FCC ID O6Y-UT251

UT GF251 Handset

by UTStarcom Korea Technologies Ltd.

Grantee Code: O6Y   Product Code: UT251
Latest application date: 2004-08-23

FCC ID Device Details

FCC IDO6Y-UT251
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeO6Y
Product CodeUT251
Applicant BusinessUTStarcom Korea Technologies Ltd. 🇰🇷
Related Domains utstar.com
Equipment ClassUT GF251 Handset
Test FirmSPORTON International Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2004-08-23

Exhibits

DocumentTypeAvailableFile
Revised ManualUsers Manual2004-08-23PDF 842.3 KB
Int PhotosInternal Photos2004-08-23PDF 758.3 KB
Revised Ext PhotosExternal Photos2004-08-23PDF 1 MB
LocationID Label/Location Info2004-08-23PDF 10.4 KB
SampleID Label/Location Info2004-08-23PDF 47.5 KB
Test SetupTest Setup Photos2004-08-23PDF 201.2 KB
Revised Report Part 1Test Report2004-08-23PDF 2.9 MB
Revised Report Part 2Test Report2004-08-23PDF 1.3 MB
Confid RequestCover Letter(s)2004-08-23PDF 80.2 KB
Revised Tune UpParts List/Tune Up Info2004-08-23PDF 57.5 KB
SAR Part 1RF Exposure Info2004-08-23PDF 2.8 MB
SAR Part 2RF Exposure Info2004-08-23PDF 1.9 MB
Block Metadata onlyBlock DiagramPDF 68.5 KB
Schema Metadata onlySchematicsPDF 724.3 KB
Op Description Metadata onlyOperational DescriptionPDF 83.5 KB
Parts Metadata onlyParts List/Tune Up InfoPDF 155.6 KB

Application Information

Application IDjSnhZnNdUwWEEUo7DQCgBg==
Final Action Date2004-08-23
Application PurposeOriginal Equipment
Applicant FRN0005823877
ModelUT251
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionUT GF251 Handset
Responsible PartyChung-Sung Lee, Director, R&D;, CS.Lee@utstar.com , 82-2-368-9023
Technical ContactDaniel Lee, Sporton International Inc., daniel@sporton.com.tw , +886 3 327 3459
Test FirmKathy Lin, SPORTON International Inc, kathylin@sporton.com.tw , 886-2-2696-2468
TCB Emailhotline@americanTCB.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: .56W/kg; Body-worn .11W/kg This device contains 900 MHz and 1,800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.

Applications

Application IDDatePurpose
jSnhZnNdUwWEEUo7DQCgBg==2004-08-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.2-1909.8 MHz0.36500000.0300000000300KGXW24EBC

Grants

TCB Grant - Application jSnhZnNdUwWEEUo7DQCgBg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/23/2004

Application Dated: 08/23/2004
UTStarcom Korea Technologies Ltd.
26F, Trust Tower Bldg, 275-7
Yangjae 2-Dong, Seocho-Gu,
Seoul, 137-739
South Korea
 
Attention: Chung-Sung Lee , Director, R&D

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O6Y-UT251
Name of Grantee:  UTStarcom Korea Technologies Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: UT GF251 Handset
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.365 0.03   300KGXW

Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: .56W/kg; Body-worn .11W/kg

This device contains 900 MHz and 1,800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application jSnhZnNdUwWEEUo7DQCgBg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

UTStarcom Korea Technologies Ltd.
26F, Trust Tower Bldg, 275-7 Yangjae 2-Dong, Seocho-Gu,
Seoul, 137-739
South Korea
  Date of Grant: 08/23/2004

Application Dated: 08/23/2004
 
Attention: Chung-Sung Lee , Director, R&D

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O6Y-UT251
Name of Grantee:  UTStarcom Korea Technologies Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: UT GF251 Handset
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.365 0.03   300KGXW

Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: .56W/kg; Body-worn .11W/kg

This device contains 900 MHz and 1,800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: