FCC ID PA4-M750
Digital Camera
by Eastman Kodak Company
Grantee Code: PA4 Product Code: M750
Latest application date: 2011-12-13
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2011-12-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2012-06-10 | PDF 4 MB |
| internal photos | Internal Photos | 2012-06-10 | PDF 2.3 MB |
| external photos | External Photos | 2012-06-10 | PDF 2 MB |
| Label | ID Label/Location Info | 2011-12-13 | PDF 84.7 KB |
| sar test setup photos | Test Setup Photos | 2012-06-10 | PDF 444.7 KB |
| tes setup phoots | Test Setup Photos | 2012-06-10 | PDF 502.4 KB |
| Test Report | Test Report | 2011-12-13 | PDF 1.4 MB |
| Ad hoc letter | Cover Letter(s) | 2011-12-13 | PDF 791.6 KB |
| DOC letter | Cover Letter(s) | 2011-12-13 | PDF 830.1 KB |
| LTC Reuqest | Cover Letter(s) | 2011-12-13 | PDF 472.6 KB |
| PoA | Cover Letter(s) | 2011-12-13 | PDF 933.6 KB |
| SAR Report | RF Exposure Info | 2011-12-13 | PDF 4.1 MB |
Application Information
| Application ID | Hd9VlQqqDKeEeW1rnHxQ4g== |
|---|---|
| Final Action Date | 2011-12-13 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003414208 |
| Model | -M750 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Digital Camera |
| Responsible Party | Charles H. Hasenauer, Sr. EMC and Product Safety Engineer, charles.hasenauer@kodak.com |
| Agent | Leo Leo Leo, Sporton Int., leohuang@sporton.com.tw |
| Test Firm | Alex Chen, Sporton International Inc., alex@sporton.com.tw |
| TCB Email | Brandhorst.dirk@phoenix-testlab.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 06/10/2012 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power listed is peak conducted. Device is operating in a 1T1R Spatial Multiplexing MIMO configuration as described in this filing. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance for body-worn operating conditions is restricted to accessories that have no metallic component in the assembly and must provide at least 1 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.041 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Hd9VlQqqDKeEeW1rnHxQ4g== | 2011-12-13 | Original Equipment |
Grants
TCB Grant - Application Hd9VlQqqDKeEeW1rnHxQ4g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 12/13/2011 Application Dated: 12/13/2011 |
| Eastman Kodak Company |
| 343 State St. |
| Rochester, NY 14650 |
| Attention: Charles Hasenauer , Sr. EMC and Product Safety Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PA4-M750 |
| Name of Grantee: | Eastman Kodak Company |
| Equipment Class: | Digital Transmission System |
| Notes: | Digital Camera |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.116 |
| Output Power listed is peak conducted. Device is operating in a 1T1R Spatial Multiplexing MIMO configuration as described in this filing. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance for body-worn operating conditions is restricted to accessories that have no metallic component in the assembly and must provide at least 1 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.041 W/kg. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application Hd9VlQqqDKeEeW1rnHxQ4g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Eastman Kodak Company 343 State St. Rochester, NY 14650 United States |
Date of Grant: 12/13/2011 Application Dated: 12/13/2011 |
| Attention: Charles Hasenauer , Sr. EMC and Product Safety Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PA4-M750 |
| Name of Grantee: | Eastman Kodak Company |
| Equipment Class: | Digital Transmission System |
| Notes: | Digital Camera |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.116 |
| Output Power listed is peak conducted. Device is operating in a 1T1R Spatial Multiplexing MIMO configuration as described in this filing. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance for body-worn operating conditions is restricted to accessories that have no metallic component in the assembly and must provide at least 1 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.041 W/kg. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |