FCC ID PD7HHP
CDMA Handset
by Philips Cellular Americas R&D; (CARD) Center
Grantee Code: PD7 Product Code: HHP
Latest application date: 2001-06-07
FCC ID Device Details
| FCC ID | PD7HHP |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PD7 |
| Product Code | HHP |
| Applicant Business | Philips Cellular Americas R&D; (CARD) Center 🇺🇸 |
| Related Domains | |
| Equipment Class | CDMA Handset |
| Test Firm | Nemko Dallas, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.04-848.97 MHz | Original Equipment | 2001-06-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Guide with exposure warnings | Users Manual | 2001-06-07 | PDF 263.9 KB |
| User Manual (RF exposure page only ?) | Users Manual | 2001-06-07 | PDF 12.1 KB |
| Equipment Photos | Internal Photos | 2001-06-07 | PDF 216.9 KB |
| External Photos | External Photos | 2001-06-07 | PDF 216.9 KB |
| Label format and location | ID Label/Location Info | 2001-06-07 | PDF 39.7 KB |
| blockdiagram | Block Diagram | 2001-06-07 | PDF 23 KB |
| Schematic1 | Schematics | 2001-06-07 | PDF 43.1 KB |
| Schematic2 | Schematics | 2001-06-07 | PDF 34.3 KB |
| Schematic3 | Schematics | 2001-06-07 | PDF 53.4 KB |
| Schematic4 | Schematics | 2001-06-07 | PDF 32.5 KB |
| Schematic5 | Schematics | 2001-06-07 | PDF 56.1 KB |
| Schematic6 | Schematics | 2001-06-07 | PDF 29.2 KB |
| Schematic7 | Schematics | 2001-06-07 | PDF 44.9 KB |
| Circuit Description | Operational Description | 2001-06-07 | PDF 237.6 KB |
| setup photos | Test Setup Photos | 2001-06-07 | PDF 192.1 KB |
| Test Report | Test Report | 2001-06-07 | PDF 482.4 KB |
| additional erp data | Test Report | 2001-06-07 | PDF 12.4 KB |
| IS95 Compatibility | Attestation Statements | 2001-06-07 | PDF 2.6 KB |
| agent letter | Cover Letter(s) | 2001-06-07 | PDF 18 KB |
| request for confidentiality | Cover Letter(s) | 2001-06-07 | PDF 22.4 KB |
| SAR Report | RF Exposure Info | 2001-06-07 | PDF 2.4 MB |
| Tuneup Info | Parts List/Tune Up Info | 2001-06-07 | PDF 2.7 KB |
| schematic10 Metadata only | Schematics | PDF 37.6 KB | |
| schematic11 Metadata only | Schematics | PDF 35.3 KB | |
| schematic12 Metadata only | Schematics | PDF 31 KB | |
| schematic8 Metadata only | Schematics | PDF 113.3 KB | |
| schematic9 Metadata only | Schematics | PDF 35.6 KB |
Application Information
| Application ID | 411zcBAVrfkYvIB7wVAllQ== |
|---|---|
| Final Action Date | 2001-06-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 9999999999 |
| Model | HHP |
| Frequency Range | 824.04-848.97 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | CDMA Handset |
| Responsible Party | John Kajander, RF and System Engineer, john.kajander@philips.com |
| Agent | Tom Tom Tom, KTL Dallas, Inc., ttidwell@icomply.com |
| Technical Contact | Tom Tidwell, KTL Dallas, Inc., ttidwell@icomply.com |
| Non-Technical Contact | Alma Torres, KTL Dallas, Inc., atorres@icomply.com |
| Test Firm | Michael Cantwell, Nemko Dallas, Inc., @., 972-436-9600 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device, including its antenna, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.08 W/kg; Body-worn: 0.68 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 411zcBAVrfkYvIB7wVAllQ== | 2001-06-07 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 411zcBAVrfkYvIB7wVAllQ==
This application does not exist.
EAS Grant - Application 411zcBAVrfkYvIB7wVAllQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Cellular Americas R&D (CARD) Center 2140 Lake Park Blvd. Suite 200 Richardson, TX 75080 United States |
Date of Grant: 06/07/2001 Application Dated: 01/23/2001 |
| Attention: John Kajander , RF and System Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PD7HHP |
| Name of Grantee: | Philips Cellular Americas R&D (CARD) Center |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | CDMA Handset |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22.901(d) | 824.04 - 848.97 | 0.133 | 100.0 Hz | 1M25F9W |
| Output is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device, including its antenna, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.08 W/kg; Body-worn: 0.68 W/kg. |
| Mail To: |