FCC ID OUY-FLOWX250
flowIQ 2250 or flowIQ 3250
by Kamstrup A/S
Grantee Code: OUY Product Code: FLOWX250
Latest application date: 2020-07-10
FCC ID Device Details
| FCC ID | OUY-FLOWX250 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OUY |
| Product Code | FLOWX250 |
| Applicant Business | Kamstrup A/S 🇩🇰 |
| Related Domains | |
| Equipment Class | flowIQ 2250 or flowIQ 3250 |
| Test Firm | Eurofins Product Service GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450.025-469.988 MHz | Class II permissive change or modification of presently authorized equipment | 2020-07-10 |
| 912.5-918.5 MHz | Class II permissive change or modification of presently authorized equipment | 2020-06-09 |
| 912.5-918.5 MHz | Class II permissive change or modification of presently authorized equipment | 2019-04-05 |
| 450.025-469.988 MHz | Class II permissive change or modification of presently authorized equipment | 2019-04-05 |
| 912.5-918.5 MHz | Original Equipment | 2017-09-18 |
| 450.025-469.988 MHz | Original Equipment | 2017-09-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user man 2250 | Users Manual | 2018-03-13 | PDF 2.6 MB |
| user man 3250 | Users Manual | 2018-03-13 | PDF 2.3 MB |
| int. Photos | Internal Photos | 2020-06-09 | PDF 633 KB |
| Int photos | Internal Photos | 2019-04-05 | PDF 92.1 KB |
| int pho | Internal Photos | 2018-03-13 | PDF 442.6 KB |
| ext. Photos | External Photos | 2020-06-09 | PDF 281.6 KB |
| Ext photos | External Photos | 2019-04-05 | PDF 77.7 KB |
| ext pho | External Photos | 2018-03-13 | PDF 128.7 KB |
| label 2250 | ID Label/Location Info | 2017-09-18 | PDF 22.9 KB |
| label 3250 | ID Label/Location Info | 2017-09-18 | PDF 22.9 KB |
| label loc | ID Label/Location Info | 2017-09-18 | PDF 121.8 KB |
| Test Setup Photos | Test Setup Photos | 2020-06-09 | PDF 311.9 KB |
| Test setup photos | Test Setup Photos | 2019-04-05 | PDF 95.7 KB |
| test setup pho | Test Setup Photos | 2018-03-13 | PDF 165.9 KB |
| Test Report | Test Report | 2020-06-09 | PDF 3.1 MB |
| Test report | Test Report | 2019-04-05 | PDF 1.3 MB |
| rf exp test rpt | Test Report | 2017-09-18 | PDF 768.3 KB |
| test rpt dts | Test Report | 2017-09-18 | PDF 4.4 MB |
| test rpt emc | Test Report | 2017-09-18 | PDF 2.7 MB |
| test rpt part 90 | Test Report | 2017-09-18 | PDF 3.2 MB |
| ant spec helix | Attestation Statements | 2017-09-18 | PDF 94.9 KB |
| ant spec pit | Attestation Statements | 2017-09-18 | PDF 103 KB |
| ant spec wall | Attestation Statements | 2017-09-18 | PDF 431.8 KB |
| aut let | Attestation Statements | 2017-09-18 | PDF 56.8 KB |
| C2PC Letter | Cover Letter(s) | 2020-07-10 | PDF 17.3 KB |
| PoA | Cover Letter(s) | 2020-07-10 | PDF 16.8 KB |
| ConReq | Cover Letter(s) | 2020-06-09 | PDF 28.2 KB |
| Change letter | Cover Letter(s) | 2019-04-05 | PDF 49.1 KB |
| Con req | Cover Letter(s) | 2019-04-05 | PDF 79.5 KB |
| PoA | Cover Letter(s) | 2019-04-05 | PDF 20.9 KB |
| con req (lt) | Cover Letter(s) | 2017-09-18 | PDF 59.4 KB |
| con req (st) | Cover Letter(s) | 2017-09-18 | PDF 51.7 KB |
| rf exp test rpt | RF Exposure Info | 2017-09-18 | PDF 768.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 54.8 KB | |
| blk dia Metadata only | Block Diagram | PDF 105.5 KB | |
| Schematics Metadata only | Schematics | PDF 5.7 MB | |
| schem c1 Metadata only | Schematics | PDF 456.4 KB | |
| schem c2 Metadata only | Schematics | PDF 373.1 KB | |
| schem d1 Metadata only | Schematics | PDF 610.9 KB | |
| Ant Spec Metadata only | Operational Description | PDF 39 KB | |
| Antenna spec Metadata only | Operational Description | PDF 29.4 KB | |
| OpDes Metadata only | Operational Description | PDF 208.6 KB | |
| op des Metadata only | Operational Description | PDF 914.6 KB | |
| Parts list Metadata only | Parts List/Tune Up Info | PDF 906 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 343.1 KB |
Application Information
| Application ID | rcMgWa4jXtuNMmC+3A1XAA== |
|---|---|
| Final Action Date | 2020-07-10 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0021926498 |
| Model | FLOWX250 |
| Frequency Range | 450.025-469.988 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | flowIQ 2250 or flowIQ 3250 |
| Responsible Party | Jacob Hansen, Product Manager, jah@kamstrup.com |
| Technical Contact | Per Madsen, Kamstrup A/S, pem@kamstrup.com |
| Test Firm | Jorg Kusig, Eurofins Product Service GmbH, joergkusig@eurofins.de |
| TCB Email | JoergKusig@eurofins.de |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change: 2 antennas added to listing. Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| rcMgWa4jXtuNMmC+3A1XAA== | 2020-07-10 | Class II permissive change or modification of presently authorized equipment |
| KYSH82/52qX7ouYafQcuQg== | 2020-06-09 | Class II permissive change or modification of presently authorized equipment |
| nAzrfbPHky5F+Ga5lWg4nw== | 2019-04-05 | Class II permissive change or modification of presently authorized equipment |
| QS2nlCJUc70wA9txdf4hLg== | 2019-04-05 | Class II permissive change or modification of presently authorized equipment |
| s1njKNs6R/S6ypvku68nrQ== | 2017-09-18 | Original Equipment |
| bnS+s+BZN/+ycIfNg6U+RQ== | 2017-09-18 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application s1njKNs6R/S6ypvku68nrQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 09/18/2017 Application Dated: 09/18/2017 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Power listed is conducted. |
EAS Grant - Application s1njKNs6R/S6ypvku68nrQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 09/18/2017 Application Dated: 09/18/2017 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Power listed is conducted. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 07/10/2020 Application Dated: 07/10/2020 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 1.0 PM | 9K70F1D |
| Class II Permissive Change: 2 antennas added to listing. Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application rcMgWa4jXtuNMmC+3A1XAA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 07/10/2020 Application Dated: 07/10/2020 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 1.0 PM | 9K70F1D |
| Class II Permissive Change: 2 antennas added to listing. Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 04/05/2019 Application Dated: 04/05/2019 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 0.24 PM | 9K70F1D |
| Class II Permissive Change: Change of antenna switch and oscillator. Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application QS2nlCJUc70wA9txdf4hLg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 04/05/2019 Application Dated: 04/05/2019 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 0.24 PM | 9K70F1D |
| Class II Permissive Change: Change of antenna switch and oscillator. Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 04/05/2019 Application Dated: 04/05/2019 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Class II Permissive Change: Change of antenna switch and oscillator. Power listed is conducted. |
EAS Grant - Application nAzrfbPHky5F+Ga5lWg4nw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 04/05/2019 Application Dated: 04/05/2019 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Class II Permissive Change: Change of antenna switch and oscillator. Power listed is conducted. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 06/09/2020 Application Dated: 06/09/2020 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Class II Permissive Change: 2 antennas added to listing Power listed is conducted. |
EAS Grant - Application KYSH82/52qX7ouYafQcuQg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 06/09/2020 Application Dated: 06/09/2020 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Digital Transmission System |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.5 - 918.5 | 0.018 |
| Class II Permissive Change: 2 antennas added to listing Power listed is conducted. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 09/18/2017 Application Dated: 09/18/2017 |
| Kamstrup A/S |
| Industrivej 28 |
| Skanderborg, DK-8660 Denmark |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 0.24 PM | 9K70F1D |
| Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application bnS+s+BZN/+ycIfNg6U+RQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kamstrup A/S Industrivej 28 Skanderborg, DK-8660 Denmark |
Date of Grant: 09/18/2017 Application Dated: 09/18/2017 |
| Attention: Jacob Hansen , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OUY-FLOWX250 |
| Name of Grantee: | Kamstrup A/S |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | flowIQ 2250 or flowIQ 3250 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.025 - 469.9875 | 0.603 | 0.24 PM | 9K70F1D |
| Output power listed is ERP. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than those contained within this application, End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |