FCC ID P27GPONHGU
GPON HGU
by Sercomm Corporation
Grantee Code: P27 Product Code: GPONHGU
Latest application date: 2023-03-07
FCC ID Device Details
| FCC ID | P27GPONHGU |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | P27 |
| Product Code | GPONHGU |
| Applicant Business | Sercomm Corporation 🇹🇼 |
| Related Domains | |
| Equipment Class | GPON HGU |
| Test Firm | MRT Technology (Suzhou) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2023-03-07 |
| 2412-2462 MHz | Original Equipment | 2023-03-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| FG6222R_User Manual | Users Manual | 2023-03-07 | PDF 3.8 MB |
| Internal Photos | Internal Photos | 2023-03-07 | PDF 1.1 MB |
| External Photos | External Photos | 2023-03-07 | PDF 838.9 KB |
| Label Location | ID Label/Location Info | 2023-03-07 | PDF 1.6 MB |
| Test Setup Photos | Test Setup Photos | 2023-03-07 | PDF 462.4 KB |
| Test Setup Photos | Test Report | 2023-03-07 | PDF 462.4 KB |
| FCC DFS Test Report | Test Report | 2023-03-07 | PDF 4.2 MB |
| FCC DTS Test Report_Part1 | Test Report | 2023-03-07 | PDF 5.3 MB |
| FCC DTS Test Report_Part2 | Test Report | 2023-03-07 | PDF 5.1 MB |
| FCC DTS Test Report_Part3 | Test Report | 2023-03-07 | PDF 4.9 MB |
| FCC NII Test Report_Part1 | Test Report | 2023-03-07 | PDF 5.5 MB |
| FCC NII Test Report_Part2 | Test Report | 2023-03-07 | PDF 4.9 MB |
| FCC NII Test Report_Part3 | Test Report | 2023-03-07 | PDF 5.1 MB |
| FCC NII Test Report_Part4 | Test Report | 2023-03-07 | PDF 5.4 MB |
| FCC NII Test Report_Part5 | Test Report | 2023-03-07 | PDF 5.2 MB |
| FCC NII Test Report_Part6 | Test Report | 2023-03-07 | PDF 5.2 MB |
| FCC NII Test Report_Part7 | Test Report | 2023-03-07 | PDF 5.1 MB |
| FCC NII Test Report_Part8 | Test Report | 2023-03-07 | PDF 5.5 MB |
| FCC NII Test Report_Part9 | Test Report | 2023-03-07 | PDF 5.4 MB |
| FG6222R_Antenna Test Report | Test Report | 2023-03-07 | PDF 1.9 MB |
| FG6222R_Attestation Statements_20230215 | Attestation Statements | 2023-03-07 | PDF 230.6 KB |
| FG6222R_FCC Attestation Letter_20230207 | Cover Letter(s) | 2023-03-07 | PDF 189.5 KB |
| FG6222R_U.S. local Agent Letter | Attestation Statements | 2023-03-07 | PDF 48.1 KB |
| FG6222R_DoC Letter_20230207 | Cover Letter(s) | 2023-03-07 | PDF 155.1 KB |
| FG6222R_FCC Confidentiality Letter_20230207 | Cover Letter(s) | 2023-03-07 | PDF 174 KB |
| FG6222R_FCC Declaration of Authorization_20230207 | Cover Letter(s) | 2023-03-07 | PDF 172.9 KB |
| FG6222R_Model Difference Declaration letter_20230215 | Cover Letter(s) | 2023-03-07 | PDF 151.6 KB |
| FG6222R_U.S. local Agent Letter Metadata only | Cover Letter(s) | 2023-03-07 | PDF 48.1 KB |
| FCC Exposure Report | RF Exposure Info | 2023-03-07 | PDF 439.5 KB |
| Confidential_Block Diagram Metadata only | Block Diagram | PDF 128.9 KB | |
| Confidential_Schematic Metadata only | Schematics | PDF 1.3 MB | |
| Confidential_FG6222R_Operation Description_20230215 Metadata only | Operational Description | PDF 395.4 KB | |
| FG6222R_FCC SDR Security Description_20230207 Metadata only | SDR Software/Security Inf | PDF 185.2 KB | |
| FG6222R_SDR_Letter_20230207 Metadata only | SDR Software/Security Inf | PDF 152.4 KB | |
| FG6222R_Software Security Requirements Cover Letter_20230215 Metadata only | SDR Software/Security Inf | PDF 198.1 KB |
Application Information
| Application ID | smodbWY76rigC8299sQF6A== |
|---|---|
| Final Action Date | 2023-03-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0015548027 |
| Model | GPONHGU |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | GPON HGU |
| Responsible Party | Nick Wu, Engineer, Nick_wu@SERCOMM.COM |
| Agent | Marlin Marlin Marlin, MRT Technology (Suzhou) Co., Ltd, marlinchen@mrt-cert.com |
| Technical Contact | Robin Wu, MRT Technology (Suzhou) Co., Ltd, robinwu@mrt-cert.com |
| Non-Technical Contact | Robin Wu, MRT Technology (Suzhou) Co., Ltd, robinwu@mrt-cert.com |
| Test Firm | Mr. Marlin Chen, MRT Technology (Suzhou) Co., Ltd., marlinchen@mrt-cert.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | Yes |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Power Output listed is conducted. Device is an 802.11a/n/ac/ax device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing.The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has HT/VHT/HE 20 MHz, HT/VHT/HE 40 MHz and VHT/HE 80 MHz bandwidth modes in 5GHz WLAN transmitter and it contains 2.4GHz WLAN transmitter. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| smodbWY76rigC8299sQF6A== | 2023-03-07 | Original Equipment |
| mDGcvD96pos6WJYsyOePJg== | 2023-03-07 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application smodbWY76rigC8299sQF6A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 03/07/2023 Application Dated: 02/08/2023 |
| Sercomm Corporation |
| 8F, No. 3-1, YuanQu St, NanKang |
| Taipei, 115 Taiwan |
| Attention: Nick Wu , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P27GPONHGU |
| Name of Grantee: | Sercomm Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | GPON HGU |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.4295 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.2388 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.2443 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.3846 |
| Power Output listed is conducted. Device is an 802.11a/n/ac/ax device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing.The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has HT/VHT/HE 20 MHz, HT/VHT/HE 40 MHz and VHT/HE 80 MHz bandwidth modes in 5GHz WLAN transmitter and it contains 2.4GHz WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application smodbWY76rigC8299sQF6A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sercomm Corporation 8F, No. 3-1, YuanQu St, NanKang Taipei, 115 Taiwan |
Date of Grant: 03/07/2023 Application Dated: 02/08/2023 |
| Attention: Nick Wu , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P27GPONHGU |
| Name of Grantee: | Sercomm Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | GPON HGU |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.4295 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.2388 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.2443 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.3846 |
| Power Output listed is conducted. Device is an 802.11a/n/ac/ax device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing.The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has HT/VHT/HE 20 MHz, HT/VHT/HE 40 MHz and VHT/HE 80 MHz bandwidth modes in 5GHz WLAN transmitter and it contains 2.4GHz WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 03/07/2023 Application Dated: 02/08/2023 |
| Sercomm Corporation |
| 8F, No. 3-1, YuanQu St, NanKang |
| Taipei, 115 Taiwan |
| Attention: Nick Wu , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P27GPONHGU |
| Name of Grantee: | Sercomm Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | GPON HGU |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.2455 |
| Output power listed is conducted. Device is an 802.11 b/g/n/ax device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes in 2.4GHz WLAN transmitter and it contains 5GHz WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application mDGcvD96pos6WJYsyOePJg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sercomm Corporation 8F, No. 3-1, YuanQu St, NanKang Taipei, 115 Taiwan |
Date of Grant: 03/07/2023 Application Dated: 02/08/2023 |
| Attention: Nick Wu , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P27GPONHGU |
| Name of Grantee: | Sercomm Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | GPON HGU |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.2455 |
| Output power listed is conducted. Device is an 802.11 b/g/n/ax device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes in 2.4GHz WLAN transmitter and it contains 5GHz WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |