FCC ID OVF-K5501

Single Band CDMA Cellular Phone with Bluetooth

by Kyocera International, Inc

Grantee Code: OVF   Product Code: K5501
Latest application date: 2010-11-08

FCC ID Device Details

FCC IDOVF-K5501
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOVF
Product CodeK5501
Applicant BusinessKyocera International, Inc 🇺🇸
Related Domains kyocera.com
Equipment ClassSingle Band CDMA Cellular Phone with Bluetooth
Test FirmCompliance Certification Services

Hearing Aid Compatibility

Handset MakerKyocera
Model NameS2100
Air Interface TechnologiesCDMA, CDMA, CDMA
Operating Frequency Bands800, 1700, 1900
M-RatingM4
M-Rating Certification Date01/25/11
M-Rating ANSI Version2007
T-RatingT4
T-Rating Certification Date01/25/11
T-Rating ANSI Version2007
Wi-Fi InterfaceN

Source: FCC archived Device Manufacturer Summary Reports (2011-2013).

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2010-11-08
1851.25-1908.75 MHzOriginal Equipment2010-11-08

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2011-05-07PDF 1.1 MB
Internal PhotosInternal Photos2011-05-07PDF 936 KB
External PhotosExternal Photos2011-05-07PDF 217.3 KB
LabelID Label/Location Info2010-11-08PDF 53.9 KB
Bluetooth Test PhotosTest Setup Photos2011-05-07PDF 372.4 KB
HAC RF Setup PhotosTest Setup Photos2011-05-07PDF 95.9 KB
HAC Tcoil Setup PhotosTest Setup Photos2011-05-07PDF 105.6 KB
Radiated EMC Test PhotosTest Setup Photos2011-05-07PDF 237.4 KB
SAR Setup PhotosTest Setup Photos2011-05-07PDF 52.7 KB
Bluetooth EMC reportTest Report2010-11-08PDF 792.3 KB
Bluetooth RF Conducted ReportTest Report2010-11-08PDF 445.4 KB
HAC PlotsTest Report2010-11-08PDF 120.7 KB
HAC RF ReportTest Report2010-11-08PDF 485.3 KB
HAC RF ValidationTest Report2010-11-08PDF 60.1 KB
HAC Tcoil DataTest Report2010-11-08PDF 126.9 KB
HAC Tcoil ReportTest Report2010-11-08PDF 861.2 KB
RF Conducted ReportTest Report2010-11-08PDF 175.6 KB
RF Radiated ReportTest Report2010-11-08PDF 222.3 KB
Auth Letter 1Cover Letter(s)2010-11-08PDF 25.5 KB
Auth Letter 2Cover Letter(s)2010-11-08PDF 29.8 KB
Confidentiality RequestCover Letter(s)2010-11-08PDF 33.4 KB
Cover LetterCover Letter(s)2010-11-08PDF 22.9 KB
Request for ConfidentialityCover Letter(s)2010-11-08PDF 35.9 KB
TCB Q&ACover Letter(s)2010-11-08PDF 15.9 KB
SAR Diploe CalRF Exposure Info2010-11-08PDF 607.1 KB
SAR Plots BodyRF Exposure Info2010-11-08PDF 73.9 KB
SAR Plots HeadRF Exposure Info2010-11-08PDF 342 KB
SAR Probe CalRF Exposure Info2010-11-08PDF 428.8 KB
SAR ReportRF Exposure Info2010-11-08PDF 397.3 KB
SAR Validation PlotsRF Exposure Info2010-11-08PDF 114.6 KB

Application Information

Application IDuPgeboCOImCyQRw3BQVrZw==
Final Action Date2010-11-08
Application PurposeOriginal Equipment
Applicant FRN0004265831
Model-K5501
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionSingle Band CDMA Cellular Phone with Bluetooth
Responsible PartyDouglas Dunn, Director of Regulatory Engineering, doug.dunn@kyocera.com , 858-882-2117
Test FirmThu Chan, Compliance Certification Services, thu.chan@ccsemc.com , 510-771-1122
TCB Emailcertnotice@ccsemc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date05/07/2011
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC ID. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
uPgeboCOImCyQRw3BQVrZw==2010-11-08Original Equipment
3twNvHWKgR9ruOUCzq8PYA==2010-11-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1851.25-1908.75 MHz1.33000002.5000000000ppm1M25F9W24EHC
2402-2480 MHz0.001400015C

Grants

TCB Grant - Application uPgeboCOImCyQRw3BQVrZw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 11/08/2010

Application Dated: 11/08/2010
Kyocera Communications, Inc
9520 Towne Centre Drive
Suite #200
San Diego, CA 92121
 
Attention: Douglas Dunn , Director of Regulatory Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OVF-K5501
Name of Grantee:  Kyocera Communications, Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Single Band CDMA Cellular Phone with Bluetooth
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  

Output power is conducted. This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC ID. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

EAS Grant - Application uPgeboCOImCyQRw3BQVrZw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kyocera Communications, Inc
9520 Towne Centre Drive Suite #200
San Diego, CA 92121
United States
  Date of Grant: 11/08/2010

Application Dated: 11/08/2010
 
Attention: Douglas Dunn , Director of Regulatory Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OVF-K5501
Name of Grantee:  Kyocera Communications, Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Single Band CDMA Cellular Phone with Bluetooth
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  

Output power is conducted. This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC ID. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.



TCB Grant - Application 3twNvHWKgR9ruOUCzq8PYA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 11/08/2010

Application Dated: 11/08/2010
Kyocera Communications, Inc
9520 Towne Centre Drive
Suite #200
San Diego, CA 92121
 
Attention: Douglas Dunn , Director of Regulatory Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OVF-K5501
Name of Grantee:  Kyocera Communications, Inc
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Single Band CDMA Cellular Phone with Bluetooth
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1851.25  -  1908.75 1.33 2.5  PM 1M25F9W

Output power is EIRP in the 1900 MHz band. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. . The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: 1900 MHz band, Head: 1.52 W/kg, Body-worn: 1.04 W/kg.

HAC Rating: M4/T4 (2007)


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

EAS Grant - Application 3twNvHWKgR9ruOUCzq8PYA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kyocera Communications, Inc
9520 Towne Centre Drive Suite #200
San Diego, CA 92121
United States
  Date of Grant: 11/08/2010

Application Dated: 11/08/2010
 
Attention: Douglas Dunn , Director of Regulatory Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OVF-K5501
Name of Grantee:  Kyocera Communications, Inc
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Single Band CDMA Cellular Phone with Bluetooth
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1851.25  -  1908.75 1.33 2.5  PM 1M25F9W

Output power is EIRP in the 1900 MHz band. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. . The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: 1900 MHz band, Head: 1.52 W/kg, Body-worn: 1.04 W/kg.

HAC Rating: M4/T4 (2007)


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

Mail To: