FCC ID OIWBDA800BB50W90
Bi-Directional Amplifier
by Dekolink Wireless Ltd
Grantee Code: OIW Product Code: BDA800BB50W90
Latest application date: 2003-08-11
FCC ID Device Details
| FCC ID | OIWBDA800BB50W90 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OIW |
| Product Code | BDA800BB50W90 |
| Applicant Business | Dekolink Wireless Ltd 🇮🇱 |
| Related Domains | |
| Equipment Class | Bi-Directional Amplifier |
| Test Firm | Nemko Canada Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 835-849 MHz | Original Equipment | 2003-08-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2003-08-11 | PDF 473.8 KB |
| Internal Photos DOWN LINK POWER AMP | Internal Photos | 2003-08-11 | PDF 436.7 KB |
| Internal Photos PRE AMP | Internal Photos | 2003-08-11 | PDF 53.5 KB |
| Internal Photos UP LINK POWER AMP | Internal Photos | 2003-08-11 | PDF 336.3 KB |
| Internal Views | Internal Photos | 2003-08-11 | PDF 861.4 KB |
| External Views | External Photos | 2003-08-11 | PDF 964.7 KB |
| Labek Information | ID Label/Location Info | 2003-08-11 | PDF 493.2 KB |
| Block Diagram | Block Diagram | 2003-08-11 | PDF 612.1 KB |
| Schematics | Schematics | 2003-08-11 | PDF 108.1 KB |
| Operational Desc Downlink specifications | Operational Description | 2003-08-11 | PDF 155.8 KB |
| Operational Desc Uplink specifications | Operational Description | 2003-08-11 | PDF 156.7 KB |
| Operational Description | Operational Description | 2003-08-11 | PDF 241.3 KB |
| Operational Description 2 | Operational Description | 2003-08-11 | PDF 551.8 KB |
| Test Setup Photos | Test Setup Photos | 2003-08-11 | PDF 170.6 KB |
| Test Report | Test Report | 2003-08-11 | PDF 490.8 KB |
| MPE Down Link Indoor Antenna | RF Exposure Info | 2003-08-11 | PDF 75 KB |
| MPE Down Link Outdoor Antenna | RF Exposure Info | 2003-08-11 | PDF 75 KB |
| MPE Uplink | RF Exposure Info | 2003-08-11 | PDF 74.5 KB |
| PART LIST BDA 800BB 50W90 1 | Parts List/Tune Up Info | 2003-08-11 | PDF 166.4 KB |
| RF Exposure Warning | RF Exposure Info | 2003-08-11 | PDF 125.9 KB |
Application Information
| Application ID | IaXo4gSQsG1lWnbzYbBAcg== |
|---|---|
| Final Action Date | 2003-08-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0009032368 |
| Model | BDA800BB50W90 |
| Frequency Range | 835-849 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | Bi-Directional Amplifier |
| Responsible Party | Yaron Moas, yaron@dekolink.com |
| Test Firm | Stuart Beck, Nemko Canada Inc., stuart.beck@nemko.com |
| TCB Email | certification@curtis-straus.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Downlink (indoor) grant conditions – Minimum of 5 antennas are required to be connected to an equal power splitter at the “mobile” antenna terminal of the amplifier to ensure maximum 2W output power on each antenna port. The antennas used for this transmitter(s) are to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi with a minimum of 1 dB cable loss for MPE compliance. Downlink (outdoor) grant conditions – The antenna used for this transmitter(s) is to be fixed-mounted on outdoor permanent structures providing a separation distance of at least 2 meters from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 14.7 dBi with a minimum of 1 dB cable loss for MPE compliance. Uplink (outdoor) grant conditions – The antenna used for this transmitter(s) must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The power outputs listed are the maximum composite total. Frequency stability is dependent on the repeated licensed unit. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| IaXo4gSQsG1lWnbzYbBAcg== | 2003-08-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application IaXo4gSQsG1lWnbzYbBAcg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bureau Veritas Consumer Products Services, Inc. One Distribution Center Circle Suite #1 Littleton, MA 01460 |
Date of Grant: 08/11/2003 Application Dated: 07/31/2003 |
| Dekolink Wireless Ltd |
| 16 Bazel St, Qiryat Arieh |
| Petah Tikva, 497510 Israel |
| Attention: Yaron Moas |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OIWBDA800BB50W90 |
| Name of Grantee: | Dekolink Wireless Ltd |
| Equipment Class: | Amplifier |
| Notes: | Bi-Directional Amplifier |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 835.0 - 849.0 | 1.0 | DXW | ||
| 22 | 835.0 - 849.0 | 1.0 | GXW | ||
| 22 | 835.0 - 849.0 | 1.0 | F9W | ||
| 22 | 880.0 - 894.0 | 10.0 | DXW | ||
| 22 | 880.0 - 894.0 | 10.0 | GXW | ||
| 22 | 880.0 - 894.0 | 10.0 | F9W |
| Downlink (indoor) grant conditions Minimum of 5 antennas are required to be connected to an equal power splitter at the mobile antenna terminal of the amplifier to ensure maximum 2W output power on each antenna port. The antennas used for this transmitter(s) are to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi with a minimum of 1 dB cable loss for MPE compliance. Downlink (outdoor) grant conditions The antenna used for this transmitter(s) is to be fixed-mounted on outdoor permanent structures providing a separation distance of at least 2 meters from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 14.7 dBi with a minimum of 1 dB cable loss for MPE compliance. Uplink (outdoor) grant conditions The antenna used for this transmitter(s) must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The power outputs listed are the maximum composite total. Frequency stability is dependent on the repeated licensed unit. |
EAS Grant - Application IaXo4gSQsG1lWnbzYbBAcg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Dekolink Wireless Ltd 16 Bazel St, Qiryat Arieh Petah Tikva, 497510 Israel |
Date of Grant: 08/11/2003 Application Dated: 07/31/2003 |
| Attention: Yaron Moas |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OIWBDA800BB50W90 |
| Name of Grantee: | Dekolink Wireless Ltd |
| Equipment Class: | Amplifier |
| Notes: | Bi-Directional Amplifier |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 835.0 - 849.0 | 1.0 | DXW | ||
| 22 | 835.0 - 849.0 | 1.0 | GXW | ||
| 22 | 835.0 - 849.0 | 1.0 | F9W | ||
| 22 | 880.0 - 894.0 | 10.0 | DXW | ||
| 22 | 880.0 - 894.0 | 10.0 | GXW | ||
| 22 | 880.0 - 894.0 | 10.0 | F9W |
| Downlink (indoor) grant conditions Minimum of 5 antennas are required to be connected to an equal power splitter at the mobile antenna terminal of the amplifier to ensure maximum 2W output power on each antenna port. The antennas used for this transmitter(s) are to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi with a minimum of 1 dB cable loss for MPE compliance. Downlink (outdoor) grant conditions The antenna used for this transmitter(s) is to be fixed-mounted on outdoor permanent structures providing a separation distance of at least 2 meters from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 14.7 dBi with a minimum of 1 dB cable loss for MPE compliance. Uplink (outdoor) grant conditions The antenna used for this transmitter(s) must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The power outputs listed are the maximum composite total. Frequency stability is dependent on the repeated licensed unit. |
| Mail To: |