FCC ID PBJV284-A

Subscriber WMU

by Vyyo

Grantee Code: PBJ   Product Code: V284A
Latest application date: 2006-01-23

FCC ID Device Details

FCC IDPBJV284-A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePBJ
Product CodeV284A
Applicant BusinessVyyo 🇺🇸
Related Domains vyyo.com tncokenias.org
Equipment ClassSubscriber WMU
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
776.075-776.925 MHzClass II permissive change or modification of presently authorized equipment2006-01-23
776.075-776.925 MHzOriginal Equipment2005-11-21

Exhibits

DocumentTypeAvailableFile
User Manual RevisedUsers Manual2005-11-21PDF 138.2 KB
Internal Photos RevisedInternal Photos2005-11-21PDF 203.9 KB
External PhotosExternal Photos2005-11-21PDF 428.1 KB
Label LocationID Label/Location Info2005-11-21PDF 176.1 KB
Block DiagramBlock Diagram2005-11-21PDF 55.4 KB
Additional Test PhotosTest Setup Photos2005-11-21PDF 118 KB
Test PhotosTest Setup Photos2005-11-21PDF 355.9 KB
test report out of band with new occ bwTest Report2006-01-23PDF 855.3 KB
Test Report Revision 2Test Report2005-11-21PDF 1.2 MB
Additional bandwidthsCover Letter(s)2006-01-23PDF 94.5 KB
Request to remove confidentialityCover Letter(s)2006-01-23PDF 81.7 KB
description of changeCover Letter(s)2006-01-23PDF 82.2 KB
CommentsCover Letter(s)2005-11-21PDF 58.1 KB
Confidentiality LetterCover Letter(s)2005-11-21PDF 55.7 KB
ResponseCover Letter(s)2005-11-21PDF 13.3 KB
Tune Up ProcedureParts List/Tune Up Info2005-11-21PDF 84 KB

Application Information

Application IDYqCuBoY9kh9GkioHYM7q3A==
Final Action Date2006-01-23
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0004058624
ModelV284-A
Frequency Range776.075-776.925 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionSubscriber WMU
Responsible PartyDr. Mike Ritter, VP Marketing, mritter@vyyo.com , 650-319 4037
AgentThomas Thomas Thomas, T.N. Cokenias Consulting, tom@tncokenias.org , 650 726 1263
Technical ContactThomas N. Cokenias, T.N. Cokenias Consulting, tom@tncokenias.org , 650 726 1263
Non-Technical ContactThomas N. Cokenias, T.N. Cokenias Consulting, tom@tncokenias.org , 650 726 1263
Test FirmAlexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com , 972-4628-8001
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis Permissive Change/Modification was originally issued on 01/18/2006.

Applications

Application IDDatePurpose
YqCuBoY9kh9GkioHYM7q3A==2006-01-23Class II permissive change or modification of presently authorized equipment
Zf6MyNq686tY97kcIP3EjQ==2005-11-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
776.075-776.925 MHz0.2471351Hz110KD1W272
776.075-776.925 MHz0.2471351Hz112KG1W272
776.075-776.925 MHz0.2471351Hz200KD1W272
776.075-776.925 MHz0.2471351Hz200KG1W272
776.075-776.925 MHz0.2471351Hz325KD1W272
776.075-776.925 MHz0.2471351Hz325KG1W272
776.075-776.925 MHz0.2471351Hz400KD1W272
776.075-776.925 MHz0.2471351Hz400KG1W272

Grants

TCB Grant - Application Zf6MyNq686tY97kcIP3EjQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 11/21/2005

Application Dated: 11/21/2005
Vyyo
4015 Miranda Avenue
Palo Alto, CA 94304
 
Attention: Dr. Mike Ritter , VP Marketing

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PBJV284-A
Name of Grantee:  Vyyo
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Subscriber WMU
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 27 776.075  -  776.925 0.247 1351.0  Hz 110KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 112KG1W

Power Output listed is Conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 0.25 W and the peak radiated output power must not exceed 5.54 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application Zf6MyNq686tY97kcIP3EjQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Vyyo
4015 Miranda Avenue
Palo Alto, CA 94304
United States
  Date of Grant: 11/21/2005

Application Dated: 11/21/2005
 
Attention: Dr. Mike Ritter , VP Marketing

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PBJV284-A
Name of Grantee:  Vyyo
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Subscriber WMU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 27 776.075  -  776.925 0.247 1351.0  Hz 110KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 112KG1W

Power Output listed is Conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 0.25 W and the peak radiated output power must not exceed 5.54 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application YqCuBoY9kh9GkioHYM7q3A==

This application does not exist.

EAS Grant - Application YqCuBoY9kh9GkioHYM7q3A==

Mail To:
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Vyyo
4015 Miranda Avenue
Palo Alto, CA 94304
United States
  Date of Grant: 01/23/2006

Application Dated: 12/27/2005
 
Attention: Dr. Mike Ritter , VP Marketing

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PBJV284-A
Name of Grantee:  Vyyo
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Subscriber WMU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 27 776.075  -  776.925 0.247 1351.0  Hz 110KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 112KG1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 200KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 200KG1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 325KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 325KG1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 400KD1W
20 27 776.075  -  776.925 0.247 1351.0  Hz 400KG1W

Power Output listed is Conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 0.25 W and the peak radiated output power must not exceed 5.54 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.

This Permissive Change/Modification was originally issued on 01/18/2006.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: