FCC ID P3TDHSX

800 MHz Industrial Booster

by Fiplex Communications Inc

Grantee Code: P3T   Product Code: DHSX
Latest application date: 2019-06-19

FCC ID Device Details

FCC IDP3TDHSX
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeP3T
Product CodeDHSX
Applicant BusinessFiplex Communications Inc 🇺🇸
Related Domains signalgrp.com
Equipment Class800 MHz Industrial Booster
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-824 MHzOriginal Equipment2019-06-19

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2019-06-19PDF 518.4 KB
Label Sample and LocationID Label/Location Info2019-06-19PDF 683.1 KB
Test Setup PhotosTest Setup Photos2019-06-19PDF 976.1 KB
Test ReportTest Report2019-06-19PDF 4.2 MB
Tuning Attestation StatementAttestation Statements2019-06-19PDF 72.1 KB
Warning Label Attestation StatementAttestation Statements2019-06-19PDF 67.3 KB
Confidentiality Request LetterCover Letter(s)2019-06-19PDF 879.8 KB
Power of AttorneyCover Letter(s)2019-06-19PDF 100.8 KB
SISO StatementCover Letter(s)2019-06-19PDF 129.3 KB
MPE ReportRF Exposure Info2019-06-19PDF 505.6 KB
Tune Up ProcedureParts List/Tune Up Info2019-06-19PDF 21.4 KB
User Manual Metadata onlyUsers ManualPDF 4.7 MB
Internal Photos Metadata onlyInternal PhotosPDF 2.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 161.8 KB
Schematics Metadata onlySchematicsPDF 1.7 MB
Operational Description Metadata onlyOperational DescriptionPDF 338 KB
BOM Parts List Metadata onlyParts List/Tune Up InfoPDF 317 KB

Application Information

Application IDvenOmJ1pVs8XmisUWMeW3Q==
Final Action Date2019-06-19
Application PurposeOriginal Equipment
Applicant FRN0005657499
ModelDHSX
Frequency Range806-824 MHz
Equipment ClassB9A - Part 90 Class A Industrial Booster (non-SMR)
Device Description800 MHz Industrial Booster
Responsible PartyRicardo de Goycoechea, General Manager, fiplex@signalgrp.com , 305-884-8991
Test FirmBruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com , 352-472-5500
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.

Applications

Application IDDatePurpose
venOmJ1pVs8XmisUWMeW3Q==2019-06-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-824 MHz0.25Amp4K00F2D9
806-824 MHz0.25Amp8K30F2D9
806-824 MHz0.25Amp7K60FXE9
806-824 MHz0.25Amp7K60FXD9
806-824 MHz0.25Amp8K10F1E9
806-824 MHz0.25Amp8K10F1D9
806-824 MHz0.25Amp8K10F1W9
806-824 MHz0.25Amp9K80F1E9
806-824 MHz0.25Amp9K80F1D9
806-824 MHz0.25Amp4K00F1E9
806-824 MHz0.25Amp4K00F1D9
806-824 MHz0.25Amp4K00F1W9
806-824 MHz0.25Amp8K30F1E9
806-824 MHz0.25Amp8K30F1D9
806-824 MHz0.25Amp8K30F1W9
851-869 MHz2.52Amp4K00F3E9
851-869 MHz2.52Amp11K2F3E9
851-869 MHz2.52Amp16K0F3E9
851-869 MHz2.52Amp4K00F1E9
851-869 MHz2.52Amp4K00F1D9
851-869 MHz2.52Amp4K00F1W9
851-869 MHz2.52Amp8K30F1E9
851-869 MHz2.52Amp8K30F1D9
851-869 MHz2.52Amp8K30F1W9
851-869 MHz2.52Amp4K00F2D9
851-869 MHz2.52Amp8K30F2D9
851-869 MHz2.52Amp7K60FXE9
851-869 MHz2.52Amp7K60FXD9
851-869 MHz2.52Amp8K10F1E9
851-869 MHz2.52Amp8K10F1D9
851-869 MHz2.52Amp8K10F1W9
851-869 MHz2.52Amp9K80F1E9
851-869 MHz2.52Amp9K80F1D9

Grants

TCB Grant - Application venOmJ1pVs8XmisUWMeW3Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 06/19/2019

Application Dated: 06/19/2019
Fiplex Communications Inc
2101 NW 79th Ave.
Miami, FL 33122
 
Attention: Ricardo de Goycoechea , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P3TDHSX
Name of Grantee:  Fiplex Communications Inc
Equipment Class: Part 90 Class A Industrial Booster (non-SMR)
Notes: 800 MHz Industrial Booster
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 0.25  Amp 4K00F3E
90 806.0  -  824.0 0.25  Amp 11K2F3E
90 806.0  -  824.0 0.25  Amp 16K0F3E
90 806.0  -  824.0 0.25  Amp 4K00F1E
90 806.0  -  824.0 0.25  Amp 4K00F1D
90 806.0  -  824.0 0.25  Amp 4K00F1W
90 806.0  -  824.0 0.25  Amp 8K30F1E
90 806.0  -  824.0 0.25  Amp 8K30F1D
90 806.0  -  824.0 0.25  Amp 8K30F1W
90 806.0  -  824.0 0.25  Amp 4K00F2D
90 806.0  -  824.0 0.25  Amp 8K30F2D
90 806.0  -  824.0 0.25  Amp 7K60FXE
90 806.0  -  824.0 0.25  Amp 7K60FXD
90 806.0  -  824.0 0.25  Amp 8K10F1E
90 806.0  -  824.0 0.25  Amp 8K10F1D
90 806.0  -  824.0 0.25  Amp 8K10F1W
90 806.0  -  824.0 0.25  Amp 9K80F1E
90 806.0  -  824.0 0.25  Amp 9K80F1D
90 851.0  -  869.0 2.52  Amp 4K00F3E
90 851.0  -  869.0 2.52  Amp 11K2F3E
90 851.0  -  869.0 2.52  Amp 16K0F3E
90 851.0  -  869.0 2.52  Amp 4K00F1E
90 851.0  -  869.0 2.52  Amp 4K00F1D
90 851.0  -  869.0 2.52  Amp 4K00F1W
90 851.0  -  869.0 2.52  Amp 8K30F1E
90 851.0  -  869.0 2.52  Amp 8K30F1D
90 851.0  -  869.0 2.52  Amp 8K30F1W
90 851.0  -  869.0 2.52  Amp 4K00F2D
90 851.0  -  869.0 2.52  Amp 8K30F2D
90 851.0  -  869.0 2.52  Amp 7K60FXE
90 851.0  -  869.0 2.52  Amp 7K60FXD
90 851.0  -  869.0 2.52  Amp 8K10F1E
90 851.0  -  869.0 2.52  Amp 8K10F1D
90 851.0  -  869.0 2.52  Amp 8K10F1W
90 851.0  -  869.0 2.52  Amp 9K80F1E
90 851.0  -  869.0 2.52  Amp 9K80F1D

Class B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.

EAS Grant - Application venOmJ1pVs8XmisUWMeW3Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Fiplex Communications Inc
2101 NW 79th Ave.
Miami, FL 33122
United States
  Date of Grant: 06/19/2019

Application Dated: 06/19/2019
 
Attention: Ricardo de Goycoechea , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P3TDHSX
Name of Grantee:  Fiplex Communications Inc
Equipment Class: Part 90 Class A Industrial Booster (non-SMR)
Notes: 800 MHz Industrial Booster
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 0.25  Amp 4K00F3E
90 806.0  -  824.0 0.25  Amp 11K2F3E
90 806.0  -  824.0 0.25  Amp 16K0F3E
90 806.0  -  824.0 0.25  Amp 4K00F1E
90 806.0  -  824.0 0.25  Amp 4K00F1D
90 806.0  -  824.0 0.25  Amp 4K00F1W
90 806.0  -  824.0 0.25  Amp 8K30F1E
90 806.0  -  824.0 0.25  Amp 8K30F1D
90 806.0  -  824.0 0.25  Amp 8K30F1W
90 806.0  -  824.0 0.25  Amp 4K00F2D
90 806.0  -  824.0 0.25  Amp 8K30F2D
90 806.0  -  824.0 0.25  Amp 7K60FXE
90 806.0  -  824.0 0.25  Amp 7K60FXD
90 806.0  -  824.0 0.25  Amp 8K10F1E
90 806.0  -  824.0 0.25  Amp 8K10F1D
90 806.0  -  824.0 0.25  Amp 8K10F1W
90 806.0  -  824.0 0.25  Amp 9K80F1E
90 806.0  -  824.0 0.25  Amp 9K80F1D
90 851.0  -  869.0 2.52  Amp 4K00F3E
90 851.0  -  869.0 2.52  Amp 11K2F3E
90 851.0  -  869.0 2.52  Amp 16K0F3E
90 851.0  -  869.0 2.52  Amp 4K00F1E
90 851.0  -  869.0 2.52  Amp 4K00F1D
90 851.0  -  869.0 2.52  Amp 4K00F1W
90 851.0  -  869.0 2.52  Amp 8K30F1E
90 851.0  -  869.0 2.52  Amp 8K30F1D
90 851.0  -  869.0 2.52  Amp 8K30F1W
90 851.0  -  869.0 2.52  Amp 4K00F2D
90 851.0  -  869.0 2.52  Amp 8K30F2D
90 851.0  -  869.0 2.52  Amp 7K60FXE
90 851.0  -  869.0 2.52  Amp 7K60FXD
90 851.0  -  869.0 2.52  Amp 8K10F1E
90 851.0  -  869.0 2.52  Amp 8K10F1D
90 851.0  -  869.0 2.52  Amp 8K10F1W
90 851.0  -  869.0 2.52  Amp 9K80F1E
90 851.0  -  869.0 2.52  Amp 9K80F1D

Class B Signal Booster. Professional installation required. Power output listed is conducted. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antennas used for this transmitter is to be fixed-mounted on indoor / outdoor permanent structures, and may not have gain exceeding 1.0 dBi (DL) or +13 dBi (UL). A minimum separation of 20 cm is required between the antennas and any person. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems.



Mail To: