TCB Grant - Application Uyv4MI2UGrzjhZwzFXdLcw==
This application does not exist.
EAS Grant - Application Uyv4MI2UGrzjhZwzFXdLcw==
This application currently is not in final status.
TCB Grant - Application Qa4hr3LkQNJEhxvnnSOxJQ==
| TCB |
GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification |
| Issued Under the Authority of the |
| Federal Communications Commission |
| By: |
|
|
ACB, Inc.
6731 Whittier Avenue
Suite C110
McLean, VA 22101
|
Date of Grant: 04/23/2002
Application Dated: 04/23/2002
|
| Ericsson Wireless Communications |
| 6210 Spine Road |
Boulder, CO 80301
|
| |
| Attention: Keith Goshia , Sr. Regulatory Engineering Manager |
|
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
|
|
|
| FCC IDENTIFIER: |
OJYKAG7 |
|
|
| Name of Grantee: |
Ericsson Wireless Communications |
|
|
| Equipment Class: |
PCS Licensed Transmitter |
| Notes: |
PCS Band CDMA Base Station |
| Grant Notes
| FCC Rule Parts
| Frequency Range (MHZ)
| Output Watts
| Frequency Tolerance
| Emission Designator
|
| BC |
24E |
1930.75
-
1989.25
|
20.0
|
2.5
PM
|
1M25F9W
|
| Power output listed is conducted. Equipment qualifies for both Non-building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: |
The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application Qa4hr3LkQNJEhxvnnSOxJQ==
| COPY |
FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554
GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
Ericsson Wireless Communications
6210 Spine Road
Boulder, CO 80301
United States
|
|
Date of Grant: 04/23/2002
Application Dated: 04/23/2002
|
| |
| Attention: Keith Goshia , Sr. Regulatory Engineering Manager |
|
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
|
|
|
| FCC IDENTIFIER: |
OJYKAG7 |
|
|
| Name of Grantee: |
Ericsson Wireless Communications |
|
|
| Equipment Class: |
PCS Licensed Transmitter |
| Notes: |
PCS Band CDMA Base Station |
| Modular Type: |
Does not apply |
| Grant Notes
| FCC Rule Parts
| Frequency Range (MHZ)
| Output Watts
| Frequency Tolerance
| Emission Designator
|
| BC |
24E |
1930.75
-
1989.25
|
20.0
|
2.5
PM
|
1M25F9W
|
| Power output listed is conducted. Equipment qualifies for both Non-building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: |
The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |
|
|
|
|
|
TCB Grant - Application f2s1Q1JyTQRqyvWXI3e7rQ==
| TCB |
GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification |
| Issued Under the Authority of the |
| Federal Communications Commission |
| By: |
|
|
ACB, Inc.
6731 Whittier Avenue
Suite C110
McLean, VA 22101
|
Date of Grant: 02/15/2001
Application Dated: 02/14/2001
|
| Ericsson Wireless Communications |
| 6210 Spine Road |
Boulder, CO 80301
|
| |
| Attention: Keith Goshia , Sr. Regulatory Engineering Manager |
|
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
|
|
|
| FCC IDENTIFIER: |
OJYKAG7 |
|
|
| Name of Grantee: |
Ericsson Wireless Communications |
|
|
| Equipment Class: |
PCS Licensed Transmitter |
| Notes: |
PCS Band CDMA Base Station |
| Grant Notes
| FCC Rule Parts
| Frequency Range (MHZ)
| Output Watts
| Frequency Tolerance
| Emission Designator
|
| BC |
24E |
1930.75
-
1989.25
|
20.0
|
2.5
PM
|
1M25F9W
|
| Power output listed is conducted. Equipment qualifies for both Non- building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building- mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: |
The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application f2s1Q1JyTQRqyvWXI3e7rQ==
| COPY |
FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554
GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
Ericsson Wireless Communications
6210 Spine Road
Boulder, CO 80301
United States
|
|
Date of Grant: 02/15/2001
Application Dated: 02/14/2001
|
| |
| Attention: Keith Goshia , Sr. Regulatory Engineering Manager |
|
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
|
|
|
| FCC IDENTIFIER: |
OJYKAG7 |
|
|
| Name of Grantee: |
Ericsson Wireless Communications |
|
|
| Equipment Class: |
PCS Licensed Transmitter |
| Notes: |
PCS Band CDMA Base Station |
| Modular Type: |
Does not apply |
| Grant Notes
| FCC Rule Parts
| Frequency Range (MHZ)
| Output Watts
| Frequency Tolerance
| Emission Designator
|
| BC |
24E |
1930.75
-
1989.25
|
20.0
|
2.5
PM
|
1M25F9W
|
| Power output listed is conducted. Equipment qualifies for both Non- building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building- mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: |
The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |