FCC ID OUY-FLOW2100-3C

Water Flow Meter

by Kamstrup A/S

Grantee Code: OUY   Product Code: FLOW21003C
Latest application date: 2016-02-29

Device Images

FCC ID Device Details

FCC IDOUY-FLOW2100-3C
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOUY
Product CodeFLOW21003C
Applicant BusinessKamstrup A/S 🇩🇰
Related Domains kamstrup.com
Equipment ClassWater Flow Meter
Test FirmEurofins Product Service GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
912.5-918.5 MHzOriginal Equipment2016-02-29

Exhibits

DocumentTypeAvailableFile
15_flowIQ2100-3c UserManUsers Manual2016-02-29PDF 3.5 MB
09_FlowIQ2100 IntPhoInternal Photos2016-02-29PDF 5.6 MB
09b_flowIQ2100-3c IntPhoInternal Photos2016-02-29PDF 242.9 KB
08_flowIQ2100-3c ExtPhoExternal Photos2016-02-29PDF 106.3 KB
06_flowIQ2100_3c_label LabelSmplID Label/Location Info2016-02-29PDF 113.4 KB
07_flowIQ2100-3c LabelLocID Label/Location Info2016-02-29PDF 84.9 KB
17_flowIQ2100-3c_AntSpecOperational Description2016-02-29PDF 45 KB
10_flowIQ2100-3c TSupTest Setup Photos2016-02-29PDF 68.4 KB
14_flowIQ2100-3c TestRepTest Report2016-02-29PDF 1.8 MB
04_flowIQ2100-3c_AutLet-U_EurofinsAttestation Statements2016-02-29PDF 20.1 KB
05_flowIQ2100-3c_ConReq-U_newCover Letter(s)2016-02-29PDF 20.6 KB
18_flowIQ2100-3c RFExpRF Exposure Info2016-02-29PDF 696.2 KB
12_flowIQ2100-3c_BlkDia Metadata onlyBlock DiagramPDF 44.2 KB
13_flowIQ2100-3c Schem Metadata onlySchematicsPDF 49.9 KB
11_flowIQ2100-3c_OpDes Metadata onlyOperational DescriptionPDF 290.5 KB
16a_flowIQ2100-3c_PartsLst Metadata onlyParts List/Tune Up InfoPDF 26.4 KB
16b_flowIQ2100-3c_PartsLst Metadata onlyParts List/Tune Up InfoPDF 34.3 KB

Application Information

Application IDQe8U6mcIW6fz148yvjqTvQ==
Final Action Date2016-02-29
Application PurposeOriginal Equipment
Applicant FRN0021926498
ModelFLOW2100-3C
Frequency Range912.5-918.5 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWater Flow Meter
Responsible PartyJacob Hansen, Product Manager, jah@kamstrup.com , +4589931000
Technical ContactThomas Stichelbout, Kamstrup A/S, tes@kamstrup.dk , 00458993
Test FirmRobert Kschiwan-Kaspar, Eurofins Product Service GmbH, rkk@eurofins.de , 49-33631-888-000
TCB Emailjoergkusig@eurofins.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance

Applications

Application IDDatePurpose
Qe8U6mcIW6fz148yvjqTvQ==2016-02-29Original Equipment

Equipment Authorization

FrequencyOutputRules
912.5-918.5 MHz0.010000015C

Grants

TCB Grant - Application Qe8U6mcIW6fz148yvjqTvQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 02/29/2016

Application Dated: 02/29/2016
Kamstrup A/S
Industrivej 28
Skanderborg, DK-8660
Denmark
 
Attention: Jacob Hansen , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OUY-FLOW2100-3C
Name of Grantee:  Kamstrup A/S
Equipment Class: Digital Transmission System
Notes: Water Flow Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.5  -  918.5 0.01  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance

EAS Grant - Application Qe8U6mcIW6fz148yvjqTvQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kamstrup A/S
Industrivej 28
Skanderborg, DK-8660
Denmark
  Date of Grant: 02/29/2016

Application Dated: 02/29/2016
 
Attention: Jacob Hansen , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OUY-FLOW2100-3C
Name of Grantee:  Kamstrup A/S
Equipment Class: Digital Transmission System
Notes: Water Flow Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.5  -  918.5 0.01  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance



Mail To: