FCC ID NXW-RF630R
UHF RFID Reader
by Siemens AG
Grantee Code: NXW Product Code: RF630R
Latest application date: 2010-09-22
FCC ID Device Details
| FCC ID | NXW-RF630R |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | NXW |
| Product Code | RF630R |
| Applicant Business | Siemens AG 🇩🇪 |
| Related Domains | |
| Equipment Class | UHF RFID Reader |
| Test Firm | TUV SUD Product Service GmbH PS-EMC-STR |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 902.25-927.75 MHz | Class II permissive change or modification of presently authorized equipment | 2010-09-22 |
| 902.25-927.75 MHz | Class II permissive change or modification of presently authorized equipment | 2010-02-23 |
| 902.25-927.75 MHz | Original Equipment | 2009-03-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2010-02-23 | PDF 697.7 KB |
| User Manual II | Users Manual | 2010-02-23 | PDF 780.5 KB |
| User Manual | Users Manual | 2009-03-23 | PDF 747.5 KB |
| Internal Photos | Internal Photos | 2009-03-23 | PDF 1.1 MB |
| External Photos | External Photos | 2009-03-23 | PDF 441.5 KB |
| ID Label Location Info | ID Label/Location Info | 2009-03-23 | PDF 187.3 KB |
| Test Setup Photos | Test Setup Photos | 2010-09-22 | PDF 463.1 KB |
| Test Setup Photos | Test Setup Photos | 2010-02-23 | PDF 729.3 KB |
| Test Setup Photos | Test Setup Photos | 2009-03-23 | PDF 227.7 KB |
| Test Equipment List | Test Report | 2010-09-22 | PDF 13.3 KB |
| Test Report | Test Report | 2010-09-22 | PDF 2 MB |
| Annex to Test Report | Test Report | 2010-02-23 | PDF 99.5 KB |
| Test Report | Test Report | 2010-02-23 | PDF 1.5 MB |
| Test Report | Test Report | 2009-03-23 | PDF 1.4 MB |
| Cover Letter | Cover Letter(s) | 2010-09-22 | PDF 758.8 KB |
| Power of Attorney | Cover Letter(s) | 2010-09-22 | PDF 795.8 KB |
| Request for Confidential | Cover Letter(s) | 2010-09-22 | PDF 534.2 KB |
| Authorization Letter | Cover Letter(s) | 2010-02-23 | PDF 792.3 KB |
| Request for Confidentiality | Cover Letter(s) | 2010-02-23 | PDF 730.1 KB |
| Authorization Letter I | Cover Letter(s) | 2009-03-23 | PDF 517.5 KB |
| Authorization Letter II | Cover Letter(s) | 2009-03-23 | PDF 3.1 MB |
| Request for Confidentiality | Cover Letter(s) | 2009-03-23 | PDF 301.8 KB |
| MPE | RF Exposure Info | 2010-09-22 | PDF 49 KB |
Application Information
| Application ID | ghb9+l8MmSgrbcs09Gs2sw== |
|---|---|
| Final Action Date | 2010-09-22 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0006191076 |
| Model | -RF630R |
| Frequency Range | 902.25-927.75 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | UHF RFID Reader |
| Responsible Party | Dieter Horst, R&D; Manager, Dieter.horst@siemens.com |
| Agent | Johann Johann Johann, TÜV SÜD SENTON GmbH, senton@tuev-sued.de |
| Test Firm | Rainer Heller, TUV SUD Product Service GmbH PS-EMC-STR, rainer.heller@tuev-sued.de |
| TCB Email | Dollitz.Uwe@phoenix-testlab.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class 2 Permissive Change to add antennas as documented in this filing. Power listed is peak conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm for antenna RF640A and 30 cm for antenna RF642A from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ghb9+l8MmSgrbcs09Gs2sw== | 2010-09-22 | Class II permissive change or modification of presently authorized equipment |
| 8lcksDOY0Mhh81PeDYstRg== | 2010-02-23 | Class II permissive change or modification of presently authorized equipment |
| 8sYSu3ymb4+pBCD+UjFCDA== | 2009-03-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 902.25-927.75 MHz | 0.7950000 | 15C |
Grants
TCB Grant - Application ghb9+l8MmSgrbcs09Gs2sw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/22/2010 Application Dated: 09/22/2010 |
| Siemens AG |
| Siemensstrasse 2-4 |
| I IA SC IC |
| Fuerth, 90766 Germany |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID Reader |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Class 2 Permissive Change to add antennas as documented in this filing. Power listed is peak conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm for antenna RF640A and 30 cm for antenna RF642A from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application ghb9+l8MmSgrbcs09Gs2sw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Siemensstrasse 2-4 I IA SC IC Fuerth, 90766 Germany |
Date of Grant: 09/22/2010 Application Dated: 09/22/2010 |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID Reader |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Class 2 Permissive Change to add antennas as documented in this filing. Power listed is peak conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm for antenna RF640A and 30 cm for antenna RF642A from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/23/2009 Application Dated: 03/23/2009 |
| Siemens AG |
| Siemensstrasse 2-4 |
| I IA SC IC |
| Fuerth, 90766 Germany |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID READER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Output Power listed is conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 8sYSu3ymb4+pBCD+UjFCDA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Siemensstrasse 2-4 I IA SC IC Fuerth, 90766 Germany |
Date of Grant: 03/23/2009 Application Dated: 03/23/2009 |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID READER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Output Power listed is conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 02/23/2010 Application Dated: 02/23/2010 |
| Siemens AG |
| Siemensstrasse 2-4 |
| I IA SC IC |
| Fuerth, 90766 Germany |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID READER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Class II filing adds new antenna as described in the filing. Output Power listed is conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 8lcksDOY0Mhh81PeDYstRg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Siemensstrasse 2-4 I IA SC IC Fuerth, 90766 Germany |
Date of Grant: 02/23/2010 Application Dated: 02/23/2010 |
| Attention: Dieter Horst , R&D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | NXW-RF630R |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | UHF RFID READER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.25 - 927.75 | 0.795 |
| Class II filing adds new antenna as described in the filing. Output Power listed is conducted. This device must be professionally installed. The only antennas approved for use with this device are those documented in the filing, and must be installed in the manner specified therein.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |