Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
758-768 MHzOriginal Equipment2021-01-20
617-652 MHzOriginal Equipment2021-01-20

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2021-07-31PDF 5.7 MB
Internal PhotoInternal Photos2021-01-20PDF 917.4 KB
External PhotoExternal Photos2021-01-20PDF 481.2 KB
LabelID Label/Location Info2021-01-20PDF 391.1 KB
Test Setup PhotoTest Setup Photos2021-01-20PDF 87.1 KB
Test ReportTest Report2021-01-20PDF 5 MB
Attestation letterAttestation Statements2021-01-20PDF 28.5 KB
Applicant Declaration LetterCover Letter(s)2021-01-20PDF 91.5 KB
Authority letterCover Letter(s)2021-01-20PDF 21.2 KB
Confidentiality letterCover Letter(s)2021-01-20PDF 102 KB
MPE reportRF Exposure Info2021-01-20PDF 48.2 KB
Block diagram Metadata onlyBlock DiagramPDF 70.4 KB
Schematic Metadata onlySchematicsPDF 1.5 MB
Operation Description Metadata onlyOperational DescriptionPDF 46.6 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 506.2 KB

Application Information

Application IDf+Mn9f468h4dt/179npYIQ==
Final Action Date2021-01-20
Application PurposeOriginal Equipment
Applicant FRN0017154329
ModelDLRU678
Frequency Range758-768 MHz
Equipment ClassB9B - Part 90 Class B Industrial Booster (non-SMR)
Device DescriptionLow Band dRAU
Responsible PartyJyotin Basrur, Senior Director, Product Line Management, basrurj@corning.com , 817-431-7894
AgentKobe Kobe Kobe, SGS-CSTC Standards Technical Services Co., Ltd, Kobe.Jian@sgs.com , 86-20-82155314
Technical ContactKobe Jian, SGS-CSTC Standards Technical Services Co., Ltd, Kobe.Jian@sgs.com , 86-20-82155314
Non-Technical ContactKobe Jian, SGS-CSTC Standards Technical Services Co., Ltd, Kobe.Jian@sgs.com , 86-20-82155314
Test FirmKobe Jian, SGS-CSTC Standards Technical Services Co., Ltd., kobe.jian@sgs.com , 86-0-20-82155314
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/31/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass B signal booster. In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 50cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 12.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). This device supports 2*2 MIMO.

Applications

Application IDDatePurpose
f+Mn9f468h4dt/179npYIQ==2021-01-20Original Equipment
P4FBtNp/pmCpE590juFApA==2021-01-20Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
617-652 MHz0.21AmpG7W27MO
728-746 MHz0.214AmpG7W27MO
746-757 MHz0.203AmpG7W27MO
758-768 MHz0.2060000AmpG7W90MO, PF
862-869 MHz0.216AmpG7W90SMO
869-894 MHz0.211AmpG7W22HMO

Grants

TCB Grant - Application P4FBtNp/pmCpE590juFApA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 01/20/2021

Application Dated: 01/19/2021
Corning Optical Communication LLC
6 Concord Road
Shrewsbury, MA 01545
 
Attention: Jyotin Basrur , Senior Director, Product Line Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OJFDLRU678
Name of Grantee:  Corning Optical Communication LLC
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Low Band dRAU
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 27 617.0  -  652.0 0.21  Amp G7W
MO 27 728.0  -  746.0 0.214  Amp G7W
MO 27 746.0  -  757.0 0.203  Amp G7W
MO 90S 862.0  -  869.0 0.216  Amp G7W
MO 22H 869.0  -  894.0 0.211  Amp G7W

Class B signal booster. In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 50cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 12.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). This device supports 2*2 MIMO.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application P4FBtNp/pmCpE590juFApA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corning Optical Communication LLC
6 Concord Road
Shrewsbury, MA 01545
United States
  Date of Grant: 01/20/2021

Application Dated: 01/19/2021
 
Attention: Jyotin Basrur , Senior Director, Product Line Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OJFDLRU678
Name of Grantee:  Corning Optical Communication LLC
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Low Band dRAU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 27 617.0  -  652.0 0.21  Amp G7W
MO 27 728.0  -  746.0 0.214  Amp G7W
MO 27 746.0  -  757.0 0.203  Amp G7W
MO 90S 862.0  -  869.0 0.216  Amp G7W
MO 22H 869.0  -  894.0 0.211  Amp G7W

Class B signal booster. In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 50cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 12.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). This device supports 2*2 MIMO.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application f+Mn9f468h4dt/179npYIQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 01/20/2021

Application Dated: 01/20/2021
Corning Optical Communication LLC
6 Concord Road
Shrewsbury, MA 01545
 
Attention: Jyotin Basrur , Senior Director, Product Line Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OJFDLRU678
Name of Grantee:  Corning Optical Communication LLC
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Low Band dRAU
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO PF 90 758.0  -  768.0 0.206  Amp G7W

Class B signal booster. In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 50cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 12.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). This device supports 2*2 MIMO.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
PF: Transmitter approved for Public Safety Broadband

EAS Grant - Application f+Mn9f468h4dt/179npYIQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corning Optical Communication LLC
6 Concord Road
Shrewsbury, MA 01545
United States
  Date of Grant: 01/20/2021

Application Dated: 01/20/2021
 
Attention: Jyotin Basrur , Senior Director, Product Line Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OJFDLRU678
Name of Grantee:  Corning Optical Communication LLC
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Low Band dRAU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO PF 90 758.0  -  768.0 0.206  Amp G7W

Class B signal booster. In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 50cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 12.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). This device supports 2*2 MIMO.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
PF: Transmitter approved for Public Safety Broadband