FCC ID OJFPS-MP-07
Remote Unit
by Corning Optical Communication LLC
Grantee Code: OJF Product Code: PSMP07
Latest application date: 2022-03-15
FCC ID Device Details
| FCC ID | OJFPS-MP-07 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OJF |
| Product Code | PSMP07 |
| Applicant Business | Corning Optical Communication LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Remote Unit |
| Test Firm | Compliance Certification Services (Kunshan) Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-775 MHz | Original Equipment | 2022-03-15 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-03-15 | PDF 2.9 MB |
| Internal photo | Internal Photos | 2022-03-15 | PDF 2 MB |
| External photo | External Photos | 2022-03-15 | PDF 978.3 KB |
| Label | ID Label/Location Info | 2022-03-15 | PDF 457.8 KB |
| Setup photo | Test Setup Photos | 2022-03-15 | PDF 335.3 KB |
| Appendix A Inputoutput power and amplifierbooster gain | Test Report | 2022-03-15 | PDF 140.2 KB |
| Appendix B Conducted Spurious Emissions | Test Report | 2022-03-15 | PDF 1.6 MB |
| Appendix C Out-of-bandout-of-block emissions | Test Report | 2022-03-15 | PDF 674.6 KB |
| Appendix D Radiated Spurious Emissions | Test Report | 2022-03-15 | PDF 292 KB |
| Appendix E Input-versus-output signal comparison | Test Report | 2022-03-15 | PDF 3.3 MB |
| Appendix F Out of Band Rejection. | Test Report | 2022-03-15 | PDF 229.7 KB |
| Appendix G Frequency Stability | Test Report | 2022-03-15 | PDF 166.5 KB |
| Appendix H Noise | Test Report | 2022-03-15 | PDF 562.1 KB |
| Test report | Test Report | 2022-03-15 | PDF 1.1 MB |
| Attestation letter | Attestation Statements | 2022-03-15 | PDF 17.6 KB |
| Applicant_Declaration_Letter | Cover Letter(s) | 2022-03-15 | PDF 112.2 KB |
| Auth letter | Cover Letter(s) | 2022-03-15 | PDF 54 KB |
| Confidentiality_FCC | Cover Letter(s) | 2022-03-15 | PDF 58.7 KB |
| MPE | RF Exposure Info | 2022-03-15 | PDF 284.5 KB |
| Block diagram Metadata only | Block Diagram | PDF 387.6 KB | |
| Schematics Metadata only | Schematics | PDF 3 MB | |
| Operational description Metadata only | Operational Description | PDF 11.9 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 153.9 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 72.7 KB |
Application Information
| Application ID | nUg3g74HAPEo0BJlnx0/9Q== |
|---|---|
| Final Action Date | 2022-03-15 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017154329 |
| Model | PS-MP-07 |
| Frequency Range | 758-775 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | Remote Unit |
| Responsible Party | Jyotin Basrur, Senior Director, Product Line Management, basrurj@corning.com |
| Agent | Parlam Parlam Parlam, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Non-Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Test Firm | Jessica Chen, Compliance Certification Services (Kunshan) Inc., Jessica.chen1@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class B signal booster. Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 36cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| nUg3g74HAPEo0BJlnx0/9Q== | 2022-03-15 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application nUg3g74HAPEo0BJlnx0/9Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 03/15/2022 Application Dated: 03/15/2022 |
| Corning Optical Communication LLC |
| 6 Concord Road |
| Shrewsbury, MA 01545 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-07 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 758.0 - 775.0 | 3.39 | Amp | D1W | |
| 90 | 758.0 - 775.0 | 3.39 | Amp | F3E |
| Class B signal booster. Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 36cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
EAS Grant - Application nUg3g74HAPEo0BJlnx0/9Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Corning Optical Communication LLC 6 Concord Road Shrewsbury, MA 01545 United States |
Date of Grant: 03/15/2022 Application Dated: 03/15/2022 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-07 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 758.0 - 775.0 | 3.39 | Amp | D1W | |
| 90 | 758.0 - 775.0 | 3.39 | Amp | F3E |
| Class B signal booster. Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 36cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
| Mail To: |