FCC ID NTAALLWM1
Allegro Wall Mount
by ST Engineering Telematics Wireless Ltd.
Grantee Code: NTA Product Code: ALLWM1
Latest application date: 2022-07-25
FCC ID Device Details
| FCC ID | NTAALLWM1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | NTA |
| Product Code | ALLWM1 |
| Applicant Business | ST Engineering Telematics Wireless Ltd. 🇮🇱 |
| Related Domains | |
| Equipment Class | Allegro Wall Mount |
| Test Firm | Hermon Laboratories Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450-470 MHz | Original Equipment | 2022-07-25 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2022-07-25 | PDF 717.2 KB |
| Internal Photos | Internal Photos | 2023-01-19 | PDF 738.1 KB |
| External Photos | External Photos | 2022-07-25 | PDF 493 KB |
| ID Label/Location Info | ID Label/Location Info | 2022-07-25 | PDF 466 KB |
| Test Setup Photos | Test Setup Photos | 2022-07-25 | PDF 276.8 KB |
| Test Report | Test Report | 2022-07-25 | PDF 2.4 MB |
| Confidentiality | Cover Letter(s) | 2022-07-25 | PDF 122.9 KB |
| Cover Letter | Cover Letter(s) | 2022-07-25 | PDF 47.8 KB |
| Declaration of authorization | Cover Letter(s) | 2022-07-25 | PDF 99.1 KB |
| KDB634817 letter | Cover Letter(s) | 2022-07-25 | PDF 206.4 KB |
| RF Exposure Info | RF Exposure Info | 2022-07-25 | PDF 355.7 KB |
| Block Diagram Metadata only | Block Diagram | PDF 456.2 KB | |
| Schematics Metadata only | Schematics | PDF 421.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 1 MB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 589.3 KB |
Application Information
| Application ID | 5HTqs7tIVyROVtUe4O0BWQ== |
|---|---|
| Final Action Date | 2022-07-25 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0009953373 |
| Model | ALLWM1 |
| Frequency Range | 450-470 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Allegro Wall Mount |
| Responsible Party | Roman Sternberg, VP Marketing & Business Development, romans@telematics-wireless.com |
| Technical Contact | Michael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com |
| Non-Technical Contact | Roman Sternberg, ST Engineering Telematics Wireless Ltd., romans@telematics-wireless.com |
| Test Firm | George Shleimovich, Hermon Laboratories Ltd., George@HERMONLABS.com |
| TCB Email | certification@telefication.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/19/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 5HTqs7tIVyROVtUe4O0BWQ== | 2022-07-25 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 5HTqs7tIVyROVtUe4O0BWQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 07/25/2022 Application Dated: 07/22/2022 |
| ST Engineering Telematics Wireless Ltd. |
| 26 Hamelacha Street |
| Holon 5811801, Israel |
| Attention: Roman Sternberg , VP Marketing & Business Development |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NTAALLWM1 |
| Name of Grantee: | ST Engineering Telematics Wireless Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Allegro Wall Mount |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 2.09 | 277.0 Hz | 4K94F1D |
| Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. |
EAS Grant - Application 5HTqs7tIVyROVtUe4O0BWQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ST Engineering Telematics Wireless Ltd. 26 Hamelacha Street Holon 5811801, Israel |
Date of Grant: 07/25/2022 Application Dated: 07/22/2022 |
| Attention: Roman Sternberg , VP Marketing & Business Development |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NTAALLWM1 |
| Name of Grantee: | ST Engineering Telematics Wireless Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Allegro Wall Mount |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 2.09 | 277.0 Hz | 4K94F1D |
| Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. |
| Mail To: |