FCC ID P3TTXPA220
MTA-PTC POWER AMPLIFIER
by Fiplex Communications Inc
Grantee Code: P3T Product Code: TXPA220
Latest application date: 2018-11-14
FCC ID Device Details
| FCC ID | P3TTXPA220 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | P3T |
| Product Code | TXPA220 |
| Applicant Business | Fiplex Communications Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | MTA-PTC POWER AMPLIFIER |
| Test Firm | Timco Engineering, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 218-219 MHz | Original Equipment | 2018-11-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2018-11-14 | PDF 412.7 KB |
| External Photos | External Photos | 2018-11-14 | PDF 241.7 KB |
| Label Info | ID Label/Location Info | 2018-11-14 | PDF 155.6 KB |
| Test Setup Photos | Test Setup Photos | 2018-11-14 | PDF 435.9 KB |
| Test Report | Test Report | 2018-11-14 | PDF 1.7 MB |
| Agent Authorization Letter | Cover Letter(s) | 2018-11-14 | PDF 11.6 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2018-11-14 | PDF 860.6 KB |
| MPE Report | RF Exposure Info | 2018-11-14 | PDF 385.5 KB |
| Tune Up Procedure | Parts List/Tune Up Info | 2018-11-14 | PDF 10.6 KB |
| Internal Photos Metadata only | Internal Photos | PDF 313.8 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 192.3 KB | |
| Schematics Metadata only | Schematics | PDF 740 KB | |
| Operational Description Metadata only | Operational Description | PDF 177 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 33.5 KB |
Application Information
| Application ID | vOpZzLXw07najBQWtS4b2g== |
|---|---|
| Final Action Date | 2018-11-14 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005657499 |
| Model | TXPA220 |
| Frequency Range | 218-219 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | MTA-PTC POWER AMPLIFIER |
| Responsible Party | Ricardo de Goycoechea, General Manager, fiplex@signalgrp.com |
| Test Firm | Bruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is ERP. The maximum antenna gain for this device as reported to the FCC is 2.2dBi. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 1.15 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| vOpZzLXw07najBQWtS4b2g== | 2018-11-14 | Original Equipment |
Grants
TCB Grant - Application vOpZzLXw07najBQWtS4b2g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 11/14/2018 Application Dated: 10/15/2018 |
| Fiplex Communications Inc |
| 2101 NW 79th Ave. |
| Miami, FL 33122 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TTXPA220 |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Amplifier |
| Notes: | MTA-PTC POWER AMPLIFIER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95 | 218.0 - 219.0 | 20.0 | Amp | 8K12F1D |
| Output power listed is ERP. The maximum antenna gain for this device as reported to the FCC is 2.2dBi. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 1.15 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application vOpZzLXw07najBQWtS4b2g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Fiplex Communications Inc 2101 NW 79th Ave. Miami, FL 33122 United States |
Date of Grant: 11/14/2018 Application Dated: 10/15/2018 |
| Attention: Ricardo de Goycoechea , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | P3TTXPA220 |
| Name of Grantee: | Fiplex Communications Inc |
| Equipment Class: | Amplifier |
| Notes: | MTA-PTC POWER AMPLIFIER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95 | 218.0 - 219.0 | 20.0 | Amp | 8K12F1D |
| Output power listed is ERP. The maximum antenna gain for this device as reported to the FCC is 2.2dBi. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 1.15 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |