FCC ID O34-ELITE780MX

Elite 780 MOBITEX

by Ingenico

Grantee Code: O34   Product Code: ELITE780MX
Latest application date: 2001-03-15

FCC ID Device Details

FCC IDO34-ELITE780MX
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeO34
Product CodeELITE780MX
Applicant BusinessIngenico 🇨🇦
Equipment ClassElite 780 MOBITEX
Test FirmUltraTech Engineering Labs Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
896-901 MHzOriginal Equipment2001-03-15

Exhibits

DocumentTypeAvailableFile
Elite 780 MOBITEX users manualUsers Manual2001-03-15PDF 302.6 KB
Elite 780 MOBITEX internal photosInternal Photos2001-03-15PDF 2.2 MB
Elite 780 MOBITEX and antenna external photosExternal Photos2001-03-15PDF 476.8 KB
FCC ID label and location infoID Label/Location Info2001-03-15PDF 106.2 KB
ERPTest Report2001-03-15PDF 30.8 KB
Elite 780 MOBITEX SAR test reportRF Exposure Info2001-03-15PDF 1 MB
TEST REPORTSTest Report2001-03-15PDF 3.3 MB
ATTESTATION STATEMENTSAttestation Statements2001-03-15PDF 103.1 KB
COVER LETTERSCover Letter(s)2001-03-15PDF 142.4 KB
Ultratech cover letter and authoriation letter and RIMs letterCover Letter(s)2001-03-15PDF 320.4 KB
Correspondence 17943 answer to questions 3 and 4RF Exposure Info2001-03-15PDF 10.5 KB
Calibration Procedure and Manual Metadata onlyParts List/Tune Up InfoPDF 197 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 47.7 KB
SCHEMATICS Metadata onlySchematicsPDF 614.6 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 117.9 KB
Modulation Wavetrain and Detailed Device Description Metadata onlyParts List/Tune Up InfoPDF 2.5 MB
Parts List and Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 2.2 MB

Application Information

Application IDbDyukL2ti45EcGNou9lOuA==
Final Action Date2001-03-15
Application PurposeOriginal Equipment
Applicant FRN0008628687
ModelELITE780MX
Frequency Range896-901 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionElite 780 MOBITEX
Responsible PartyKandeepan K., (416) 245-6700
AgentTri Tri Tri, Ultratech Engineering Labs Inc., tri.luu@sympatico.ca , 1-877-765-4173
Technical ContactTri M Luu, Ultratech Engineering Labs Inc., tri.luu@sympatico.ca , 1-877-765-4173
Non-Technical ContactTri M Luu, Ultratech Engineering Labs Inc., tri.luu@sympatico.ca , 1-877-765-4173
Test FirmTri Luu, UltraTech Engineering Labs Inc., tri@ultratech-labs.com , 877-747-6381
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP. This hand-held point-of-sales device is for operation in a person's hands only and has been tested in applicable configurations for SAR compliance. The maximum conducted output at the antenna terminal must not exceed the conditions tested for SAR compliance. Device must operate with a duty factor not exceeding 15 %, controlled by factory firmware for satisfying RF exposure compliance. Users should be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value for the body is 1.08 W/kg at 15% duty factor.

Applications

Application IDDatePurpose
bDyukL2ti45EcGNou9lOuA==2001-03-15Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
896-901 MHz1.07000000.0001500000%10K0F1D90

Grants

TCB Grant - Application bDyukL2ti45EcGNou9lOuA==

This application does not exist.

EAS Grant - Application bDyukL2ti45EcGNou9lOuA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ingenico
79 Torbarrie Road
Toronto, Ontario, M3L 1G5
Canada
  Date of Grant: 03/15/2001

Application Dated: 12/08/2000
 
Attention: Kandeepan K.

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O34-ELITE780MX
Name of Grantee:  Ingenico
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Elite 780 MOBITEX
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 896.0  -  901.0 1.07 0.00015  % 10K0F1D

Output is ERP. This hand-held point-of-sales device is for operation in a person's hands only and has been tested in applicable configurations for SAR compliance. The maximum conducted output at the antenna terminal must not exceed the conditions tested for SAR compliance. Device must operate with a duty factor not exceeding 15 %, controlled by factory firmware for satisfying RF exposure compliance. Users should be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value for the body is 1.08 W/kg at 15% duty factor.



Mail To:
Tri Luu, Authorized Agent
Ultratech Engineering Labs Inc.
3000 Bristol Circle
Oakville, Ontario, L6H 6G4
Canada