Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
758-768 MHzOriginal Equipment2019-06-18

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2019-06-18PDF 450.3 KB
Label Sample and Location DH7XID Label/Location Info2019-06-18PDF 554.8 KB
Test Setup PhotosTest Setup Photos2019-06-18PDF 975.2 KB
Test ReportTest Report2019-06-18PDF 4.5 MB
Part 90.203 Tuning Attestation StatementAttestation Statements2019-06-18PDF 38.5 KB
Warning Label Attestation StatementAttestation Statements2019-06-18PDF 67.3 KB
Confidential Request LetterCover Letter(s)2019-06-18PDF 882.2 KB
POACover Letter(s)2019-06-18PDF 67.3 KB
SISO Statement Cover LetterCover Letter(s)2019-06-18PDF 97 KB
MPE ReportRF Exposure Info2019-06-18PDF 505.6 KB
Tune-up ProcedureParts List/Tune Up Info2019-06-18PDF 12.3 KB
DH7 Signal Booster User Manual Metadata onlyUsers ManualPDF 5.7 MB
DH7S - PS800 & PS700 Signal Booster User Manual Metadata onlyUsers ManualPDF 4.6 MB
Internal Photos Metadata onlyInternal PhotosPDF 2.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 203.7 KB
Schematics Metadata onlySchematicsPDF 1.7 MB
DH7X Operational Description Metadata onlyOperational DescriptionPDF 337.5 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 317 KB

Application Information

Application IDQkvPP9FvIi+hF2S/tjDs4A==
Final Action Date2019-06-18
Application PurposeOriginal Equipment
Applicant FRN0005657499
ModelDH7X
Frequency Range758-768 MHz
Equipment ClassB9A - Part 90 Class A Industrial Booster (non-SMR)
Device Description700 MHz Industrial Booster
Responsible PartyRicardo de Goycoechea, General Manager, fiplex@signalgrp.com , 305-884-8991
Test FirmBruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com , 352-472-5500
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.

Applications

Application IDDatePurpose
QkvPP9FvIi+hF2S/tjDs4A==2019-06-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
758-768 MHz2.52Amp10M0W7D9
758-768 MHz2.52Amp5M00F9W9
758-768 MHz2.52Amp10M0F9W9
763-775 MHz2.52Amp4K00F3E9
763-775 MHz2.52Amp11K2F3E9
763-775 MHz2.52Amp16K0F3E9
763-775 MHz2.52Amp4K00F1E9
763-775 MHz2.52Amp4K00F1D9
763-775 MHz2.52Amp4K00F1W9
763-775 MHz2.52Amp8K30F1E9
763-775 MHz2.52Amp8K30F1D9
763-775 MHz2.52Amp8K30F1W9
763-775 MHz2.52Amp4K00F2D9
763-775 MHz2.52Amp8K30F2D9
763-775 MHz2.52Amp7K60FXE9
763-775 MHz2.52Amp7K60FXD9
763-775 MHz2.52Amp8K10F1E9
763-775 MHz2.52Amp8K10F1D9
763-775 MHz2.52Amp8K10F1W9
763-775 MHz2.52Amp9K80F1E9
763-775 MHz2.52Amp9K80F1D9
788-798 MHz2.52Amp10M0G7D9
788-798 MHz2.52Amp5M00D7W9
788-798 MHz2.52Amp10M0D7W9
788-798 MHz2.52Amp5M00W7D9
788-798 MHz2.52Amp10M0W7D9
788-798 MHz2.52Amp5M00F9W9
788-798 MHz2.52Amp10M0F9W9
788-798 MHz2.52Amp5M00G7D9
793-805 MHz0.25Amp4K00F3E9
793-805 MHz0.25Amp11K2F3E9
793-805 MHz0.25Amp16K0F3E9
793-805 MHz0.25Amp4K00F1E9
793-805 MHz0.25Amp4K00F1D9
793-805 MHz0.25Amp4K00F1W9
793-805 MHz0.25Amp8K30F1E9
793-805 MHz0.25Amp8K30F1D9
793-805 MHz0.25Amp8K30F1W9
793-805 MHz0.25Amp4K00F2D9
793-805 MHz0.25Amp8K30F2D9
793-805 MHz0.25Amp7K60FXE9
793-805 MHz0.25Amp7K60FXD9
793-805 MHz0.25Amp8K10F1E9
793-805 MHz0.25Amp8K10F1D9
793-805 MHz0.25Amp8K10F1W9
793-805 MHz0.25Amp9K80F1E9
793-805 MHz0.25Amp9K80F1D9

Grants

TCB Grant - Application QkvPP9FvIi+hF2S/tjDs4A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 06/18/2019

Application Dated: 06/18/2019
Fiplex Communications Inc
2101 NW 79th Ave.
Miami, FL 33122
 
Attention: Ricardo de Goycoechea , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P3TDH7X
Name of Grantee:  Fiplex Communications Inc
Equipment Class: Part 90 Class A Industrial Booster (non-SMR)
Notes: 700 MHz Industrial Booster
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 758.0  -  768.0 2.52  Amp 5M00G7D
90 758.0  -  768.0 2.52  Amp 10M0G7D
90 758.0  -  768.0 2.52  Amp 5M00D7W
90 758.0  -  768.0 2.52  Amp 10M0D7W
90 758.0  -  768.0 2.52  Amp 5M00W7D
90 758.0  -  768.0 2.52  Amp 10M0W7D
90 758.0  -  768.0 2.52  Amp 5M00F9W
90 758.0  -  768.0 2.52  Amp 10M0F9W
90 788.0  -  798.0 2.52  Amp 5M00G7D
90 788.0  -  798.0 2.52  Amp 10M0G7D
90 788.0  -  798.0 2.52  Amp 5M00D7W
90 788.0  -  798.0 2.52  Amp 10M0D7W
90 788.0  -  798.0 2.52  Amp 5M00W7D
90 788.0  -  798.0 2.52  Amp 10M0W7D
90 788.0  -  798.0 2.52  Amp 5M00F9W
90 788.0  -  798.0 2.52  Amp 10M0F9W
90 763.0  -  775.0 2.52  Amp 4K00F3E
90 763.0  -  775.0 2.52  Amp 11K2F3E
90 763.0  -  775.0 2.52  Amp 16K0F3E
90 763.0  -  775.0 2.52  Amp 4K00F1E
90 763.0  -  775.0 2.52  Amp 4K00F1D
90 763.0  -  775.0 2.52  Amp 4K00F1W
90 763.0  -  775.0 2.52  Amp 8K30F1E
90 763.0  -  775.0 2.52  Amp 8K30F1D
90 763.0  -  775.0 2.52  Amp 8K30F1W
90 763.0  -  775.0 2.52  Amp 4K00F2D
90 763.0  -  775.0 2.52  Amp 8K30F2D
90 763.0  -  775.0 2.52  Amp 7K60FXE
90 763.0  -  775.0 2.52  Amp 7K60FXD
90 763.0  -  775.0 2.52  Amp 8K10F1E
90 763.0  -  775.0 2.52  Amp 8K10F1D
90 763.0  -  775.0 2.52  Amp 8K10F1W
90 763.0  -  775.0 2.52  Amp 9K80F1E
90 763.0  -  775.0 2.52  Amp 9K80F1D
90 793.0  -  805.0 0.25  Amp 4K00F3E
90 793.0  -  805.0 0.25  Amp 11K2F3E
90 793.0  -  805.0 0.25  Amp 16K0F3E
90 793.0  -  805.0 0.25  Amp 4K00F1E
90 793.0  -  805.0 0.25  Amp 4K00F1D
90 793.0  -  805.0 0.25  Amp 4K00F1W
90 793.0  -  805.0 0.25  Amp 8K30F1E
90 793.0  -  805.0 0.25  Amp 8K30F1D
90 793.0  -  805.0 0.25  Amp 8K30F1W
90 793.0  -  805.0 0.25  Amp 4K00F2D
90 793.0  -  805.0 0.25  Amp 8K30F2D
90 793.0  -  805.0 0.25  Amp 7K60FXE
90 793.0  -  805.0 0.25  Amp 7K60FXD
90 793.0  -  805.0 0.25  Amp 8K10F1E
90 793.0  -  805.0 0.25  Amp 8K10F1D
90 793.0  -  805.0 0.25  Amp 8K10F1W
90 793.0  -  805.0 0.25  Amp 9K80F1E
90 793.0  -  805.0 0.25  Amp 9K80F1D

Class B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.

EAS Grant - Application QkvPP9FvIi+hF2S/tjDs4A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Fiplex Communications Inc
2101 NW 79th Ave.
Miami, FL 33122
United States
  Date of Grant: 06/18/2019

Application Dated: 06/18/2019
 
Attention: Ricardo de Goycoechea , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P3TDH7X
Name of Grantee:  Fiplex Communications Inc
Equipment Class: Part 90 Class A Industrial Booster (non-SMR)
Notes: 700 MHz Industrial Booster
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 758.0  -  768.0 2.52  Amp 5M00G7D
90 758.0  -  768.0 2.52  Amp 10M0G7D
90 758.0  -  768.0 2.52  Amp 5M00D7W
90 758.0  -  768.0 2.52  Amp 10M0D7W
90 758.0  -  768.0 2.52  Amp 5M00W7D
90 758.0  -  768.0 2.52  Amp 10M0W7D
90 758.0  -  768.0 2.52  Amp 5M00F9W
90 758.0  -  768.0 2.52  Amp 10M0F9W
90 788.0  -  798.0 2.52  Amp 5M00G7D
90 788.0  -  798.0 2.52  Amp 10M0G7D
90 788.0  -  798.0 2.52  Amp 5M00D7W
90 788.0  -  798.0 2.52  Amp 10M0D7W
90 788.0  -  798.0 2.52  Amp 5M00W7D
90 788.0  -  798.0 2.52  Amp 10M0W7D
90 788.0  -  798.0 2.52  Amp 5M00F9W
90 788.0  -  798.0 2.52  Amp 10M0F9W
90 763.0  -  775.0 2.52  Amp 4K00F3E
90 763.0  -  775.0 2.52  Amp 11K2F3E
90 763.0  -  775.0 2.52  Amp 16K0F3E
90 763.0  -  775.0 2.52  Amp 4K00F1E
90 763.0  -  775.0 2.52  Amp 4K00F1D
90 763.0  -  775.0 2.52  Amp 4K00F1W
90 763.0  -  775.0 2.52  Amp 8K30F1E
90 763.0  -  775.0 2.52  Amp 8K30F1D
90 763.0  -  775.0 2.52  Amp 8K30F1W
90 763.0  -  775.0 2.52  Amp 4K00F2D
90 763.0  -  775.0 2.52  Amp 8K30F2D
90 763.0  -  775.0 2.52  Amp 7K60FXE
90 763.0  -  775.0 2.52  Amp 7K60FXD
90 763.0  -  775.0 2.52  Amp 8K10F1E
90 763.0  -  775.0 2.52  Amp 8K10F1D
90 763.0  -  775.0 2.52  Amp 8K10F1W
90 763.0  -  775.0 2.52  Amp 9K80F1E
90 763.0  -  775.0 2.52  Amp 9K80F1D
90 793.0  -  805.0 0.25  Amp 4K00F3E
90 793.0  -  805.0 0.25  Amp 11K2F3E
90 793.0  -  805.0 0.25  Amp 16K0F3E
90 793.0  -  805.0 0.25  Amp 4K00F1E
90 793.0  -  805.0 0.25  Amp 4K00F1D
90 793.0  -  805.0 0.25  Amp 4K00F1W
90 793.0  -  805.0 0.25  Amp 8K30F1E
90 793.0  -  805.0 0.25  Amp 8K30F1D
90 793.0  -  805.0 0.25  Amp 8K30F1W
90 793.0  -  805.0 0.25  Amp 4K00F2D
90 793.0  -  805.0 0.25  Amp 8K30F2D
90 793.0  -  805.0 0.25  Amp 7K60FXE
90 793.0  -  805.0 0.25  Amp 7K60FXD
90 793.0  -  805.0 0.25  Amp 8K10F1E
90 793.0  -  805.0 0.25  Amp 8K10F1D
90 793.0  -  805.0 0.25  Amp 8K10F1W
90 793.0  -  805.0 0.25  Amp 9K80F1E
90 793.0  -  805.0 0.25  Amp 9K80F1D

Class B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.



Mail To: