FCC ID NS9PMDDL900
2X2 MIMO 900MHz OEM DDL Module
by Microhard Systems Inc
Grantee Code: NS9 Product Code: PMDDL900
Latest application date: 2019-06-03
FCC ID Device Details
| FCC ID | NS9PMDDL900 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | NS9 |
| Product Code | PMDDL900 |
| Applicant Business | Microhard Systems Inc 🇨🇦 |
| Related Domains | |
| Equipment Class | 2X2 MIMO 900MHz OEM DDL Module |
| Test Firm | UltraTech Engineering Labs Inc |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 905-925 MHz | Original Equipment | 2019-06-03 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-06-03 | PDF 298.1 KB |
| Internal Photos | Internal Photos | 2019-06-03 | PDF 120.5 KB |
| Antenna Photos | External Photos | 2019-06-03 | PDF 1.1 MB |
| External Photos | External Photos | 2019-06-03 | PDF 90.1 KB |
| ID Label and Location Info | ID Label/Location Info | 2019-06-03 | PDF 105.2 KB |
| Test Setup Photos | Test Setup Photos | 2019-06-03 | PDF 1.5 MB |
| Test Report | Test Report | 2019-06-03 | PDF 2.9 MB |
| Using Original Test Reports | Attestation Statements | 2019-06-03 | PDF 163.8 KB |
| Part 15B | Attestation Statements | 2019-06-03 | PDF 137.3 KB |
| Agent Authorization | Cover Letter(s) | 2019-06-03 | PDF 141.8 KB |
| Confidentiality Request | Cover Letter(s) | 2019-06-03 | PDF 96.8 KB |
| Cover Letter | Cover Letter(s) | 2019-06-03 | PDF 99 KB |
| Modular Request | Cover Letter(s) | 2019-06-03 | PDF 158 KB |
| EUT MPE Evaluation | RF Exposure Info | 2019-06-03 | PDF 75 KB |
| MPE from FCC ID XMR201901EM12G | RF Exposure Info | 2019-06-03 | PDF 1.3 MB |
| MPE from FCC ID XPY2AGQN4NNN | RF Exposure Info | 2019-06-03 | PDF 544.9 KB |
| MPE from FCC ID ZMOL850GL | RF Exposure Info | 2019-06-03 | PDF 464 KB |
| Block Diagram Metadata only | Block Diagram | PDF 66.6 KB | |
| Schematics Metadata only | Schematics | PDF 139.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 105.4 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 51.2 KB |
Application Information
| Application ID | 8jHwbWDGoq3BU3BxjCFK7Q== |
|---|---|
| Final Action Date | 2019-06-03 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0007211139 |
| Model | PMDDL900 |
| Frequency Range | 905-925 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 2X2 MIMO 900MHz OEM DDL Module |
| Responsible Party | Hany Shenouda, President, Shenouda@microhardcorp.com |
| Agent | Dan Dan Dan, UltraTech Engineering Labs Inc, dan@ultratech-labs.com |
| Test Firm | Tri Luu, UltraTech Engineering Labs Inc, tri@ultratech-labs.com |
| TCB Email | vic@ultratech-labs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Single modular approval. Output power listed is maximum combined conducted. The output power is continuously variable from the value listed in this entry to 4% - 7% of the value listed. The device has 4 MHz and 8 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except in accordance with FCC multi- transmitter product procedures identified in this filing as FCC ID: XMR201901EM12G, FCC ID: XMR201903EG25G, FCC ID: XPY2AGQN4NNN or FCC ID: ZMOL850GL, using a maximum 3.0 dBi dipole antenna. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8jHwbWDGoq3BU3BxjCFK7Q== | 2019-06-03 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 8jHwbWDGoq3BU3BxjCFK7Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Ultratech Engineering Labs Inc. 3000 Bristol Circle Oakville Ontario, L6H 6G4 Canada |
Date of Grant: 06/03/2019 Application Dated: 06/03/2019 |
| Microhard Systems Inc |
| 150 Country Hills Landing NW |
| Calgary, AB, T3K 5P3 Canada |
| Attention: Hany Shenouda , President |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NS9PMDDL900 |
| Name of Grantee: | Microhard Systems Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | 2X2 MIMO 900MHz OEM DDL Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 36 MO | 15C | 905.0 - 925.0 | 0.34041 | ||
| 36 MO | 15C | 907.0 - 923.0 | 0.69502 | ||
| 36 MO | 15C | 905.0 - 925.0 | 1.0 | ||
| 36 MO | 15C | 907.0 - 923.0 | 1.0 |
| Single modular approval. Output power listed is maximum combined conducted. The output power is continuously variable from the value listed in this entry to 4% - 7% of the value listed. The device has 4 MHz and 8 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except in accordance with FCC multi- transmitter product procedures identified in this filing as FCC ID: XMR201901EM12G, FCC ID: XMR201903EG25G, FCC ID: XPY2AGQN4NNN or FCC ID: ZMOL850GL, using a maximum 3.0 dBi dipole antenna. |
| 36: | Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 8jHwbWDGoq3BU3BxjCFK7Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Microhard Systems Inc 150 Country Hills Landing NW Calgary, AB, T3K 5P3 Canada |
Date of Grant: 06/03/2019 Application Dated: 06/03/2019 |
| Attention: Hany Shenouda , President |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NS9PMDDL900 |
| Name of Grantee: | Microhard Systems Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | 2X2 MIMO 900MHz OEM DDL Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 36 MO | 15C | 905.0 - 925.0 | 0.34041 | ||
| 36 MO | 15C | 907.0 - 923.0 | 0.69502 | ||
| 36 MO | 15C | 905.0 - 925.0 | 1.0 | ||
| 36 MO | 15C | 907.0 - 923.0 | 1.0 |
| Single modular approval. Output power listed is maximum combined conducted. The output power is continuously variable from the value listed in this entry to 4% - 7% of the value listed. The device has 4 MHz and 8 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except in accordance with FCC multi- transmitter product procedures identified in this filing as FCC ID: XMR201901EM12G, FCC ID: XMR201903EG25G, FCC ID: XPY2AGQN4NNN or FCC ID: ZMOL850GL, using a maximum 3.0 dBi dipole antenna. |
| 36: | Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |