FCC ID OMC310900
Wi-Fi Transmitter
by Icon Health and Fitness, Inc.
Grantee Code: OMC Product Code: 310900
Latest application date: 2011-04-27
FCC ID Device Details
| FCC ID | OMC310900 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OMC |
| Product Code | 310900 |
| Applicant Business | Icon Health and Fitness, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Wi-Fi Transmitter |
| Test Firm | Audix Technology (Shenzhen) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2011-04-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2011-04-27 | PDF 496.8 KB |
| Internal Photos | Internal Photos | 2011-04-27 | PDF 512.9 KB |
| External Photos | External Photos | 2011-04-27 | PDF 230.5 KB |
| Label I | ID Label/Location Info | 2011-04-27 | PDF 259.1 KB |
| Label II | ID Label/Location Info | 2011-04-27 | PDF 37 KB |
| Test Setup Photos | Test Setup Photos | 2011-04-27 | PDF 144 KB |
| RF Exposure Report | RF Exposure Info | 2011-04-27 | PDF 56.5 KB |
| Test Report | Test Report | 2011-04-27 | PDF 2.2 MB |
| Authorisation Letter I | Cover Letter(s) | 2011-04-27 | PDF 32 KB |
| Authorisation Letter II | Cover Letter(s) | 2011-04-27 | PDF 31.7 KB |
| Confidentiality Letter | Cover Letter(s) | 2011-04-27 | PDF 59 KB |
Application Information
| Application ID | 4IV2cQE/KKVcmzvwZvVIYw== |
|---|---|
| Final Action Date | 2011-04-27 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0009109950 |
| Model | 310900 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wi-Fi Transmitter |
| Responsible Party | Brent Thompson, Complinace Engineer, brent.thompson@iconfitness.com |
| Test Firm | Smart Tsai, Audix Technology (Shenzhen) Co., Ltd., sindy_song@audix.com.cn |
| TCB Email | Technical@babt.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons to satisfy the requirements of 2.1091 and must not be co-located or operated in conjunction with any other antenna or transmitter not described in this application, except in accordance with FCC multi-transmitter RF exposure procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 4IV2cQE/KKVcmzvwZvVIYw== | 2011-04-27 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.1750000 | 15C |
Grants
TCB Grant - Application 4IV2cQE/KKVcmzvwZvVIYw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 04/27/2011 Application Dated: 04/27/2011 |
| Icon Health and Fitness, Inc. |
| 1500 South 1000 West |
| Logan, UT 84321 |
| Attention: Brent Thompson , Complinace Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OMC310900 |
| Name of Grantee: | Icon Health and Fitness, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wi-Fi Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.175 |
| Power listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons to satisfy the requirements of 2.1091 and must not be co-located or operated in conjunction with any other antenna or transmitter not described in this application, except in accordance with FCC multi-transmitter RF exposure procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 4IV2cQE/KKVcmzvwZvVIYw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Icon Health and Fitness, Inc. 1500 South 1000 West Logan, UT 84321 United States |
Date of Grant: 04/27/2011 Application Dated: 04/27/2011 |
| Attention: Brent Thompson , Complinace Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OMC310900 |
| Name of Grantee: | Icon Health and Fitness, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wi-Fi Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.175 |
| Power listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons to satisfy the requirements of 2.1091 and must not be co-located or operated in conjunction with any other antenna or transmitter not described in this application, except in accordance with FCC multi-transmitter RF exposure procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |