FCC ID OWDTR-0046-E

P5400 UHF-H Portable Radio

by HARRIS CORPORATION

Grantee Code: OWD   Product Code: TR0046E
Latest application date: 2010-07-29

FCC ID Device Details

FCC IDOWDTR-0046-E
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOWD
Product CodeTR0046E
Applicant BusinessHARRIS CORPORATION 🇺🇸
Related Domains harris.com
Equipment ClassP5400 UHF-H Portable Radio

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
440-512 MHzClass II permissive change or modification of presently authorized equipment2010-07-29
440-512 MHzClass II permissive change or modification of presently authorized equipment2010-03-05
440-512 MHzOriginal Equipment2007-10-01

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2007-10-01PDF 2.2 MB
Internal photosInternal Photos2007-10-01PDF 848.5 KB
External photosExternal Photos2007-10-01PDF 381 KB
FCC ID labelID Label/Location Info2007-10-01PDF 165.3 KB
Setup photosTest Setup Photos2010-07-29PDF 155.9 KB
set up photosTest Setup Photos2007-10-01PDF 1.2 MB
Test reortTest Report2010-07-29PDF 259.2 KB
Test report REVTest Report2007-10-01PDF 943.8 KB
Cover letterCover Letter(s)2010-07-29PDF 9.2 KB
POACover Letter(s)2010-07-29PDF 61.4 KB
Reason for PCCover Letter(s)2010-07-29PDF 59.1 KB
Cover letterCover Letter(s)2010-03-05PDF 35.3 KB
ATCB commentsCover Letter(s)2007-10-01PDF 53.3 KB
POACover Letter(s)2007-10-01PDF 69.3 KB
Request for ConfidentialityCover Letter(s)2007-10-01PDF 70.8 KB
Response to ATCBCover Letter(s)2007-10-01PDF 27.6 KB
SAR 1RF Exposure Info2007-10-01PDF 789.6 KB
SAR 2RF Exposure Info2007-10-01PDF 1.7 MB
SAR 3RF Exposure Info2007-10-01PDF 1.1 MB
SAR 4RF Exposure Info2007-10-01PDF 1.7 MB
SAR 5RF Exposure Info2007-10-01PDF 601.5 KB
SAR 6RF Exposure Info2007-10-01PDF 1.1 MB

Application Information

Application ID2bNNLgWopnV57bBqKnTf3w==
Final Action Date2010-07-29
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0004945812
ModelTR-0046-E
Frequency Range440-512 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionP5400 UHF-H Portable Radio
Responsible PartyWilliam Pertner, Regulatory Manager, william.pertner@Harris.com , 434-455-9295
TCB Emailhotline@americantcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is manufacturer's rated power. Measured power is 4.3 W. The power is continuously variable from 0.5W to 4.0W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the Harris Corporation listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg. This PC2 adds emissions designator 17K1F1D and 17K1F1E.

Applications

Application IDDatePurpose
2bNNLgWopnV57bBqKnTf3w==2010-07-29Class II permissive change or modification of presently authorized equipment
wIQloWluw2eEeoJ6w2Mkuw==2010-03-05Class II permissive change or modification of presently authorized equipment
XDQYgI6e6RepWzogIvXbuQ==2007-10-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
440-512 MHz40.48ppm14K2F1E9
440-512 MHz40.48ppm16K0F3E9
440-512 MHz40.48ppm17K1F1D9
440-512 MHz40.48ppm17K1F1E9
440-512 MHz40.48ppm11K0F3E9
440-512 MHz40.48ppm7K10F1D9
440-512 MHz40.48ppm7K10F1E9
440-512 MHz40.48ppm8K40F1D9
440-512 MHz448ppm8K40F1E9
440-512 MHz40.48ppm8K40F1E9
440-512 MHz40.48ppm10K3F1D9
440-512 MHz40.48ppm10K3F1E9
440-512 MHz40.48ppm14K2F1D9

Grants

TCB Grant - Application XDQYgI6e6RepWzogIvXbuQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 10/01/2007

Application Dated: 09/28/2007
HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 0.48  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E

Power listed is manufacturer's rated power. Measured power is 4.3 W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the M/A-COM, Inc. listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg.

EAS Grant - Application XDQYgI6e6RepWzogIvXbuQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
United States
  Date of Grant: 10/01/2007

Application Dated: 09/28/2007
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 0.48  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E

Power listed is manufacturer's rated power. Measured power is 4.3 W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the M/A-COM, Inc. listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg.



TCB Grant - Application wIQloWluw2eEeoJ6w2Mkuw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/05/2010

Application Dated: 03/04/2010
HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 48.0  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E

Power listed is manufacturer's rated power. Measured power is 4.3 W. The power is continuously variable from 0.5W to 4.0W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the Harris Corporation listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg.

EAS Grant - Application wIQloWluw2eEeoJ6w2Mkuw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
United States
  Date of Grant: 03/05/2010

Application Dated: 03/04/2010
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 48.0  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E

Power listed is manufacturer's rated power. Measured power is 4.3 W. The power is continuously variable from 0.5W to 4.0W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the Harris Corporation listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg.



TCB Grant - Application 2bNNLgWopnV57bBqKnTf3w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/29/2010

Application Dated: 07/28/2010
HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 0.48  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 17K1F1D
90 440.0  -  512.0 4.0 0.48  PM 17K1F1E

Power listed is manufacturer's rated power. Measured power is 4.3 W. The power is continuously variable from 0.5W to 4.0W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the Harris Corporation listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg. This PC2 adds emissions designator 17K1F1D and 17K1F1E.

EAS Grant - Application 2bNNLgWopnV57bBqKnTf3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

HARRIS CORPORATION
221 Jefferson Ridge Parkway
Lynchburg, VA 24501
United States
  Date of Grant: 07/29/2010

Application Dated: 07/28/2010
 
Attention: William Pertner , Regulatory Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWDTR-0046-E
Name of Grantee:  HARRIS CORPORATION
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: P5400 UHF-H Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 440.0  -  512.0 4.0 0.48  PM 16K0F3E
90 440.0  -  512.0 4.0 0.48  PM 11K0F3E
90 440.0  -  512.0 4.0 0.48  PM 7K10F1D
90 440.0  -  512.0 4.0 0.48  PM 7K10F1E
90 440.0  -  512.0 4.0 0.48  PM 8K40F1D
90 440.0  -  512.0 4.0 0.48  PM 8K40F1E
90 440.0  -  512.0 4.0 0.48  PM 10K3F1D
90 440.0  -  512.0 4.0 0.48  PM 10K3F1E
90 440.0  -  512.0 4.0 0.48  PM 14K2F1D
90 440.0  -  512.0 4.0 0.48  PM 14K2F1E
90 440.0  -  512.0 4.0 0.48  PM 17K1F1D
90 440.0  -  512.0 4.0 0.48  PM 17K1F1E

Power listed is manufacturer's rated power. Measured power is 4.3 W. The power is continuously variable from 0.5W to 4.0W. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the Harris Corporation listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This transmitter may operate only with antennas as described in this filing. SAR was evaluated for body worn and held-to-face operating modes. Maximum SAR values reported are: Body 4.82 w/kg. This PC2 adds emissions designator 17K1F1D and 17K1F1E.