FCC ID OJFPS-MP-09
Remote Unit
by Corning Optical Communication LLC
Grantee Code: OJF Product Code: PSMP09
Latest application date: 2022-03-28
FCC ID Device Details
| FCC ID | OJFPS-MP-09 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OJF |
| Product Code | PSMP09 |
| Applicant Business | Corning Optical Communication LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Remote Unit |
| Test Firm | Compliance Certification Services (Kunshan) Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 932-935 MHz | Original Equipment | 2022-03-28 |
| 930-931 MHz | Original Equipment | 2022-03-28 |
| 929-930 MHz | Original Equipment | 2022-03-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-03-28 | PDF 2.7 MB |
| Internal photo | Internal Photos | 2022-03-28 | PDF 2.3 MB |
| External photo | External Photos | 2022-03-28 | PDF 621.8 KB |
| Label | ID Label/Location Info | 2022-03-28 | PDF 433.2 KB |
| Test setup photos | Test Setup Photos | 2022-03-28 | PDF 332.2 KB |
| Appendix A Inputoutput power and amplifierbooster gain | Test Report | 2022-03-28 | PDF 168.3 KB |
| Appendix B Conducted Spurious Emissions | Test Report | 2022-03-28 | PDF 2.6 MB |
| Appendix C Out-of-bandout-of-block emissions | Test Report | 2022-03-28 | PDF 1.6 MB |
| Appendix D Radiated Spurious Emissions | Test Report | 2022-03-28 | PDF 203.4 KB |
| Appendix E Input-versus-output signal comparison | Test Report | 2022-03-28 | PDF 5.9 MB |
| Appendix F Out of Band Rejection. | Test Report | 2022-03-28 | PDF 818.1 KB |
| Appendix G Frequency Stability | Test Report | 2022-03-28 | PDF 223.9 KB |
| Appendix H Noise | Test Report | 2022-03-28 | PDF 447.6 KB |
| Test report | Test Report | 2022-03-28 | PDF 1 MB |
| Attestation letter | Attestation Statements | 2022-03-28 | PDF 43.9 KB |
| Applicant_Declaration_Letter | Cover Letter(s) | 2022-03-28 | PDF 183.9 KB |
| Auth letter | Cover Letter(s) | 2022-03-28 | PDF 132.9 KB |
| Confidentiality_FCC | Cover Letter(s) | 2022-03-28 | PDF 128.1 KB |
| MPE | RF Exposure Info | 2022-03-28 | PDF 291.5 KB |
| Block diagram Metadata only | Block Diagram | PDF 387.6 KB | |
| Schematics Metadata only | Schematics | PDF 3 MB | |
| Operational description Metadata only | Operational Description | PDF 12.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 111.1 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 74.7 KB |
Application Information
| Application ID | t0q0jt//p2rH+BhDm0wIFw== |
|---|---|
| Final Action Date | 2022-03-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017154329 |
| Model | PS-MP-09 |
| Frequency Range | 932-935 MHz |
| Equipment Class | BOS - All other signal boosters other than 20.21/90.219 |
| Device Description | Remote Unit |
| Responsible Party | Jyotin Basrur, Senior Director, Product Line Management, basrurj@corning.com |
| Agent | Parlam Parlam Parlam, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Non-Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Test Firm | Jessica Chen, Compliance Certification Services (Kunshan) Inc., Jessica.chen1@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| t0q0jt//p2rH+BhDm0wIFw== | 2022-03-28 | Original Equipment |
| R07+dI0z9j0fMdDl1Z7sOA== | 2022-03-28 | Original Equipment |
| 6ymVjzciY0IVGDz1RPWkbw== | 2022-03-28 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 929-930 MHz | 3.17 | Amp | D1W | 9 |
| 929-930 MHz | 3.17 | Amp | F3E | 9 |
| 930-931 MHz | 3.21 | Amp | D1W | 24D |
| 930-931 MHz | 3.21 | Amp | F3E | 24D |
| 931-932 MHz | 3.24 | Amp | D1W | 22 |
| 931-932 MHz | 3.24 | Amp | F3E | 22 |
| 932-935 MHz | 3.18 | Amp | D1W | 101 |
| 932-935 MHz | 3.18 | Amp | F3E | 101 |
| 935-940 MHz | 3.26 | Amp | D1W | 9 |
| 935-940 MHz | 3.26 | Amp | F3E | 9 |
| 935-940 MHz | 3.26 | Amp | D1W | 90S |
| 935-940 MHz | 3.26 | Amp | F3E | 90S |
| 940-941 MHz | 3.13 | Amp | D1W | 24D |
| 940-941 MHz | 3.13 | Amp | F3E | 24D |
Grants
TCB Grant - Application t0q0jt//p2rH+BhDm0wIFw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Corning Optical Communication LLC |
| 6 Concord Road |
| Shrewsbury, MA 01545 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Remote Unit |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 932.0 - 935.0 | 3.18 | Amp | D1W | |
| 101 | 932.0 - 935.0 | 3.18 | Amp | F3E |
| Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
EAS Grant - Application t0q0jt//p2rH+BhDm0wIFw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Corning Optical Communication LLC 6 Concord Road Shrewsbury, MA 01545 United States |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Remote Unit |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 932.0 - 935.0 | 3.18 | Amp | D1W | |
| 101 | 932.0 - 935.0 | 3.18 | Amp | F3E |
| Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Corning Optical Communication LLC |
| 6 Concord Road |
| Shrewsbury, MA 01545 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 3.21 | Amp | D1W | |
| 24D | 930.0 - 931.0 | 3.21 | Amp | F3E | |
| 22 | 931.0 - 932.0 | 3.24 | Amp | D1W | |
| 22 | 931.0 - 932.0 | 3.24 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 3.26 | Amp | D1W | |
| 90S | 935.0 - 940.0 | 3.26 | Amp | F3E | |
| 24D | 940.0 - 941.0 | 3.13 | Amp | D1W | |
| 24D | 940.0 - 941.0 | 3.13 | Amp | F3E |
| Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
EAS Grant - Application R07+dI0z9j0fMdDl1Z7sOA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Corning Optical Communication LLC 6 Concord Road Shrewsbury, MA 01545 United States |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 3.21 | Amp | D1W | |
| 24D | 930.0 - 931.0 | 3.21 | Amp | F3E | |
| 22 | 931.0 - 932.0 | 3.24 | Amp | D1W | |
| 22 | 931.0 - 932.0 | 3.24 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 3.26 | Amp | D1W | |
| 90S | 935.0 - 940.0 | 3.26 | Amp | F3E | |
| 24D | 940.0 - 941.0 | 3.13 | Amp | D1W | |
| 24D | 940.0 - 941.0 | 3.13 | Amp | F3E |
| Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Corning Optical Communication LLC |
| 6 Concord Road |
| Shrewsbury, MA 01545 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 929.0 - 930.0 | 3.17 | Amp | D1W | |
| 90 | 929.0 - 930.0 | 3.17 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 3.26 | Amp | D1W | |
| 90 | 935.0 - 940.0 | 3.26 | Amp | F3E |
| Class B signal booster. Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
EAS Grant - Application 6ymVjzciY0IVGDz1RPWkbw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Corning Optical Communication LLC 6 Concord Road Shrewsbury, MA 01545 United States |
Date of Grant: 03/28/2022 Application Dated: 03/28/2022 |
| Attention: Jyotin Basrur , Senior Director, Product Line Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OJFPS-MP-09 |
| Name of Grantee: | Corning Optical Communication LLC |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 929.0 - 930.0 | 3.17 | Amp | D1W | |
| 90 | 929.0 - 930.0 | 3.17 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 3.26 | Amp | D1W | |
| 90 | 935.0 - 940.0 | 3.26 | Amp | F3E |
| Class B signal booster. Power output listed is ERP. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 80cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 0 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirement of 1.1307(b)(3). |
| Mail To: |