FCC ID O8F-715

PDA Phone

by Palm Inc

Grantee Code: O8F   Product Code: 715
Latest application date: 2008-07-14

FCC ID Device Details

FCC IDO8F-715
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeO8F
Product Code715
Applicant BusinessPalm Inc 🇺🇸
Related Domains palm.com ccsemc.com
Equipment ClassPDA Phone
Test FirmSporton International Inc

Hearing Aid Compatibility

Handset MakerPalm
Model NameTreo 800w
Air Interface TechnologiesCDMA, CDMA
Operating Frequency Bands850, 1900
M-RatingM4
M-Rating Certification Date07/14/08
M-Rating ANSI Version2006
T-RatingT4
T-Rating Certification Date07/14/08
T-Rating ANSI Version2006
Wi-Fi InterfaceN

Source: FCC archived Device Manufacturer Summary Report (2009).

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2008-07-14
2402-2480 MHzOriginal Equipment2008-07-14
2412-2462 MHzOriginal Equipment2008-07-14

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2009-01-10PDF 2.9 MB
Antenna LocationInternal Photos2009-01-10PDF 66.6 KB
Internal PhotosInternal Photos2009-01-10PDF 646.2 KB
External PhotosExternal Photos2009-01-10PDF 125.1 KB
Label format and locationID Label/Location Info2008-07-14PDF 503.7 KB
Label placementID Label/Location Info2008-07-14PDF 26.9 KB
Label sample and locationID Label/Location Info2008-07-14PDF 503.7 KB
Location of labelID Label/Location Info2008-07-14PDF 26.9 KB
DTS Test Setup PhotosTest Setup Photos2009-01-10PDF 178.8 KB
HAC T coil test setup photosTest Setup Photos2009-01-10PDF 162.9 KB
Part 22 24 test setup photosTest Setup Photos2009-01-10PDF 161.4 KB
SAR Test Setup PhotosTest Setup Photos2009-01-10PDF 131.1 KB
Test Setup PhotosTest Setup Photos2009-01-10PDF 178.8 KB
BT Test Report 1 of 2Test Report2008-07-14PDF 1.3 MB
BT Test Report 2 of 2Test Report2008-07-14PDF 3.6 MB
DTS Test Report 1 of 3Test Report2008-07-14PDF 3.6 MB
DTS Test Report 2 of 3Test Report2008-07-14PDF 2.8 MB
DTS Test Report 3 of 3Test Report2008-07-14PDF 1.8 MB
HAC T coil test reportTest Report2008-07-14PDF 745.3 KB
HAC Test ReportTest Report2008-07-14PDF 2.9 MB
HAC Test Report Appendix ATest Report2008-07-14PDF 26 KB
Part 22 24 test report 1 of 2Test Report2008-07-14PDF 2.4 MB
Part 22 24 test report 2 of 2Test Report2008-07-14PDF 2.1 MB
SAR Test Report 1 of 2RF Exposure Info2008-07-14PDF 3.3 MB
SAR Test Report 1of 2RF Exposure Info2008-07-14PDF 3.3 MB
SAR Test Report 2 of 2RF Exposure Info2008-07-14PDF 3.2 MB
Agent Authorization LetterCover Letter(s)2008-07-14PDF 29.8 KB
Agent authorization letterCover Letter(s)2008-07-14PDF 29.8 KB
CRN 35020 replyCover Letter(s)2008-07-14PDF 764.6 KB
Request for confidentiality letterCover Letter(s)2008-07-14PDF 23.5 KB
Request for short term and long term confidentiality letterCover Letter(s)2008-07-14PDF 23.5 KB
Request to extend the defer dateCover Letter(s)2008-07-14PDF 20.7 KB

Application Information

Application IDRhr+fKj23XApzBbeM3ZWSw==
Final Action Date2008-07-14
Application PurposeOriginal Equipment
Applicant FRN0007381593
Model-715
Frequency Range824.7-848.31 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionPDA Phone
Responsible PartyHelen Zhao, Sr. Regulatory Compliance Engineer, helen.zhao@palm.com , (408) 617-6508
AgentMike Mike Mike, Compliance Certification Services, mike.kuo@ccsemc.com , 510-771-1105
Technical ContactMike Kuo, Compliance Certification Services, mike.kuo@ccsemc.com , 510-771-1105
Non-Technical ContactMike Kuo, Compliance Certification Services, mike.kuo@ccsemc.com , 510-771-1105
Test FirmKathy Lin, Sporton International Inc, kathy@sporton.com.tw , 886-2-26962468
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/10/2009
Long-Term ConfidentialityYes
Grant DeferralYes
Grant Deferral Date07/14/2008
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to the specific body worn accessories specified in applications under this FCC ID or beltclips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: head: 0.837 W/kg, body: 0.577 W/kg Part 24: head: 1.42 W/kg, body: 0.456 W/kg

Applications

Application IDDatePurpose
Rhr+fKj23XApzBbeM3ZWSw==2008-07-14Original Equipment
OALcn0dXku3IrtyoJ8l3qw==2008-07-14Original Equipment
5k5aYXyMuYKJF4Okwq3V9w==2008-07-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.7-848.31 MHz0.132.5ppm1M25F9W22HBC
1851.25-1908.75 MHz0.442.5ppm1M25F9W24EBC
2402-2480 MHz0.000600015C
2412-2462 MHz0.042000015C

Grants

TCB Grant - Application Rhr+fKj23XApzBbeM3ZWSw==

This application does not exist.

EAS Grant - Application Rhr+fKj23XApzBbeM3ZWSw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Palm Inc
950 West Maude Ave
Sunnyvale, CA 94085
United States
  Date of Grant: 07/14/2008

Application Dated: 02/01/2008
 
Attention: Helen Zhao , Sr. Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O8F-715
Name of Grantee:  Palm Inc
Equipment Class: PCS Licensed Transmitter held to ear
Notes: PDA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.7  -  848.31 0.13 2.5  PM 1M25F9W
BC 24E 1851.25  -  1908.75 0.44 2.5  PM 1M25F9W

Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to the specific body worn accessories specified in applications under this FCC ID or beltclips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: head: 0.837 W/kg, body: 0.577 W/kg Part 24: head: 1.42 W/kg, body: 0.456 W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

TCB Grant - Application OALcn0dXku3IrtyoJ8l3qw==

This application does not exist.

EAS Grant - Application OALcn0dXku3IrtyoJ8l3qw==

Mail To:
Mike Kuo, Vice President
Compliance Certification Services
47173 Benicia Street
Fremont, CA 94538
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Palm Inc
950 West Maude Ave
Sunnyvale, CA 94085
United States
  Date of Grant: 07/14/2008

Application Dated: 02/01/2008
 
Attention: Helen Zhao , Sr. Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O8F-715
Name of Grantee:  Palm Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PDA Pohne
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0006  

Output power is conducted. SAR data for this FCC ID is applicable to demonstrate compliance only for final host product configurations as shown in this filing. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device except as described in filings under this FCC ID. End users must be provided with operating instructions for satisfying RF exposure compliance requirements.



TCB Grant - Application 5k5aYXyMuYKJF4Okwq3V9w==

This application does not exist.

EAS Grant - Application 5k5aYXyMuYKJF4Okwq3V9w==

Mail To:
Mike Kuo, Vice President
Compliance Certification Services
47173 Benicia Street
Fremont, CA 94538
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Palm Inc
950 West Maude Ave
Sunnyvale, CA 94085
United States
  Date of Grant: 07/14/2008

Application Dated: 02/01/2008
 
Attention: Helen Zhao , Sr. Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O8F-715
Name of Grantee:  Palm Inc
Equipment Class: Digital Transmission System
Notes: PDA Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.042  

Output power is conducted. Collocated transmitter operating configurations have been evaluated as described in this filing; other collocation configurations require separate evaluation. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing; body-worn operations are restricted to the specific belt-clips / holsters / accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 15: head: 0.067 W/kg, body: 0.018 W/kg Part 22: head: 0.837 W/kg, body: 0.577 W/kg Part 24: head: 1.420 W/kg, body: 0.456 W/kg



Mail To:
Mike Kuo, Vice President
Compliance Certification Services
47173 Benicia Street
Fremont, CA 94538