FCC ID O55003020
4G Mi-Fi
by SWAGTEK
Grantee Code: O55 Product Code: 003020
Latest application date: 2020-10-29
FCC ID Device Details
| FCC ID | O55003020 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | O55 |
| Product Code | 003020 |
| Applicant Business | SWAGTEK 🇺🇸 |
| Related Domains | |
| Equipment Class | 4G Mi-Fi |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2020-10-29 |
| 699.7-715.3 MHz | Original Equipment | 2020-10-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user_manual | Users Manual | 2020-10-29 | PDF 1.2 MB |
| Internal_Photos | Internal Photos | 2020-10-29 | PDF 1.2 MB |
| External_Photos | External Photos | 2020-10-29 | PDF 4.6 MB |
| Label_and_Label_Location | ID Label/Location Info | 2020-10-29 | PDF 790.1 KB |
| Test_Setup_Photos | Test Setup Photos | 2020-10-29 | PDF 1.5 MB |
| Test_Setup_Photos | Test Setup Photos | 2020-10-29 | PDF 656.9 KB |
| Appendix A | Test Report | 2020-10-29 | PDF 3.6 MB |
| Appendix B-1 | Test Report | 2020-10-29 | PDF 4.9 MB |
| Appendix B-2 | Test Report | 2020-10-29 | PDF 5.5 MB |
| Appendix C-1 | Test Report | 2020-10-29 | PDF 5.1 MB |
| Appendix C-2 | Test Report | 2020-10-29 | PDF 5.7 MB |
| Appendix D-1 | Test Report | 2020-10-29 | PDF 3.3 MB |
| Appendix D-2 | Test Report | 2020-10-29 | PDF 4 MB |
| Appendix E-1 | Test Report | 2020-10-29 | PDF 2.8 MB |
| Appendix E-2 | Test Report | 2020-10-29 | PDF 4.5 MB |
| Appendix F-1 | Test Report | 2020-10-29 | PDF 3.6 MB |
| Appendix F-2 | Test Report | 2020-10-29 | PDF 3.7 MB |
| Appendix G | Test Report | 2020-10-29 | PDF 3 MB |
| Appendix H | Test Report | 2020-10-29 | PDF 3.6 MB |
| LCS200730059AEA_2.4G WIFI | Test Report | 2020-10-29 | PDF 1.1 MB |
| LCS200730059AEC_GSM | Test Report | 2020-10-29 | PDF 5.4 MB |
| LCS200730059AED_WCDMA | Test Report | 2020-10-29 | PDF 4.6 MB |
| LCS200730059AEE_LTE | Test Report | 2020-10-29 | PDF 759.6 KB |
| Agent_Authorization | Cover Letter(s) | 2020-10-29 | PDF 53 KB |
| Agent_Authorization_Rev_1.0 | Cover Letter(s) | 2020-10-29 | PDF 53 KB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2020-10-29 | PDF 49.8 KB |
| FCC_Long_Term_Only_Confidentiality | Cover Letter(s) | 2020-10-29 | PDF 50.2 KB |
| LCS200730059AEB SAR REPORT-1 | RF Exposure Info | 2020-10-29 | PDF 4 MB |
| LCS200730059AEB SAR REPORT-2 | RF Exposure Info | 2020-10-29 | PDF 5.4 MB |
| LCS200730059AEB SAR REPORT-3 | RF Exposure Info | 2020-10-29 | PDF 5.3 MB |
| LCS200730059AEB SAR REPORT-4 | RF Exposure Info | 2020-10-29 | PDF 5 MB |
| Block_diagram Metadata only | Block Diagram | PDF 131.2 KB | |
| SCH Metadata only | Schematics | PDF 510.1 KB | |
| Operation_Description Metadata only | Operational Description | PDF 120.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 115.3 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 161.3 KB |
Application Information
| Application ID | klCer8ayI1/dUwcwFOc9YQ== |
|---|---|
| Final Action Date | 2020-10-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0021846670 |
| Model | 003020 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 4G Mi-Fi |
| Responsible Party | Charles Cheng, Manager, legal@swagtek.com |
| Technical Contact | SWAGTEK, charles.c@swagtek.com |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, hotspot and simultaneous transmission use conditions is 0.06W/kg, 0.06W/kg and 1.53W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| klCer8ayI1/dUwcwFOc9YQ== | 2020-10-29 | Original Equipment |
| +KTpYsbKyvhqX2+dM9F4Dw== | 2020-10-29 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 699.7-715.3 MHz | 0.09 | 2.5ppm | 1M08W7D | 27 |
| 700.5-714.5 MHz | 0.086 | 2.5ppm | 2M68G7D | 27 |
| 704-711 MHz | 0.082 | 2.5ppm | 8M93G7D | 27 |
| 704-711 MHz | 0.077 | 2.5ppm | 8M94W7D | 27 |
| 709-711 MHz | 0.145 | 1.25ppm | 8M99G7D | 27 |
| 709-711 MHz | 0.131 | 1.25ppm | 8M99W7D | 27 |
| 779.5-784.5 MHz | 0.117 | 2.5ppm | 4M48G7D | 27 |
| 779.5-784.5 MHz | 0.138 | 2.5ppm | 4M48W7D | 27 |
| 782 MHz | 0.083 | 2.5ppm | 8M93G7D | 27 |
| 782 MHz | 0.125 | 2.5ppm | 8M92W7D | 27 |
| 825.5-847.5 MHz | 0.083 | 2.5ppm | 2M68G7D | 22H |
| 825.5-847.5 MHz | 0.092 | 2.5ppm | 2M68W7D | 22H |
| 826.4-846.6 MHz | 0.104 | 2.5ppm | 4M15F9W | 22H |
| 829-844 MHz | 0.08 | 2.5ppm | 8M95G7D | 22H |
| 829-844 MHz | 0.09 | 2.5ppm | 8M95W7D | 22H |
| 1712.5-1752.5 MHz | 0.2 | 2.5ppm | 4M48G7D | 27 |
| 1712.5-1752.5 MHz | 0.156 | 2.5ppm | 4M48W7D | 27 |
| 1720-1745 MHz | 0.193 | 2.5ppm | 17M9G7D | 27 |
| 1720-1745 MHz | 0.147 | 2.5ppm | 17M8W7D | 27 |
| 1850.2-1909.8 MHz | 0.218 | 2.5ppm | 243KG7W | 24E |
| 1852.4-1907.6 MHz | 0.192 | 2.5ppm | 4M19F9W | 24E |
| 1857.5-1902.5 MHz | 0.094 | 2.5ppm | 13M4W7D | 24E |
| 1857.5-1902.5 MHz | 0.118 | 2.5ppm | 13M4G7D | 24E |
| 1860-1900 MHz | 0.117 | 2.5ppm | 17M9G7D | 24E |
| 1860-1900 MHz | 0.075 | 2.5ppm | 17M9W7D | 24E |
| 2412-2462 MHz | 0.0210000 | 15C | ||
| 2507.5-2562.5 MHz | 0.091 | 2.5ppm | 13M5W7D | 27 |
| 2510-2560 MHz | 0.113 | 2.5ppm | 17M9G7D | 27 |
| 2510-2560 MHz | 0.089 | 2.5ppm | 17M9W7D | 27 |
Grants
TCB Grant - Application klCer8ayI1/dUwcwFOc9YQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 10/29/2020 Application Dated: 10/29/2020 |
| SWAGTEK |
| 10205 NW 19th Street STE101 |
| Miami, FL 33172 |
| Attention: Charles Cheng , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O55003020 |
| Name of Grantee: | SWAGTEK |
| Equipment Class: | Digital Transmission System |
| Notes: | 4G Mi-Fi |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.021 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, hotspot and simultaneous transmission use conditions is 0.06W/kg, 0.06W/kg and 1.53W/kg respectively. |
EAS Grant - Application klCer8ayI1/dUwcwFOc9YQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SWAGTEK 10205 NW 19th Street STE101 Miami, FL 33172 United States |
Date of Grant: 10/29/2020 Application Dated: 10/29/2020 |
| Attention: Charles Cheng , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O55003020 |
| Name of Grantee: | SWAGTEK |
| Equipment Class: | Digital Transmission System |
| Notes: | 4G Mi-Fi |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.021 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, hotspot and simultaneous transmission use conditions is 0.06W/kg, 0.06W/kg and 1.53W/kg respectively. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 10/29/2020 Application Dated: 10/29/2020 |
| SWAGTEK |
| 10205 NW 19th Street STE101 |
| Miami, FL 33172 |
| Attention: Charles Cheng , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O55003020 |
| Name of Grantee: | SWAGTEK |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | 4G Mi-Fi |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.079 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.212 | 2.5 PM | 258KG7W | |
| 24E | 1850.2 - 1909.8 | 0.631 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.218 | 2.5 PM | 243KG7W | |
| 22H | 826.4 - 846.6 | 0.104 | 2.5 PM | 4M15F9W | |
| 24E | 1852.4 - 1907.6 | 0.192 | 2.5 PM | 4M19F9W | |
| 24E | 1860.0 - 1900.0 | 0.117 | 2.5 PM | 17M9G7D | |
| 24E | 1857.5 - 1902.5 | 0.118 | 2.5 PM | 13M4G7D | |
| 24E | 1860.0 - 1900.0 | 0.075 | 2.5 PM | 17M9W7D | |
| 24E | 1857.5 - 1902.5 | 0.094 | 2.5 PM | 13M4W7D | |
| 27 | 1720.0 - 1745.0 | 0.193 | 2.5 PM | 17M9G7D | |
| 27 | 1712.5 - 1752.5 | 0.2 | 2.5 PM | 4M48G7D | |
| 27 | 1720.0 - 1745.0 | 0.147 | 2.5 PM | 17M8W7D | |
| 27 | 1712.5 - 1752.5 | 0.156 | 2.5 PM | 4M48W7D | |
| 22H | 829.0 - 844.0 | 0.08 | 2.5 PM | 8M95G7D | |
| 22H | 825.5 - 847.5 | 0.083 | 2.5 PM | 2M68G7D | |
| 22H | 829.0 - 844.0 | 0.09 | 2.5 PM | 8M95W7D | |
| 22H | 825.5 - 847.5 | 0.092 | 2.5 PM | 2M68W7D | |
| 27 | 2510.0 - 2560.0 | 0.113 | 2.5 PM | 17M9G7D | |
| 27 | 2510.0 - 2560.0 | 0.089 | 2.5 PM | 17M9W7D | |
| 27 | 2507.5 - 2562.5 | 0.091 | 2.5 PM | 13M5W7D | |
| 27 | 704.0 - 711.0 | 0.082 | 2.5 PM | 8M93G7D | |
| 27 | 700.5 - 714.5 | 0.086 | 2.5 PM | 2M68G7D | |
| 27 | 704.0 - 711.0 | 0.077 | 2.5 PM | 8M94W7D | |
| 27 | 699.7 - 715.3 | 0.09 | 2.5 PM | 1M08W7D | |
| 27 | 782.0 - 782.0 | 0.083 | 2.5 PM | 8M93G7D | |
| 27 | 779.5 - 784.5 | 0.117 | 2.5 PM | 4M48G7D | |
| 27 | 782.0 - 782.0 | 0.125 | 2.5 PM | 8M92W7D | |
| 27 | 779.5 - 784.5 | 0.138 | 2.5 PM | 4M48W7D | |
| 27 | 709.0 - 711.0 | 0.145 | 1.25 PM | 8M99G7D | |
| 27 | 709.0 - 711.0 | 0.131 | 1.25 PM | 8M99W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, hotspot, and simultaneous transmission use conditions is 1.47W/kg, 1.47W/kg and 1.53W/kg respectively. |
EAS Grant - Application +KTpYsbKyvhqX2+dM9F4Dw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SWAGTEK 10205 NW 19th Street STE101 Miami, FL 33172 United States |
Date of Grant: 10/29/2020 Application Dated: 10/29/2020 |
| Attention: Charles Cheng , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O55003020 |
| Name of Grantee: | SWAGTEK |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | 4G Mi-Fi |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.079 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.212 | 2.5 PM | 258KG7W | |
| 24E | 1850.2 - 1909.8 | 0.631 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.218 | 2.5 PM | 243KG7W | |
| 22H | 826.4 - 846.6 | 0.104 | 2.5 PM | 4M15F9W | |
| 24E | 1852.4 - 1907.6 | 0.192 | 2.5 PM | 4M19F9W | |
| 24E | 1860.0 - 1900.0 | 0.117 | 2.5 PM | 17M9G7D | |
| 24E | 1857.5 - 1902.5 | 0.118 | 2.5 PM | 13M4G7D | |
| 24E | 1860.0 - 1900.0 | 0.075 | 2.5 PM | 17M9W7D | |
| 24E | 1857.5 - 1902.5 | 0.094 | 2.5 PM | 13M4W7D | |
| 27 | 1720.0 - 1745.0 | 0.193 | 2.5 PM | 17M9G7D | |
| 27 | 1712.5 - 1752.5 | 0.2 | 2.5 PM | 4M48G7D | |
| 27 | 1720.0 - 1745.0 | 0.147 | 2.5 PM | 17M8W7D | |
| 27 | 1712.5 - 1752.5 | 0.156 | 2.5 PM | 4M48W7D | |
| 22H | 829.0 - 844.0 | 0.08 | 2.5 PM | 8M95G7D | |
| 22H | 825.5 - 847.5 | 0.083 | 2.5 PM | 2M68G7D | |
| 22H | 829.0 - 844.0 | 0.09 | 2.5 PM | 8M95W7D | |
| 22H | 825.5 - 847.5 | 0.092 | 2.5 PM | 2M68W7D | |
| 27 | 2510.0 - 2560.0 | 0.113 | 2.5 PM | 17M9G7D | |
| 27 | 2510.0 - 2560.0 | 0.089 | 2.5 PM | 17M9W7D | |
| 27 | 2507.5 - 2562.5 | 0.091 | 2.5 PM | 13M5W7D | |
| 27 | 704.0 - 711.0 | 0.082 | 2.5 PM | 8M93G7D | |
| 27 | 700.5 - 714.5 | 0.086 | 2.5 PM | 2M68G7D | |
| 27 | 704.0 - 711.0 | 0.077 | 2.5 PM | 8M94W7D | |
| 27 | 699.7 - 715.3 | 0.09 | 2.5 PM | 1M08W7D | |
| 27 | 782.0 - 782.0 | 0.083 | 2.5 PM | 8M93G7D | |
| 27 | 779.5 - 784.5 | 0.117 | 2.5 PM | 4M48G7D | |
| 27 | 782.0 - 782.0 | 0.125 | 2.5 PM | 8M92W7D | |
| 27 | 779.5 - 784.5 | 0.138 | 2.5 PM | 4M48W7D | |
| 27 | 709.0 - 711.0 | 0.145 | 1.25 PM | 8M99G7D | |
| 27 | 709.0 - 711.0 | 0.131 | 1.25 PM | 8M99W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, hotspot, and simultaneous transmission use conditions is 1.47W/kg, 1.47W/kg and 1.53W/kg respectively. |
| Mail To: |