FCC ID NRR-S4X
PCS Handset
by Siemens Mobile Phones A/S
Grantee Code: NRR Product Code: S4X
Latest application date: 2001-02-08
FCC ID Device Details
| FCC ID | NRR-S4X |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | NRR |
| Product Code | S4X |
| Applicant Business | Siemens Mobile Phones A/S 🇩🇰 |
| Related Domains | |
| Equipment Class | PCS Handset |
| Test Firm | Communication Certification Lab. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850-1910 MHz | Original Equipment | 2001-02-08 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual wording | RF Exposure Info | 2001-02-08 | PDF 204.2 KB |
| User manual CTIA wording | RF Exposure Info | 2001-02-08 | PDF 204.9 KB |
| Users Manaual | Users Manual | 2001-02-08 | PDF 1.5 MB |
| only page two with new SAR text | Users Manual | 2001-02-08 | PDF 203.6 KB |
| Internal Photos | Internal Photos | 2001-02-08 | PDF 968.8 KB |
| External Photos | External Photos | 2001-02-08 | PDF 662.7 KB |
| Label and Label Placement | ID Label/Location Info | 2001-02-08 | PDF 168.4 KB |
| Test Setup Photos | Test Setup Photos | 2001-02-08 | PDF 747.5 KB |
| Body Worn Sar Test Report | RF Exposure Info | 2001-02-08 | PDF 1.4 MB |
| Body Worn Sar Test report | RF Exposure Info | 2001-02-08 | PDF 1.5 MB |
| Test Report | Test Report | 2001-02-08 | PDF 153.4 KB |
| clarifying of measured EIRP | Test Report | 2001-02-08 | PDF 19 KB |
| Request for confidentiality | Cover Letter(s) | 2001-02-08 | PDF 234 KB |
| RF Exposure Info | RF Exposure Info | 2001-02-08 | PDF 5.4 KB |
| Response to FCC Questions | RF Exposure Info | 2001-02-08 | PDF 43.5 KB |
| Revised SAR Report | RF Exposure Info | 2001-02-08 | PDF 525.9 KB |
| SAR Report for S40 | RF Exposure Info | 2001-02-08 | PDF 268.7 KB |
| SAR Report for S42 | RF Exposure Info | 2001-02-08 | PDF 298.4 KB |
| Block Diagram Metadata only | Block Diagram | PDF 35.9 KB | |
| Schematics Metadata only | Schematics | PDF 1.8 MB | |
| Info required for Certification Metadata only | Operational Description | PDF 110.1 KB | |
| partslist for Siemens S40 Metadata only | Parts List/Tune Up Info | PDF 33.4 KB | |
| tune up procedure and max output Metadata only | Parts List/Tune Up Info | PDF 20.5 KB |
Application Information
| Application ID | lZZ3c3Vu0ON/c1QxJ02ejg== |
|---|---|
| Final Action Date | 2001-02-08 |
| Application Purpose | Original Equipment |
| Applicant FRN | 9999999999 |
| Model | S4X |
| Frequency Range | 1850-1910 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | PCS Handset |
| Responsible Party | Ole Rasmussen, Project Manager, ora@dancall.dk |
| Technical Contact | Roger J Midgley, Communication Certification Laboratory, rjm@cclab.com |
| Test Firm | Scott Earl, Communication Certification Lab., sbe@cclab.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is EIRP. Device operates with an internal antenna. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the user's body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Device contains hardware support for GSM 900 MHZ and GSM 1800 MHZ functions that are no operational in U.S. territories and are not applicable to this filing. The highest reported SAR value is - Head: 0.33 W/kg; Body-worn: 1.54 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| lZZ3c3Vu0ON/c1QxJ02ejg== | 2001-02-08 | Original Equipment |
Grants
TCB Grant - Application lZZ3c3Vu0ON/c1QxJ02ejg==
This application does not exist.
EAS Grant - Application lZZ3c3Vu0ON/c1QxJ02ejg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens Mobile Phones A/S Klokkestobervej 4 Pandrup, DK9490 Denmark |
Date of Grant: 02/08/2001 Application Dated: 09/14/2000 |
| Attention: Ole Rasmussen , Project Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NRR-S4X |
| Name of Grantee: | Siemens Mobile Phones A/S |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | PCS Handset |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.589 | 274KGXW |
| Output is EIRP. Device operates with an internal antenna. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the user's body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Device contains hardware support for GSM 900 MHZ and GSM 1800 MHZ functions that are no operational in U.S. territories and are not applicable to this filing. The highest reported SAR value is - Head: 0.33 W/kg; Body-worn: 1.54 W/kg.
|
| Mail To: |