FCC ID OWS-940

IMU WATER METER

by Itron, Inc

Grantee Code: OWS   Product Code: 940
Latest application date: 2005-07-12

FCC ID Device Details

FCC IDOWS-940
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeOWS
Product Code940
Applicant BusinessItron, Inc 🇺🇸
Related Domains itron.com
Equipment ClassIMU WATER METER
Test FirmITC Engineering Services, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903.68-926.208 MHzOriginal Equipment2005-07-12

Exhibits

DocumentTypeAvailableFile
INTERNAL PHOTOSInternal Photos2005-07-12PDF 294.1 KB
EXTERNAL PHOTOSExternal Photos2005-07-12PDF 287.9 KB
ID LABEL LOCATIONID Label/Location Info2005-07-12PDF 112.4 KB
SCHEMATICS 2 OF 2 Metadata onlySchematics2005-07-12PDF 4.7 KB
TEST SETUP PHOTOSTest Setup Photos2005-07-12PDF 566.3 KB
TEST REPORTTest Report2005-07-12PDF 1.8 MB
COFIDENTIALITY LETTERCover Letter(s)2005-07-12PDF 16.7 KB
USERS MANUAL Metadata onlyUsers ManualPDF 357.8 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 55.4 KB
SCHEMATICS 1 OF 2 Metadata onlySchematicsPDF 90.6 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 163.9 KB

Application Information

Application IDgbYpo04AnPQ0mv1aM24zaA==
Final Action Date2005-07-12
Application PurposeOriginal Equipment
Applicant FRN0017775842
Model940
Frequency Range903.68-926.208 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionIMU WATER METER
Responsible PartyAsim Tirmizi, Regulatory Engineering Manager, Asim.Tirmizi@itron.com , 669-770-4000
Test FirmMichael Gbadebo, ITC Engineering Services, Inc., itcemc@itcemc.com , 9258622944
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is Conducted. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
gbYpo04AnPQ0mv1aM24zaA==2005-07-12Original Equipment

Equipment Authorization

FrequencyOutputRules
903.68-926.208 MHz0.070000015C

Grants

TCB Grant - Application gbYpo04AnPQ0mv1aM24zaA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 07/12/2005

Application Dated: 07/12/2005
Itron, Inc
230 W. Tasman Dr.
San Jose, CA 95134
 
Attention: Asim Tirmizi , Regulatory Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWS-940
Name of Grantee:  Itron, Inc
Equipment Class: Digital Transmission System
Notes: IMU WATER METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.68  -  926.208 0.07  

Power listed is Conducted. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application gbYpo04AnPQ0mv1aM24zaA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc
230 W. Tasman Dr.
San Jose, CA 95134
United States
  Date of Grant: 07/12/2005

Application Dated: 07/12/2005
 
Attention: Asim Tirmizi , Regulatory Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  OWS-940
Name of Grantee:  Itron, Inc
Equipment Class: Digital Transmission System
Notes: IMU WATER METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.68  -  926.208 0.07  

Power listed is Conducted. This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.