FCC ID OU5-CSONE01

CARESCAPE ONE

by GE Medical Systems Information Technologies Inc.

Grantee Code: OU5   Product Code: CSONE01
Latest application date: 2018-03-21

FCC ID Device Details

FCC IDOU5-CSONE01
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOU5
Product CodeCSONE01
Applicant BusinessGE Medical Systems Information Technologies Inc. 🇺🇸
Related Domains med.ge.com
Equipment ClassCARESCAPE ONE
Test FirmLaird Connectivity, Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2018-03-21
2412-2462 MHzOriginal Equipment2018-03-21

Exhibits

DocumentTypeAvailableFile
2108306-001_FCC_IC_suppl_DRAFT_16Jan18 BlockedUsers Manual2018-09-17PDF 515.8 KB
CS_ONE_UM_DRAFT_26Oct17r BlockedUsers Manual2018-09-17PDF 4.8 MB
Internal Photos V0A BlockedInternal Photos2018-09-17PDF 1.7 MB
External Photos BlockedExternal Photos2018-09-17PDF 709.5 KB
ID Label V0AID Label/Location Info2018-03-21PDF 453.6 KB
W3790-1640 TDS 9-28-2016 - Antenna Datasheet BlockedOperational Description2018-03-21PDF 441.5 KB
Test Setup Photos BlockedTest Setup Photos2018-09-17PDF 661.7 KB
TR317060 A C-2826 V3 FINALr BlockedTest Report2018-03-21PDF 2 MB
TR317060 B C-2826 V4 FINALr BlockedTest Report2018-03-21PDF 3.2 MB
TR317060 C C-2826 V3 FINAL BlockedTest Report2018-03-21PDF 2.2 MB
Software security statment of conformance - GEHC PPDv1 Rev2 signedAttestation Statements2018-03-21PDF 39.9 KB
Confidentiality RequestCover Letter(s)2018-03-21PDF 33.1 KB
FCC Agent Authorization LetterCover Letter(s)2018-03-21PDF 30.8 KB
FCC Request for Confidentiality - GEHC PPDv1 - 0.2Cover Letter(s)2018-03-21PDF 21 KB
RT ResponseCover Letter(s)2018-03-21PDF 137.2 KB
STC AcknowledgmentCover Letter(s)2018-03-21PDF 23.4 KB
TR317060 D C-2826 V3 FINALRF Exposure Info2018-03-21PDF 1.4 MB
Confidential_Block Diagram Metadata onlyBlock DiagramPDF 369.9 KB
Confidential_CARESCAPE ONE_Block Diagram_Theory - 0.6 Metadata onlyOperational DescriptionPDF 705 KB
Confidential_SCHEM_2072636-001RevJ Metadata onlySchematicsPDF 1.8 MB

Application Information

Application IDJpzWTf1LSKrYx4WHQAzc6w==
Final Action Date2018-03-21
Application PurposeOriginal Equipment
Applicant FRN0017065665
ModelCSONE01
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionCARESCAPE ONE
Responsible PartyMike Steinike, Lead System Designer-RF, michael.steinike@med.ge.com , 414-362-2417
AgentThomas Thomas Thomas, Laird Technologies Inc, Tom.Smith@lairdtech.com , 2624214986
Technical ContactMatthew R Pekarske, GE Medical Systems Information Technologies, Matthew.Pekarske@med.ge.com , 414.362.2715
Non-Technical ContactMichael Steinike, GE Medical Systems Information Technologies, Michael.Steinike@med.ge.com , 414.362.2417
Test FirmAdam Alger, Laird Connectivity, Inc, adam.alger@lairdconnect.com , 262 375 3091
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/17/2018
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance.

Applications

Application IDDatePurpose
JpzWTf1LSKrYx4WHQAzc6w==2018-03-21Original Equipment
If1vOxIzpwCU6MfiE0xMWw==2018-03-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.177800015CCC
5180-5240 MHz0.018215E38, CC
5280-5320 MHz0.040715E38, CC
5500-5700 MHz0.022915E38, CC
5745-5825 MHz0.016615E38, CC

Grants

TCB Grant - Application JpzWTf1LSKrYx4WHQAzc6w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/21/2018

Application Dated: 03/20/2018
GE Medical Systems Information Technologies Inc.
8200 West Tower avenue
Milwaukee, WI 53223
 
Attention: Mike Steinike , Lead System Designer-RF

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OU5-CSONE01
Name of Grantee:  GE Medical Systems Information Technologies Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: CARESCAPE ONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5745.0  -  5825.0 0.0166  
38 CC 15E 5180.0  -  5240.0 0.0182  
38 CC 15E 5280.0  -  5320.0 0.0407  
38 CC 15E 5500.0  -  5700.0 0.0229  

Output power is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application JpzWTf1LSKrYx4WHQAzc6w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GE Medical Systems Information Technologies Inc.
8200 West Tower avenue
Milwaukee, WI 53223
United States
  Date of Grant: 03/21/2018

Application Dated: 03/20/2018
 
Attention: Mike Steinike , Lead System Designer-RF

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OU5-CSONE01
Name of Grantee:  GE Medical Systems Information Technologies Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: CARESCAPE ONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5745.0  -  5825.0 0.0166  
38 CC 15E 5180.0  -  5240.0 0.0182  
38 CC 15E 5280.0  -  5320.0 0.0407  
38 CC 15E 5500.0  -  5700.0 0.0229  

Output power is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application If1vOxIzpwCU6MfiE0xMWw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/21/2018

Application Dated: 03/20/2018
GE Medical Systems Information Technologies Inc.
8200 West Tower avenue
Milwaukee, WI 53223
 
Attention: Mike Steinike , Lead System Designer-RF

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OU5-CSONE01
Name of Grantee:  GE Medical Systems Information Technologies Inc.
Equipment Class: Digital Transmission System
Notes: CARESCAPE ONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.1778  

Output power is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application If1vOxIzpwCU6MfiE0xMWw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GE Medical Systems Information Technologies Inc.
8200 West Tower avenue
Milwaukee, WI 53223
United States
  Date of Grant: 03/21/2018

Application Dated: 03/20/2018
 
Attention: Mike Steinike , Lead System Designer-RF

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OU5-CSONE01
Name of Grantee:  GE Medical Systems Information Technologies Inc.
Equipment Class: Digital Transmission System
Notes: CARESCAPE ONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.1778  

Output power is conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. Installers and end-users must be provided with transmitter installation and operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: