Test FirmEMC Technologies NZ Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.625-914.875 MHzOriginal Equipment2012-05-03

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2012-05-03PDF 977.8 KB
Internal PhotosInternal Photos2012-05-03PDF 383.1 KB
External PhotosExternal Photos2012-05-03PDF 757.5 KB
LabelID Label/Location Info2012-05-03PDF 523 KB
Test Setup PhotosTest Setup Photos2012-05-03PDF 323.5 KB
Test ReportTest Report2012-05-03PDF 1.3 MB
DOC Attestation LetterCover Letter(s)2012-05-03PDF 2.1 MB
Authorization LetterCover Letter(s)2012-05-03PDF 2.1 MB
Confidential LetterCover Letter(s)2012-05-03PDF 2.1 MB
Radiation Hazard AssessmentRF Exposure Info2012-05-03PDF 13.5 KB

Application Information

Application IDF8Q4u+p8kBK9+e3lR1NYgw==
Final Action Date2012-05-03
Application PurposeOriginal Equipment
Applicant FRN0013674825
Model-905UL
Frequency Range902.625-914.875 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionFREQUENCY HOPPING SPREAD SPECTRUM 900 MHz ONE WAY LINK SYSTEM
Responsible PartyHarry Courtice, Engineering Manager, johnw@elpro.com.au , 0061-7-3352-4533
Test FirmAndrew Cutler, EMC Technologies NZ Ltd., auklab@ihug.co.nz , 64-9-360-0862
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is Conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
F8Q4u+p8kBK9+e3lR1NYgw==2012-05-03Original Equipment

Equipment Authorization

FrequencyOutputRules
902.625-914.875 MHz0.7615C
915.125-927.375 MHz0.7615C

Grants

TCB Grant - Application F8Q4u+p8kBK9+e3lR1NYgw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 05/03/2012

Application Dated: 05/03/2012
ELPRO Technologies Pty Ltd
9/12 Billabong Street
StaffordP.O. Box 1544,
Queensland, 4053
Australia
 
Attention: Harry Courtice , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O9P-905UL
Name of Grantee:  ELPRO Technologies Pty Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: FREQUENCY HOPPING SPREAD SPECTRUM 900 MHz ONE WAY LINK SYSTEM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.625  -  914.875 0.76  
15C 915.125  -  927.375 0.76  

Power listed is Conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application F8Q4u+p8kBK9+e3lR1NYgw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ELPRO Technologies Pty Ltd
9/12 Billabong Street StaffordP.O. Box 1544,
Queensland, 4053
Australia
  Date of Grant: 05/03/2012

Application Dated: 05/03/2012
 
Attention: Harry Courtice , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  O9P-905UL
Name of Grantee:  ELPRO Technologies Pty Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: FREQUENCY HOPPING SPREAD SPECTRUM 900 MHz ONE WAY LINK SYSTEM
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.625  -  914.875 0.76  
15C 915.125  -  927.375 0.76  

Power listed is Conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.