FCC ID O9GGMRS522

FRS/GMRS Transceiver

by Trisquare Communications Inc.

Grantee Code: O9G   Product Code: GMRS522
Latest application date: 2002-05-09

FCC ID Device Details

FCC IDO9GGMRS522
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeO9G
Product CodeGMRS522
Applicant BusinessTrisquare Communications Inc. 🇺🇸
Related Domains trisquarecomm.com erols.com
Equipment ClassFRS/GMRS Transceiver
Test FirmCarl T. Jones Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
462.55-462.725 MHzOriginal Equipment2002-05-09

Exhibits

DocumentTypeAvailableFile
User InstructionsUsers Manual2002-05-09PDF 86.6 KB
Circuit Board BackInternal Photos2002-05-09PDF 42.5 KB
Circuit Board TopInternal Photos2002-05-09PDF 38.9 KB
External PhotosExternal Photos2002-05-09PDF 325.2 KB
FCC ID Label and LocationID Label/Location Info2002-05-09PDF 299.1 KB
Block DiagramBlock Diagram2002-05-09PDF 64.2 KB
Schematic DiagramSchematics2002-05-09PDF 220 KB
Operational DescriptionOperational Description2002-05-09PDF 19.5 KB
Test Setup PhotoTest Report2002-05-09PDF 164.6 KB
Test ReportTest Report2002-05-09PDF 1.2 MB
Transmitter Alignment ProcedureParts List/Tune Up Info2002-05-09PDF 33.8 KB

Application Information

Application IDGUUEdIlXl29KsmwPIiQZ1Q==
Final Action Date2002-05-09
Application PurposeOriginal Equipment
Applicant FRN0004315867
ModelGMRS522
Frequency Range462.55-462.725 MHz
Equipment ClassFRF - Part 95 Family Radio Face Held Transmitter
Device DescriptionFRS/GMRS Transceiver
Responsible PartyPhilip Staley, Product Development Manager, pstaley@trisquarecomm.com , (816) 505-3575
AgentRowland Rowland Rowland, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Technical ContactRowland S Johnson, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Non-Technical ContactGeorgia Hall, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Test FirmCarl Jones, Carl T. Jones Corporation, ctjones@ctjc.com , 703-569-7704
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95.

Applications

Application IDDatePurpose
GUUEdIlXl29KsmwPIiQZ1Q==2002-05-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
462.55-462.725 MHz0.410.00025%11k0F3E95A
467.563-467.713 MHz0.450.00025%11k0F3E95B

Grants

TCB Grant - Application GUUEdIlXl29KsmwPIiQZ1Q==

This application does not exist.

EAS Grant - Application GUUEdIlXl29KsmwPIiQZ1Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Trisquare Communications Inc.
1420 Vivion Road Suite 113
Kansas City, MO 64118-4555
United States
  Date of Grant: 05/09/2002

Application Dated: 04/08/2002
 
Attention: Philip Staley , Product Development Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O9GGMRS522
Name of Grantee:  Trisquare Communications Inc.
Equipment Class: Part 95 Family Radio Face Held Transmitter
Notes: FRS/GMRS Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95A 462.55  -  462.725 0.41 0.00025  % 11k0F3E
95B 467.5625  -  467.7125 0.45 0.00025  % 11k0F3E

Power is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95.



Mail To:
Rowland Johnson, President
Hyak Laboratories, Inc.
7011 Calamo St., Suite 107
Springfield, VA 22150