FCC ID P4M-APT230

CDMA Personal Tracking Device

by AnyDATA Corporation

Grantee Code: P4M   Product Code: APT230
Latest application date: 2013-11-25

FCC ID Device Details

FCC IDP4M-APT230
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeP4M
Product CodeAPT230
Applicant BusinessAnyDATA Corporation 🇺🇸
Related Domains anydata.com
Equipment ClassCDMA Personal Tracking Device
Test FirmBay Area Compliance Laboratories Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2013-11-25

Exhibits

DocumentTypeAvailableFile
User GuideUsers Manual2013-11-25PDF 1.9 MB
Int PhotosInternal Photos2013-11-25PDF 268.3 KB
Ext PhotosExternal Photos2013-11-25PDF 315.3 KB
FCC ID LabelID Label/Location Info2013-11-25PDF 39.9 KB
Setup PhotosTest Setup Photos2013-11-25PDF 200.7 KB
Test ReportTest Report2013-11-25PDF 395.3 KB
Confidentiality LetterCover Letter(s)2013-11-25PDF 910.5 KB
POACover Letter(s)2013-11-25PDF 958.9 KB
RF ExposureRF Exposure Info2013-11-25PDF 3.6 MB

Application Information

Application IDvN0Tv7GG91EQE8n1N6s56Q==
Final Action Date2013-11-25
Application PurposeOriginal Equipment
Applicant FRN0005865225
Model-APT230
Frequency Range824.7-848.31 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionCDMA Personal Tracking Device
Responsible PartyDoug KWON, Director of Operation, dougkwon@anydata.com , 1-949-900-6040
Test FirmKaveh Moraghebi, Bay Area Compliance Laboratories Corporation, kaveh@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for body-worn operation is based on a separation distance of 10mm between the unit and the body of the user with the accessory clip specified in this filing, for speak mode operation is based on a conservative exposure condition with the separation distance of 15mm between the unit and the mouth of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values for speak mode and body-worn use conditions are: 0.96 W/kg and 1.55 W/kg, respectively.

Applications

Application IDDatePurpose
vN0Tv7GG91EQE8n1N6s56Q==2013-11-25Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.2062.5ppm1M27F9W22H
1851.25-1908.75 MHz0.1792.5ppm1M28F9W24E

Grants

TCB Grant - Application vN0Tv7GG91EQE8n1N6s56Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 11/25/2013

Application Dated: 11/25/2013
AnyDATA Corporation
5 Oldfield
Irvine, CA 92618
 
Attention: Doug KWON , Director of Operation

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4M-APT230
Name of Grantee:  AnyDATA Corporation
Equipment Class: PCS Licensed Transmitter
Notes: CDMA Personal Tracking Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.206 2.5  PM 1M27F9W
24E 1851.25  -  1908.75 0.179 2.5  PM 1M28F9W

Output power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for body-worn operation is based on a separation distance of 10mm between the unit and the body of the user with the accessory clip specified in this filing, for speak mode operation is based on a conservative exposure condition with the separation distance of 15mm between the unit and the mouth of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values for speak mode and body-worn use conditions are: 0.96 W/kg and 1.55 W/kg, respectively.

EAS Grant - Application vN0Tv7GG91EQE8n1N6s56Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

AnyDATA Corporation
5 Oldfield
Irvine, CA 92618
United States
  Date of Grant: 11/25/2013

Application Dated: 11/25/2013
 
Attention: Doug KWON , Director of Operation

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4M-APT230
Name of Grantee:  AnyDATA Corporation
Equipment Class: PCS Licensed Transmitter
Notes: CDMA Personal Tracking Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.206 2.5  PM 1M27F9W
24E 1851.25  -  1908.75 0.179 2.5  PM 1M28F9W

Output power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for body-worn operation is based on a separation distance of 10mm between the unit and the body of the user with the accessory clip specified in this filing, for speak mode operation is based on a conservative exposure condition with the separation distance of 15mm between the unit and the mouth of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values for speak mode and body-worn use conditions are: 0.96 W/kg and 1.55 W/kg, respectively.



Mail To: