FCC ID OV8-CORPT3

Mobile device for recording and transmitting leak noises

by Seba Dynatronic Mess- und Ortungstechnik GmbH

Grantee Code: OV8   Product Code: CORPT3
Latest application date: 2016-03-09

Device Images

FCC ID Device Details

FCC IDOV8-CORPT3
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOV8
Product CodeCORPT3
Applicant BusinessSeba Dynatronic Mess- und Ortungstechnik GmbH 🇩🇪
Related Domains sebakmt.com
Equipment ClassMobile device for recording and transmitting leak noises
Test FirmCSA Group Bayern GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
468.5 MHzOriginal Equipment2016-03-09

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2016-03-09PDF 4.8 MB
Internal photographsInternal Photos2016-03-09PDF 3.1 MB
External photographsExternal Photos2016-03-09PDF 1.4 MB
Label / label locationID Label/Location Info2016-03-09PDF 124.1 KB
MPE ReportTest Report2016-03-09PDF 536.7 KB
Test reportTest Report2016-03-09PDF 1.5 MB
Authorisation letterCover Letter(s)2016-03-09PDF 34.9 KB
Confidentiality requestCover Letter(s)2016-03-09PDF 87.2 KB
Block diagram Metadata onlyBlock DiagramPDF 31.1 KB
Schematic diagram Metadata onlySchematicsPDF 2.1 MB
Operational description Metadata onlyOperational DescriptionPDF 104.9 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 79.3 KB
Tune-up procedure Metadata onlyParts List/Tune Up InfoPDF 218.7 KB

Application Information

Application IDGU8JK03ElER2DZhsS0lYwg==
Final Action Date2016-03-09
Application PurposeOriginal Equipment
Applicant FRN0021921598
ModelCORPT3
Frequency Range468.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMobile device for recording and transmitting leak noises
Responsible PartyHarald Schuberth, Head of R&D; water products, schuberth.h@sebakmt.com , 49-9544-68-7203
AgentBettina Bettina Bettina, CSA Group Bayern GmbH, Bettina.Stangl@csagroup.org , +4994249481
Technical ContactJosef Knab, CSA Group Bayern GmbH, Josef.Knab@csagroup.org , +4994249481
Test FirmFrank Scharnowski, CSA Group Bayern GmbH, frank.scharnowski@csagroup.org , 49-9424-9481-140
TCB Emailhotline@acbcert.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput Power listed is radiated maximum ERP. The antenna(s) used for this transmitter must be installed to provide separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
GU8JK03ElER2DZhsS0lYwg==2016-03-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
468.5 MHz0.35480.979ppm7K4F3E90.217
469.6 MHz0.42650.363ppm7K9F3E90.217

Grants

TCB Grant - Application GU8JK03ElER2DZhsS0lYwg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/09/2016

Application Dated: 03/07/2016
Seba Dynatronic Mess- und Ortungstechnik GmbH
Dr.-Herbert-lann-Str. 6
Baunach, 96148
Germany
 
Attention: Harald Schuberth , Head of R&D water products

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OV8-CORPT3
Name of Grantee:  Seba Dynatronic Mess- und Ortungstechnik GmbH
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile device for recording and transmitting leak noises
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.217 468.5  -  468.5 0.3548 0.979  PM 7K4F3E
90.217 469.6  -  469.6 0.4265 0.363  PM 7K9F3E

Output Power listed is radiated maximum ERP. The antenna(s) used for this transmitter must be installed to provide separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application GU8JK03ElER2DZhsS0lYwg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Seba Dynatronic Mess- und Ortungstechnik GmbH
Dr.-Herbert-lann-Str. 6 P.O. Box ,
Baunach, 96148
Germany
  Date of Grant: 03/09/2016

Application Dated: 03/07/2016
 
Attention: Harald Schuberth , Head of R&D water products

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OV8-CORPT3
Name of Grantee:  Seba Dynatronic Mess- und Ortungstechnik GmbH
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile device for recording and transmitting leak noises
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.217 468.5  -  468.5 0.3548 0.979  PM 7K4F3E
90.217 469.6  -  469.6 0.4265 0.363  PM 7K9F3E

Output Power listed is radiated maximum ERP. The antenna(s) used for this transmitter must be installed to provide separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: