FCC ID P4Q-N399M

Navigation Device

by Mitac Digital Technology Corporation

Grantee Code: P4Q   Product Code: N399M
Latest application date: 2012-06-28

FCC ID Device Details

FCC IDP4Q-N399M
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeP4Q
Product CodeN399M
Applicant BusinessMitac Digital Technology Corporation 🇹🇼
Related Domains mic.com.tw
Equipment ClassNavigation Device
Test FirmInternational Standards Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2012-06-28
2402-2480 MHzOriginal Equipment2012-06-28

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2012-12-15PDF 1.6 MB
user manualUsers Manual2012-12-15PDF 1.6 MB
Int. photoInternal Photos2012-12-15PDF 545.3 KB
Ext. photoExternal Photos2012-12-15PDF 460.2 KB
LableID Label/Location Info2012-06-28PDF 82.7 KB
labelID Label/Location Info2012-06-28PDF 82.7 KB
SAR setup photosTest Setup Photos2012-12-15PDF 217.2 KB
test setup photoTest Setup Photos2012-12-15PDF 346.3 KB
test setup photosTest Setup Photos2012-12-15PDF 346.3 KB
ProbleTest Report2012-06-28PDF 175 KB
SAR Measurment dataTest Report2012-06-28PDF 1.6 MB
SAR reportTest Report2012-06-28PDF 638.4 KB
System performance checkTest Report2012-06-28PDF 75.5 KB
dipoleTest Report2012-06-28PDF 472.3 KB
test reportTest Report2012-06-28PDF 1.9 MB
test reportTest Report2012-06-28PDF 2.1 MB
Confi. letterCover Letter(s)2012-06-28PDF 330.6 KB
DoACover Letter(s)2012-06-28PDF 33.4 KB
DoCCover Letter(s)2012-06-28PDF 85.9 KB

Application Information

Application IDo0RHe0/znoZGleE9Ljfhww==
Final Action Date2012-06-28
Application PurposeOriginal Equipment
Applicant FRN0022217111
Model-N399M
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionNavigation Device
Responsible PartyRuey-Yuan Chen, Director, Ruey-Yuan.Chen@mic.com.tw , 886-2-2652-5888
Technical ContactVincent Su, International Stantards Laboratory, vincent_WH_su@isl.com.tw
Test FirmBert Chen, International Standards Laboratory, bert_chen@isl.com.tw , 886-3-4071718
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/15/2012
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported Body-worn SAR value is: 1.265W/Kg. This device has a 20 MHz bandwidth mode.

Applications

Application IDDatePurpose
o0RHe0/znoZGleE9Ljfhww==2012-06-28Original Equipment
0OE9DNdU0A31MyxtcKPGHA==2012-06-28Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.001400015CCC
2412-2462 MHz0.171000015CCC

Grants

TCB Grant - Application o0RHe0/znoZGleE9Ljfhww==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 06/28/2012

Application Dated: 06/27/2012
Mitac International Corporation
Building B, No.209, Sec.1, Nan Gang Rd., Nan Gang
Taipei, 11568
Taiwan
 
Attention: Ruey-Yuan Chen , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4Q-N399M
Name of Grantee:  Mitac International Corporation
Equipment Class: Digital Transmission System
Notes: Navigation Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.171  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported Body-worn SAR value is: 1.265W/Kg.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application o0RHe0/znoZGleE9Ljfhww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Mitac International Corporation
Building B, No.209, Sec.1, Nan Gang Rd., Nan Gang
Taipei, 11568
Taiwan
  Date of Grant: 06/28/2012

Application Dated: 06/27/2012
 
Attention: Ruey-Yuan Chen , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4Q-N399M
Name of Grantee:  Mitac International Corporation
Equipment Class: Digital Transmission System
Notes: Navigation Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.171  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported Body-worn SAR value is: 1.265W/Kg.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 0OE9DNdU0A31MyxtcKPGHA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 06/28/2012

Application Dated: 06/27/2012
Mitac International Corporation
Building B, No.209, Sec.1, Nan Gang Rd., Nan Gang
Taipei, 11568
Taiwan
 
Attention: Ruey-Yuan Chen , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4Q-N399M
Name of Grantee:  Mitac International Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Navigation Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0014  

Power output listed is conducted. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 0OE9DNdU0A31MyxtcKPGHA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Mitac International Corporation
Building B, No.209, Sec.1, Nan Gang Rd., Nan Gang
Taipei, 11568
Taiwan
  Date of Grant: 06/28/2012

Application Dated: 06/27/2012
 
Attention: Ruey-Yuan Chen , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  P4Q-N399M
Name of Grantee:  Mitac International Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Navigation Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0014  

Power output listed is conducted. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: