FCC ID OWDTR0007-E
Portable Trunking Radio
by HARRIS CORPORATION
Grantee Code: OWD Product Code: TR0007E
Latest application date: 2001-02-26
FCC ID Device Details
| FCC ID | OWDTR0007-E |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | OWD |
| Product Code | TR0007E |
| Applicant Business | HARRIS CORPORATION 🇺🇸 |
| Related Domains | |
| Equipment Class | Portable Trunking Radio |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 896-901 MHz | Original Equipment | 2001-02-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Operators manual with modifications | Users Manual | 2001-02-26 | PDF 497.9 KB |
| users manual | Users Manual | 2001-02-26 | PDF 498.6 KB |
| Internal Photos | Internal Photos | 2001-02-26 | PDF 205.6 KB |
| External Photos | External Photos | 2001-02-26 | PDF 139.5 KB |
| ID Lable | ID Label/Location Info | 2001-02-26 | PDF 33.4 KB |
| Schematics | Schematics | 2001-02-26 | PDF 3 MB |
| Operational description | Operational Description | 2001-02-26 | PDF 39.6 KB |
| techical info | Operational Description | 2001-02-26 | PDF 45.5 KB |
| ERP measurements | Test Report | 2001-02-26 | PDF 6.3 KB |
| Test Report | Test Report | 2001-02-26 | PDF 733.7 KB |
| Attestation Statement | Attestation Statements | 2001-02-26 | PDF 9.9 KB |
| Cover Letter | Cover Letter(s) | 2001-02-26 | PDF 17.4 KB |
| Aprel answers | RF Exposure Info | 2001-02-26 | PDF 39.6 KB |
| Aprel answers to questions | RF Exposure Info | 2001-02-26 | PDF 139.6 KB |
| ComNet answers to remaining questions | RF Exposure Info | 2001-02-26 | PDF 17.1 KB |
| Cover sheet | RF Exposure Info | 2001-02-26 | PDF 27.4 KB |
| Part List | Parts List/Tune Up Info | 2001-02-26 | PDF 58.5 KB |
| RF Exposer | RF Exposure Info | 2001-02-26 | PDF 1.7 MB |
| RF Exposure (SAR report) | RF Exposure Info | 2001-02-26 | PDF 716.8 KB |
| RF Exposure label | RF Exposure Info | 2001-02-26 | PDF 3.9 KB |
| SAR label | RF Exposure Info | 2001-02-26 | PDF 7.2 KB |
Application Information
| Application ID | O/CqDrGx1MTstRUYituM/A== |
|---|---|
| Final Action Date | 2001-02-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004945812 |
| Model | TR0007-E |
| Frequency Range | 896-901 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | Portable Trunking Radio |
| Responsible Party | Thomas Camper, Jr., Regulatory Manager, tcamper@harris.com |
| Technical Contact | Bryan L McWatters, Ericsson Inc., bryan_mcwatters@ieee.org |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is conducted. This transmitter may operate with a quarter-wave or a half-wave antenna, as tested in this filing for Push-to-Talk and body-worn operating configurations, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. It must be used for work related operations, not exceeding a maximum transmitting duty factor of 50% for satisfying RF exposure compliance. Qualifying end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. Body-worn SAR compliance is limited to the specific belt-clip/belt-loop and speaker/microphone configurations tested for this filing. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 100% duty factor are - Head: 6.4 W/kg; Body-worn: 5.67 W/kg; Hand: 10.83 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| O/CqDrGx1MTstRUYituM/A== | 2001-02-26 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application O/CqDrGx1MTstRUYituM/A==
This application does not exist.
EAS Grant - Application O/CqDrGx1MTstRUYituM/A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
HARRIS CORPORATION 221 Jefferson Ridge Parkway Lynchburg, VA 24501 United States |
Date of Grant: 02/26/2001 Application Dated: 10/19/2000 |
| Attention: Thomas Camper, Jr. , Regulatory Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | OWDTR0007-E |
| Name of Grantee: | HARRIS CORPORATION |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Portable Trunking Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 896.0 - 901.0 | 1.7 | 1.5 PM | 10K0F3E | |
| 90 | 896.0 - 901.0 | 1.7 | 1.5 PM | 8K8F1D | |
| 90 | 896.0 - 901.0 | 1.7 | 1.5 PM | 8K8F1E | |
| 90 | 935.0 - 940.0 | 1.7 | 1.5 PM | 10K0F3E | |
| 90 | 935.0 - 940.0 | 1.7 | 1.5 PM | 8K8F1D | |
| 90 | 935.0 - 940.0 | 1.7 | 1.5 PM | 8K8F1E |
| Output is conducted. This transmitter may operate with a quarter-wave or a half-wave antenna, as tested in this filing for Push-to-Talk and body-worn operating configurations, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. It must be used for work related operations, not exceeding a maximum transmitting duty factor of 50% for satisfying RF exposure compliance. Qualifying end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. Body-worn SAR compliance is limited to the specific belt-clip/belt-loop and speaker/microphone configurations tested for this filing. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 100% duty factor are - Head: 6.4 W/kg; Body-worn: 5.67 W/kg; Hand: 10.83 W/kg. |