FCC ID ODYD4100

Water Meter Interface

by Datamatic, Ltd

Grantee Code: ODY   Product Code: D4100
Latest application date: 2007-10-15

FCC ID Device Details

FCC IDODYD4100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeODY
Product CodeD4100
Applicant BusinessDatamatic, Ltd 🇺🇸
Related Domains datamatic.com
Equipment ClassWater Meter Interface
Test FirmWashington Laboratories, Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.5-927 MHzOriginal Equipment2007-10-15

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2007-10-15PDF 554.6 KB
Internal PhotosInternal Photos2007-10-15PDF 386 KB
External PhotosExternal Photos2007-10-15PDF 159 KB
Label and LocationID Label/Location Info2007-10-15PDF 277.2 KB
Test Setup PhotosTest Setup Photos2007-10-15PDF 75.6 KB
Test ReportTest Report2007-10-15PDF 1.5 MB
Authorization LetterCover Letter(s)2007-10-15PDF 73.5 KB
Confidentiality LetterCover Letter(s)2007-10-15PDF 397.4 KB
Response LetterCover Letter(s)2007-10-15PDF 16.5 KB
RF Exposure MPERF Exposure Info2007-10-15PDF 57.8 KB

Application Information

Application IDJW8aNsToecuh189zBrMGwg==
Final Action Date2007-10-15
Application PurposeOriginal Equipment
Applicant FRN0007039738
ModelD4100
Frequency Range902.5-927 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionWater Meter Interface
Responsible PartyPhilip J. Masters, Chief Financial Officer, pmasters@datamatic.com , 972-234-5000
Technical ContactSteven Koster, Washington Labs, 310-216-1500
Test FirmJohn Repella, Washington Laboratories, Ltd., johnr@wll.com , 301-417-0220
TCB EmailHotline@atcb.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
JW8aNsToecuh189zBrMGwg==2007-10-15Original Equipment

Equipment Authorization

FrequencyOutputRules
902.5-927 MHz0.159000015C

Grants

TCB Grant - Application JW8aNsToecuh189zBrMGwg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 10/15/2007

Application Dated: 10/15/2007
Datamatic, Ltd
3600 K Avenue
Plano, TX 75074
 
Attention: Philip Masters , Chief Financial Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ODYD4100
Name of Grantee:  Datamatic, Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Water Meter Interface
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.5  -  927.0 0.159  

Power Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application JW8aNsToecuh189zBrMGwg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Datamatic, Ltd
3600 K Avenue
Plano, TX 75074
United States
  Date of Grant: 10/15/2007

Application Dated: 10/15/2007
 
Attention: Philip Masters , Chief Financial Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ODYD4100
Name of Grantee:  Datamatic, Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Water Meter Interface
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.5  -  927.0 0.159  

Power Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.