FCC ID P3TDH7
BI-DIRECTIONAL AMPLIFIER
by Fiplex Communications Inc
Grantee Code: P3T Product Code: DH7
Latest application date: 2017-04-28
FCC ID Device Details
| FCC ID | P3TDH7 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | P3T |
| Product Code | DH7 |
| Applicant Business | Fiplex Communications Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | BI-DIRECTIONAL AMPLIFIER |
| Test Firm | Nemko Canada Inc. (Ottawa) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 763-775 MHz | Original Equipment | 2017-04-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2017-04-28 | PDF 1.8 MB |
| user manual Metadata only | Test Report | 2017-04-28 | PDF 1.8 MB |
| external photos | External Photos | 2017-04-28 | PDF 416.1 KB |
| label and location | ID Label/Location Info | 2017-04-28 | PDF 540.9 KB |
| test report | Test Report | 2017-04-28 | PDF 2.4 MB |
| agent letter | Cover Letter(s) | 2017-04-28 | PDF 12.6 KB |
| confidential letter | Cover Letter(s) | 2017-04-28 | PDF 900.7 KB |
| signal booster letter | Cover Letter(s) | 2017-04-28 | PDF 183.5 KB |
| MPE | RF Exposure Info | 2017-04-28 | PDF 231.3 KB |
| tune up procedure | Parts List/Tune Up Info | 2017-04-28 | PDF 10.3 KB |
| internal photos Metadata only | Internal Photos | PDF 2.2 MB | |
| block diagram Metadata only | Block Diagram | PDF 187.1 KB | |
| schematics Metadata only | Schematics | PDF 2.2 MB | |
| operational description Metadata only | Operational Description | PDF 190.2 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 492.7 KB |
Application Information
| Application ID | +U4tRnP19jsUCuvwFjLwCw== |
|---|---|
| Final Action Date | 2017-04-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005657499 |
| Model | DH7 |
| Frequency Range | 763-775 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | BI-DIRECTIONAL AMPLIFIER |
| Responsible Party | Ricardo de Goycoechea, General Manager, fiplex@signalgrp.com |
| Agent | Michelle Michelle Michelle, Nemko USA, Inc., michelle.furrow@nemko.com |
| Test Firm | Charles Neal, Nemko Canada Inc. (Ottawa), charles.neal@nemko.com |
| TCB Email | stuart.beck@nemko.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is the composite for multi-channel operation. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| +U4tRnP19jsUCuvwFjLwCw== | 2017-04-28 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 763-775 MHz | 5 | Amp | F1D | 9 | EF |
| 763-775 MHz | 5 | Amp | D1E | 9 | EF |
| 763-775 MHz | 5 | Amp | D1D | 9 | EF |
| 763-775 MHz | 5 | Amp | FXE | 9 | EF |
| 763-775 MHz | 5 | Amp | FXD | 9 | EF |
| 763-775 MHz | 5 | Amp | F3E | 9 | EF |
| 793-805 MHz | 0.25 | Amp | D1E | 9 | EF |
| 793-805 MHz | 0.25 | Amp | D1D | 9 | EF |
| 793-805 MHz | 0.25 | Amp | FXE | 9 | EF |
| 793-805 MHz | 0.25 | Amp | FXD | 9 | EF |
| 793-805 MHz | 0.25 | Amp | F3E | 9 | EF |
| 793-805 MHz | 0.25 | Amp | F1E | 9 | EF |
| 793-805 MHz | 0.25 | Amp | F1D | 9 | EF |
Grants
TCB Grant - Application +U4tRnP19jsUCuvwFjLwCw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 04/28/2017 Application Dated: 04/23/2017 |
| Fiplex Communications Inc |
| 2101 NW 79th Ave. |
| Miami, FL 33122 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TDH7 |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | BI-DIRECTIONAL AMPLIFIER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F1E |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F1D |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | D1E |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | D1D |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | FXE |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | FXD |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F3E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F1E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F1D |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | D1E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | D1D |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | FXE |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | FXD |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F3E |
| Power output listed is the composite for multi-channel operation. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application +U4tRnP19jsUCuvwFjLwCw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Fiplex Communications Inc 2101 NW 79th Ave. Miami, FL 33122 United States |
Date of Grant: 04/28/2017 Application Dated: 04/23/2017 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TDH7 |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | BI-DIRECTIONAL AMPLIFIER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F1E |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F1D |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | D1E |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | D1D |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | FXE |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | FXD |
| EF | 90 | 763.0 - 775.0 | 5.0 | Amp | F3E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F1E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F1D |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | D1E |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | D1D |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | FXE |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | FXD |
| EF | 90 | 793.0 - 805.0 | 0.25 | Amp | F3E |
| Power output listed is the composite for multi-channel operation. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: |