FCC ID PC6EK-001B

CDMA Cellular Modem

by Growell Telecom Co., Ltd.

Grantee Code: PC6   Product Code: EK001B
Latest application date: 2002-02-14

FCC ID Device Details

FCC IDPC6EK-001B
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePC6
Product CodeEK001B
Applicant BusinessGrowell Telecom Co., Ltd. 🇰🇷
Related Domains yisotel.com pctestlab.com
Equipment ClassCDMA Cellular Modem
Test FirmPCTEST Engineering Laboratory, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2002-02-14

Exhibits

DocumentTypeAvailableFile
Users Manual and Warning PageUsers Manual2002-02-14PDF 2.5 MB
Internal PhotographsInternal Photos2002-02-14PDF 1.7 MB
External PhotographsExternal Photos2002-02-14PDF 912 KB
Amendment FCC ID LabelID Label/Location Info2002-02-14PDF 26.4 KB
FCC ID Label and LocationID Label/Location Info2002-02-14PDF 48.5 KB
Test Set Up PhotographsTest Setup Photos2002-02-14PDF 555.2 KB
Test PlotsTest Report2002-02-14PDF 368.4 KB
Test ReportTest Report2002-02-14PDF 843.3 KB
Attestation StatementsAttestation Statements2002-02-14PDF 127.2 KB
Cover LettterCover Letter(s)2002-02-14PDF 20.3 KB
MPE DataRF Exposure Info2002-02-14PDF 8.4 KB
Block Diagrams Metadata onlyBlock DiagramPDF 33.4 KB
Schematics Metadata onlySchematicsPDF 541.5 KB
Operational and Circuit Description and Antenna Specs Metadata onlyOperational DescriptionPDF 244.3 KB
Parts Lists and Tune Up Metadata onlyParts List/Tune Up InfoPDF 805.2 KB

Application Information

Application IDgNKC2aO6KnZk5yofPtQivA==
Final Action Date2002-02-14
Application PurposeOriginal Equipment
Applicant FRN0005911086
ModelEK-001B
Frequency Range824.7-848.31 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionCDMA Cellular Modem
Responsible PartySung H Lee, Senior Engineer, Ishyun@yisotel.com , 82-2-576-6996
AgentRandy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Non-Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Test FirmRandy Ortanez, PCTEST Engineering Laboratory, Inc., ro@pctestlab.com , 410-290-6652
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsAntenna gain is not to exceed 0 dBi. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
gNKC2aO6KnZk5yofPtQivA==2002-02-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.25300002.5000000000ppm1M25F9W22.901(d)

Grants

TCB Grant - Application gNKC2aO6KnZk5yofPtQivA==

This application does not exist.

EAS Grant - Application gNKC2aO6KnZk5yofPtQivA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Growell Telecom Co., Ltd.
319-8 Gasan-dong, Geumcheon-ku
Seoul, 153-802
South Korea
  Date of Grant: 02/14/2002

Application Dated: 12/18/2001
 
Attention: Sung Lee , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PC6EK-001B
Name of Grantee:  Growell Telecom Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: CDMA Cellular Modem
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22.901(d) 824.7  -  848.31 0.253 2.5  PM 1M25F9W

Power is ERP.

Antenna gain is not to exceed 0 dBi. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.