FCC ID NVRBDA610-S8

SMR 800 Bi-Directional Amplifier

by Westell, Inc.

Grantee Code: NVR   Product Code: BDA610S8
Latest application date: 2017-03-30

Device Images

FCC ID Device Details

FCC IDNVRBDA610-S8
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeNVR
Product CodeBDA610S8
Applicant BusinessWestell, Inc. 🇺🇸
Related Domains westell.com
Equipment ClassSMR 800 Bi-Directional Amplifier
Test FirmRadiometrics Midwest Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
817-824 MHzOriginal Equipment2017-03-30
806-817 MHzOriginal Equipment2017-03-30

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2017-03-30PDF 1.2 MB
Int PhotosInternal Photos2017-06-30PDF 1.3 MB
Ext PhotosExternal Photos2017-03-30PDF 434.6 KB
FCC ID LabelID Label/Location Info2017-03-30PDF 329.6 KB
Test ReportTest Report2017-03-30PDF 1.3 MB
Test ReportTest Report2017-03-30PDF 991.8 KB
Attestation StatementAttestation Statements2017-03-30PDF 112.5 KB
Agency LetterCover Letter(s)2017-03-30PDF 52.6 KB
Confidentiality LetterCover Letter(s)2017-03-30PDF 100 KB
Block Diagram Metadata onlyBlock DiagramPDF 127.1 KB
Schematics Metadata onlySchematicsPDF 321.5 KB
Operation Description Metadata onlyOperational DescriptionPDF 16.4 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 146.4 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 98.2 KB

Application Information

Application IDiQCIiMtfQk8vxHD+rEvdZw==
Final Action Date2017-03-30
Application PurposeOriginal Equipment
Applicant FRN0010374171
ModelBDA610-S8
Frequency Range817-824 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionSMR 800 Bi-Directional Amplifier
Responsible PartyJoseph K Gage, Compliance Engineer, jgage@westell.com , 630-375-4724
Test FirmJoseph Strzelecki, Radiometrics Midwest Corp., joe@radiomet.com , 8152930772
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/30/2017
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted at antenna terminal. This booster is authorized for use as an in-building DAS only. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
iQCIiMtfQk8vxHD+rEvdZw==2017-03-30Original Equipment
2oM57GnVI1zBEj48XRoItA==2017-03-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-817 MHz0.794AmpF3E9
806-817 MHz0.794AmpF1D9
806-817 MHz0.794AmpF1E9
817-824 MHz0.813AmpF9W90S
817-824 MHz0.813AmpG7W90S
851-862 MHz0.759AmpF3E9
851-862 MHz0.759AmpF1D9
851-862 MHz0.759AmpF1E9
862-869 MHz0.794AmpF9W90S
862-869 MHz0.794AmpG7W90S

Grants

TCB Grant - Application iQCIiMtfQk8vxHD+rEvdZw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 03/30/2017

Application Dated: 03/30/2017
Westell, Inc.
750 North Commons Drive
Aurora, IL 60504
 
Attention: Joseph Gage , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NVRBDA610-S8
Name of Grantee:  Westell, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: SMR 800 Bi-Directional Amplifier
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90S 817.0  -  824.0 0.813  Amp F9W
90S 817.0  -  824.0 0.813  Amp G7W
90S 862.0  -  869.0 0.794  Amp F9W
90S 862.0  -  869.0 0.794  Amp G7W

Output power listed is conducted at antenna terminal. This booster is authorized for use as an in-building DAS only. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application iQCIiMtfQk8vxHD+rEvdZw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Westell, Inc.
750 North Commons Drive
Aurora, IL 60504
United States
  Date of Grant: 03/30/2017

Application Dated: 03/30/2017
 
Attention: Joseph Gage , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NVRBDA610-S8
Name of Grantee:  Westell, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: SMR 800 Bi-Directional Amplifier
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90S 817.0  -  824.0 0.813  Amp F9W
90S 817.0  -  824.0 0.813  Amp G7W
90S 862.0  -  869.0 0.794  Amp F9W
90S 862.0  -  869.0 0.794  Amp G7W

Output power listed is conducted at antenna terminal. This booster is authorized for use as an in-building DAS only. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



TCB Grant - Application 2oM57GnVI1zBEj48XRoItA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 03/30/2017

Application Dated: 03/30/2017
Westell, Inc.
750 North Commons Drive
Aurora, IL 60504
 
Attention: Joseph Gage , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NVRBDA610-S8
Name of Grantee:  Westell, Inc.
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: SMR 800 Bi-Directional Amplifier
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  817.0 0.794  Amp F3E
90 806.0  -  817.0 0.794  Amp F1D
90 806.0  -  817.0 0.794  Amp F1E
90 851.0  -  862.0 0.759  Amp F3E
90 851.0  -  862.0 0.759  Amp F1D
90 851.0  -  862.0 0.759  Amp F1E

Output power listed is conducted at antenna terminal. This booster is authorized for use as an in-building DAS only. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application 2oM57GnVI1zBEj48XRoItA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Westell, Inc.
750 North Commons Drive
Aurora, IL 60504
United States
  Date of Grant: 03/30/2017

Application Dated: 03/30/2017
 
Attention: Joseph Gage , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  NVRBDA610-S8
Name of Grantee:  Westell, Inc.
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: SMR 800 Bi-Directional Amplifier
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  817.0 0.794  Amp F3E
90 806.0  -  817.0 0.794  Amp F1D
90 806.0  -  817.0 0.794  Amp F1E
90 851.0  -  862.0 0.759  Amp F3E
90 851.0  -  862.0 0.759  Amp F1D
90 851.0  -  862.0 0.759  Amp F1E

Output power listed is conducted at antenna terminal. This booster is authorized for use as an in-building DAS only. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



Mail To: