXW
HC 24E 1850.2  -  1909.8 0.116 2.5  PM 246KG7W
HC 24E 1852.4  -  1907.6 0.087 2.5  PM 4M18F9W
HC 22H 824.2  -  848.8 1.014 2.5  PM 245KGXW
HC 22H 824.2  -  848.8 0.223 2.5  PM 242KG7W
HC 22H 826.4  -  846.6 0.028 2.5  PM 4M17F9W

Output power is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. Collocated transmitter operating configurations have been evaluated as described in this filing; other collocation configurations require separate evaluation. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22 Head: 0.876 W/kg, Body-worn: 1.26 W/kg; Part 24 Head: 1.16 W/kg, Body-worn: 0.581 W/kg; Part 15 Body-worn: 0.031 W/kg. HAC Rating: M3T3-2007

HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

EAS Grant - Application fZiXUrbhWLmAp06wtV4CQQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
  Date of Grant: 06/04/2009

Application Dated: 06/04/2009
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: PDA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1850.2  -  1909.8 0.429 2.5  PM 248KGXW
HC 24E 1850.2  -  1909.8 0.116 2.5  PM 246KG7W
HC 24E 1852.4  -  1907.6 0.087 2.5  PM 4M18F9W
HC 22H 824.2  -  848.8 1.014 2.5  PM 245KGXW
HC 22H 824.2  -  848.8 0.223 2.5  PM 242KG7W
HC 22H 826.4  -  846.6 0.028 2.5  PM 4M17F9W

Output power is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. Collocated transmitter operating configurations have been evaluated as described in this filing; other collocation configurations require separate evaluation. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22 Head: 0.876 W/kg, Body-worn: 1.26 W/kg; Part 24 Head: 1.16 W/kg, Body-worn: 0.581 W/kg; Part 15 Body-worn: 0.031 W/kg. HAC Rating: M3T3-2007


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

TCB Grant - Application BX50Jej+ThI/5Pb7qw7WRg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15
91364 Unterleinleiter,
Germany
Date of Grant: 06/04/2009

Application Dated: 06/04/2009
HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: Digital Transmission System
Notes: PDA Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.071  

Collocated transmitter operating configurations have been evaluated as described in this filing; other collocation configurations require separate evaluation. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22 Head: 0.876 W/kg, Body-worn: 1.26 W/kg; Part 24 Head: 1.16 W/kg, Body-worn: 0.581 W/kg; Part 15 Body-worn: 0.031 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application BX50Jej+ThI/5Pb7qw7WRg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HTC Corporation
1F, 6-3 Baoqiang Road, Xindian District,
New Taipei City, 231
Taiwan
  Date of Grant: 06/04/2009

Application Dated: 06/04/2009
 
Attention: Hedy Hsieh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NM8RHOD300
Name of Grantee:  HTC Corporation
Equipment Class: Digital Transmission System
Notes: PDA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.071  

Collocated transmitter operating configurations have been evaluated as described in this filing; other collocation configurations require separate evaluation. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22 Head: 0.876 W/kg, Body-worn: 1.26 W/kg; Part 24 Head: 1.16 W/kg, Body-worn: 0.581 W/kg; Part 15 Body-worn: 0.031 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: