FCC ID NMAM1YY1021

Rugged Industrial PDA

by Grayhill Inc

Grantee Code: NMA   Product Code: M1YY1021
Latest application date: 2006-12-13

FCC ID Device Details

FCC IDNMAM1YY1021
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNMA
Product CodeM1YY1021
Applicant BusinessGrayhill Inc 🇺🇸
Related Domains grayhill.com
Equipment ClassRugged Industrial PDA
Test FirmRadiometrics Midwest Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2006-12-13
2402-2480 MHzOriginal Equipment2006-12-13

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2006-12-13PDF 183.6 KB
Internal PhotosInternal Photos2006-12-13PDF 135.9 KB
External PhotosExternal Photos2006-12-13PDF 84.4 KB
FCC ID LabelID Label/Location Info2006-12-13PDF 202.6 KB
Block DiagramBlock Diagram2006-12-13PDF 20.9 KB
Operational DescriptionOperational Description2006-12-13PDF 16.9 KB
Test Setup PhotosTest Setup Photos2006-12-13PDF 868.4 KB
Test ReportTest Report2006-12-13PDF 230.4 KB
Confidential LetterCover Letter(s)2006-12-13PDF 25.7 KB
RF Exposure InformationRF Exposure Info2006-12-13PDF 3 MB
Schematics Metadata onlySchematicsPDF 1.4 MB

Application Information

Application IDCSJPGwV9KSMIxUiUTnw7qw==
Final Action Date2006-12-13
Application PurposeOriginal Equipment
Applicant FRN0004277307
ModelM1YY1021
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRugged Industrial PDA
Responsible PartyRobert W Chiocca, Project Manager, robert_chiocca@grayhill.com , 708 482 2327
Test FirmJoseph Strzelecki, Radiometrics Midwest Corp., joe@radiomet.com , 8152930772
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is conducted. The device must not be co-located or operating in conjunction with any other antenna or transmitter except as indicted in the certification filing. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Body 0.216 W/kg

Applications

Application IDDatePurpose
CSJPGwV9KSMIxUiUTnw7qw==2006-12-13Original Equipment
9PW8HHiGtkVaC+6SZXq/pQ==2006-12-13Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000400015C
2412-2462 MHz0.232000015C

Grants

TCB Grant - Application CSJPGwV9KSMIxUiUTnw7qw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/13/2006

Application Dated: 12/13/2006
Grayhill Inc
561 Hillgrove Avenue
LaGrange, IL 60525-5997
 
Attention: Robert W Chiocca , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NMAM1YY1021
Name of Grantee:  Grayhill Inc
Equipment Class: Digital Transmission System
Notes: Rugged Industrial PDA
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.232  

Output Power is conducted. The device must not be co-located or operating in conjunction with any other antenna or transmitter except as indicted in the certification filing. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Body 0.216 W/kg

EAS Grant - Application CSJPGwV9KSMIxUiUTnw7qw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Grayhill Inc
561 Hillgrove Avenue
LaGrange, IL 60525-5997
United States
  Date of Grant: 12/13/2006

Application Dated: 12/13/2006
 
Attention: Robert W Chiocca , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NMAM1YY1021
Name of Grantee:  Grayhill Inc
Equipment Class: Digital Transmission System
Notes: Rugged Industrial PDA
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.232  

Output Power is conducted. The device must not be co-located or operating in conjunction with any other antenna or transmitter except as indicted in the certification filing. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Body 0.216 W/kg



TCB Grant - Application 9PW8HHiGtkVaC+6SZXq/pQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/13/2006

Application Dated: 12/13/2006
Grayhill Inc
561 Hillgrove Avenue
LaGrange, IL 60525-5997
 
Attention: Robert W Chiocca , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NMAM1YY1021
Name of Grantee:  Grayhill Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Rugged Industrial PDA
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0004  


EAS Grant - Application 9PW8HHiGtkVaC+6SZXq/pQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Grayhill Inc
561 Hillgrove Avenue
LaGrange, IL 60525-5997
United States
  Date of Grant: 12/13/2006

Application Dated: 12/13/2006
 
Attention: Robert W Chiocca , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NMAM1YY1021
Name of Grantee:  Grayhill Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Rugged Industrial PDA
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0004  



Mail To: