FCC ID P3TDHS00-M
PS800 DIGITAL MASTER UNIT
by Fiplex Communications Inc
Grantee Code: P3T Product Code: DHS00M
Latest application date: 2017-11-17
FCC ID Device Details
| FCC ID | P3TDHS00-M |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | P3T |
| Product Code | DHS00M |
| Applicant Business | Fiplex Communications Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | PS800 DIGITAL MASTER UNIT |
| Test Firm | Timco Engineering, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 806-824 MHz | Original Equipment | 2017-11-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2017-11-17 | PDF 3.8 MB |
| External Photos | External Photos | 2017-11-17 | PDF 404.5 KB |
| Label Sample Location | ID Label/Location Info | 2017-11-17 | PDF 468.1 KB |
| Test Setup Photos | Test Setup Photos | 2017-11-17 | PDF 3.5 MB |
| Test Report | Test Report | 2017-11-17 | PDF 991.9 KB |
| Authority to Act as Agent | Cover Letter(s) | 2017-11-17 | PDF 48.6 KB |
| Confidential Letter | Cover Letter(s) | 2017-11-17 | PDF 860.4 KB |
| RF Exp. MPE Report | RF Exposure Info | 2017-11-17 | PDF 188.7 KB |
| Tune up Procedure | Parts List/Tune Up Info | 2017-11-17 | PDF 11.7 KB |
| Internal Photos Metadata only | Internal Photos | PDF 1 MB | |
| Block Diagram Metadata only | Block Diagram | PDF 185.7 KB | |
| Schematics Metadata only | Schematics | PDF 1.4 MB | |
| Operational Description Metadata only | Operational Description | PDF 183.3 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 148.2 KB |
Application Information
| Application ID | 2+R4iap/70lHExt6vLYxaA== |
|---|---|
| Final Action Date | 2017-11-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005657499 |
| Model | DHS00-M |
| Frequency Range | 806-824 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | PS800 DIGITAL MASTER UNIT |
| Responsible Party | Ricardo de Goycoechea, General Manager, fiplex@signalgrp.com |
| Test Firm | Bruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The single unit RF Exposure compliance for the device was based on maximum antenna gain 13dBi and 5W ERP compliance. This transmitter operates as a master unit as part of a system along with base station interface unit as described in this filing, and this application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 2+R4iap/70lHExt6vLYxaA== | 2017-11-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 2+R4iap/70lHExt6vLYxaA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 11/17/2017 Application Dated: 11/17/2017 |
| Fiplex Communications Inc |
| 2101 NW 79th Ave. |
| Miami, FL 33122 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TDHS00-M |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | PS800 DIGITAL MASTER UNIT |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F3E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F1W | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | G1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | D7W | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | D1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | FXE |
| Power output listed is conducted. The single unit RF Exposure compliance for the device was based on maximum antenna gain 13dBi and 5W ERP compliance. This transmitter operates as a master unit as part of a system along with base station interface unit as described in this filing, and this application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. |
EAS Grant - Application 2+R4iap/70lHExt6vLYxaA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Fiplex Communications Inc 2101 NW 79th Ave. Miami, FL 33122 United States |
Date of Grant: 11/17/2017 Application Dated: 11/17/2017 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TDHS00-M |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | PS800 DIGITAL MASTER UNIT |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F3E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | F1W | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | G1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | D7W | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | D1E | |
| 90 | 806.0 - 824.0 | 0.26 | Amp | FXE |
| Power output listed is conducted. The single unit RF Exposure compliance for the device was based on maximum antenna gain 13dBi and 5W ERP compliance. This transmitter operates as a master unit as part of a system along with base station interface unit as described in this filing, and this application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. |
| Mail To: |